ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf

上传人:arrownail386 文档编号:527673 上传时间:2018-12-04 格式:PDF 页数:30 大小:790.99KB
下载 相关 举报
ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第1页
第1页 / 共30页
ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第2页
第2页 / 共30页
ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第3页
第3页 / 共30页
ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第4页
第4页 / 共30页
ASTM E84-2017a red 8125 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第5页
第5页 / 共30页
亲,该文档总共30页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E84 17E84 17a An American National StandardStandard Test Method forSurface Burning Characteristics of Building Materials1This standard is issued under the fixed designation E84; the number immediately following the designation indicates the year of originaladoption or, in the case of re

2、vision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This fire-testr

3、esponse standard for the comparative surface burning behavior of building materials is applicable to exposedsurfaces such as walls and ceilings. The test is conducted with the specimen in the ceiling position with the surface to be evaluatedexposed face down to the ignition source. The material, pro

4、duct, or assembly shall be capable of being mounted in the test positionduring the test. Thus, the specimen shall either be self-supporting by its own structural quality, held in place by added supportsalong the test surface, or secured from the back side.1.2 The purpose of this test method is to de

5、termine the relative burning behavior of the material by observing the flame spreadalong the specimen. Flame spread and smoke developed index are reported. However, there is not necessarily a relationshipbetween these two measurements.1.3 The use of supporting materials on the underside of the test

6、specimen has the ability to lower the flame spread index fromthose which might be obtained if the specimen could be tested without such support. These test results do not necessarily relateto indices obtained by testing materials without such support.1.4 Testing of materials that melt, drip, or dela

7、minate to such a degree that the continuity of the flame front is destroyed, resultsin low flame spread indices that do not relate directly to indices obtained by testing materials that remain in place.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in pare

8、ntheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.6 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes,excluding those in tables and figures, shall not be cons

9、idered as requirements of the standard.1.7 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials,p

10、roducts, or assemblies under actual fire conditions.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and de

11、termine theapplicability of regulatory limitations prior to use.1.9 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting thesetests.1.10 This international standard was developed in accordance with internationally recognized principles

12、on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A390 Specification for Zinc-Coated (Galv

13、anized) Steel Poultry Fence Fabric (Hexagonal and Straight Line)C1186 Specification for Flat Fiber-Cement SheetsC1288 Specification for Fiber-Cement Interior Substrate SheetsD4442 Test Methods for Direct Moisture Content Measurement of Wood and Wood-Based Materials1 This test method is under the jur

14、isdiction of ASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommittee E05.22 on Surface Burning.Current edition approved Aug. 1, 2017Nov. 1, 2017. Published August 2017December 2017. Originally approved in 1950. Last previous edition approved in 20162017as E84 16.E84 17.

15、 DOI: 10.1520/E0084-17.10.1520/E0084-17A.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not

16、 an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate

17、. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D44

18、44 Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture MetersE69 Test Method for Combustible Properties of Treated Wood by the Fire-Tube ApparatusE160 Test Method for Combustible Properties of Treated Wood by the Crib Test 3E162 Test Method for Surface Flammability of Ma

19、terials Using a Radiant Heat Energy SourceE176 Terminology of Fire StandardsE286 Test Method for Surface Flammability of Building Materials Using an 8-ft (2.44-m) Tunnel Furnace (Withdrawn 1991)3E2231 Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surf

20、ace BurningCharacteristicsE2404 Practice for Specimen Preparation and Mounting of Textile, Paper or Polymeric (Including Vinyl) and Wood Wall orCeiling Coverings, Facings and Veneers, to Assess Surface Burning CharacteristicsE2573 Practice for Specimen Preparation and Mounting of Site-Fabricated Str

21、etch Systems to Assess Surface BurningCharacteristicsE2579 Practice for Specimen Preparation and Mounting of Wood Products to Assess Surface Burning CharacteristicsE2599 Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier and Vinyl Stretch CeilingMaterials for Bu

22、ilding Applications to Assess Surface Burning CharacteristicsE2688 Practice for Specimen Preparation and Mounting of Tapes to Assess Surface Burning CharacteristicsE2690 Practice for Specimen Preparation and Mounting of Caulks and Sealants to Assess Surface Burning CharacteristicsE2768 Test Method f

23、or Extended Duration Surface Burning Characteristics of Building Materials (30 min Tunnel Test)E2988 Practice for Specimen Preparation and Mounting of Flexible Fibrous Glass Insulation for Metal Buildings to AssessSurface Burning Characteristics2.2 NFPA Standards:4NFPA 262 Standard Method of Test fo

24、r Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces (2007)2.3 UL Standards5UL 1820 Standard for Safety for Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics (2004)UL 1887 Standard for Fire Test of Plastic Sprinkler Pipe for Visible Flame and Smoke Characterist

25、ics (2004)UL 2024 Standard for Safety for Optical Fiber and Communication Cable Raceway (2004)3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method refer to Terminology E176. The term flame spread index fromTerminology E176 is of particular interest to this standard a

26、nd is defined in 3.1.2.3.1.2 flame spread index, na number or classification indicating a comparative measure derived from observations madeduring the progress of the boundary of a zone of flame under defined test conditions.3.2 Definitions of Terms Specific to This Standard:3.2.1 smoke developed in

27、dex, na number or classification indicating a comparative measure derived from smoke obscurationdata collected during the test for surface burning characteristics.3.2.2 surface flame spread, nthe propagation of a flame away from the source of ignition across the surface of the specimen.4. Significan

28、ce and Use4.1 This test method is intended to provide only comparative measurements of surface flame spread and smoke densitymeasurements with that of select grade red oak and fiber-cement board surfaces under the specific fire exposure conditionsdescribed herein.4.2 This test method exposes a nomin

29、al 24-ft (7.32-m) long by 20-in. (508-mm) wide specimen to a controlled air flow andflaming fire exposure adjusted to spread the flame along the entire length of the select grade red oak specimen in 512 min.4.3 This test method does not provide for the following:4.3.1 Measurement of heat transmissio

30、n through the tested surface.4.3.2 The effect of aggravated flame spread behavior of an assembly resulting from the proximity of combustible walls andceilings.4.3.3 Classifying or defining a material as noncombustible, by means of a flame spread index by itself.5. Apparatus5.1 Fire Test ChamberSee F

31、igs. 1-5.5.1.1 The fire test chamber is a rectangular horizontal duct with a removable lid. The inside dimensions are as follows:3 The last approved version of this historical standard is referenced on www.astm.org.4 Available from National Fire Protection Association, 1 Battery March Park, Quincy,

32、MA 02169.5 Available from Underwriters Laboratories, 333 Pfingsten Road, Northbrook, IL 60062.E84 17a2Width: 17 34 14 in. (451 6.3 mm) measured between the topledges along the side walls, and 17 58 38 in. (448 10mm) at all other points.Depth: 12 12 in. (305 13 mm) measured from the bottom of thetest

33、 chamber to the top of the ledges on which thespecimen is supported. This measurement includes the 18in. (3.2 mm) thickness of the 1 12 in. (38 mm) wide wovenfiberglass gasket tape.Length: 25 ft 3 in. (7.62 m 76 mm).5.1.2 The sides and base of the chamber shall be lined with an insulating firebrick

34、with the dimensions of 4 12 in. by 9 in. by2 12 in. thick as illustrated in Fig. 2. The insulating firebrick shall have the following properties:Maximum Recommended Temperature 2600F (1427C)Bulk Density 48 3 lb/ft3 (0.77 0.046 g/cm3)Thermal Conductivity at MeanTemperature of Btuin./hft2F W/mC500F (2

35、60C) 1.6 0.231000F (538C) 1.9 0.271500F (815C) 2.2 0.322000F (1093C) 2.6 0.375.1.3 One side of the chamber shall be provided with double observation windows6 with the inside pane flush mounted (see Fig.2). Exposed inside glass shall be 2 34 6 38 by 11 + 1, 2 in. (70 6 10 by 279 + 25 50 mm). The cent

36、erline of the exposed areaof the inside glass shall be in the upper half of the furnace wall, with the upper edge not less than 2.5 in. (63 mm) below the furnaceledge. The window shall be located such that not less than 12 in. (305 mm) of the specimen width can be observed. Multiplewindows shall be

37、located along the tunnel so that the entire length of the test sample is observable from outside the fire chamber.The windows shall be pressure tight in accordance with 7.2 and 7.2.1.5.1.4 The ledges shall be fabricated of structural materials7 capable of withstanding the abuse of continuous testing

38、. The ledgesshall be level with respect to the length and width of the chamber and each other. The ledges shall be maintained in a state of repaircommensurate with the frequency, volume, and severity of testing occurring at any time.5.1.5 Lid:6 Heat-resistant glass, high-silica, 100 % silica glass,

39、nominal 14-in. thick has been found suitable for the interior pane. Borosilicate glass, nominal 14-in. thick has beenfound suitable for the exterior pane.7 High-temperature furnace refractory. Zirconium silicate, or water-cooled steel tubing have been found suitable for this purpose.FIG. 1 Test Furn

40、ace, Showing Some Critical Dimensions (Not a Construction Drawing)E84 17a35.1.5.1 The lid shall consist of a removable noncombustible metal and mineral composite structure as shown in Fig. 2 and ofa size necessary to cover completely the fire test chamber and the test samples. The lid shall be maint

41、ained in an unwarped andflat condition. When in place, the lid shall be completely sealed to prevent air leakage into the fire test chamber during the test.5.1.5.2 The lid shall be insulated with a minimal thickness of 2 in. (51 mm) castable insulation or mineral composite materialhaving physical ch

42、aracteristics comparable to the following:Maximum effective use temperature ofat least: 1200F (650C)Bulk density 21 lb/ft3 (336 kgm3)Bulk density 21 lb/ft3 (336 kg/m3)Thermal conductivity at 300 to 700F(149 to 371C)0.50 to 0.71 Btuin./hft2F (0.072 to0.102 W/mK)5.1.5.3 The entire lid assembly shall b

43、e protected with flat sections of nominal 14-in. (6.3-mm) fiber-cement board meeting theproperties of Annex A3. This protective board shall be maintained in sound condition through continued replacement. Theprotective board is to be secured to the furnace lid or place on the back side of the test sp

44、ecimen.5.1.6 Gas Burners:FIG. 2 Test Furnace Showing Critical Dimensions (Not a Construction Drawing)E84 17a45.1.6.1 One end of the test chamber shall be designated as the “fire end”. This fire end shall be provided with two gas burnersdelivering flames upward against the surface of the test sample

45、(see Fig. 2). The burners shall be spaced 12 in. (305 mm) fromthe fire end of the test chamber, and 7 12 6 12 in. (190 6 13 mm) below the under surface of the test sample. Gas to the burnersshall be provided through a single inlet pipe, distributed to each port burner through a tee-section. The outl

46、et shall be a 34 in. NPTelbow. The plane of the port shall be parallel to the furnace floor, such that the gas is directed upward toward the specimen. Eachport shall be positioned with its centerline 4 6 12 in. (102 6 13 mm) on each side of the centerline of the furnace so that the flameis distribut

47、ed evenly over the width of the exposed specimen surface (see Fig. 2).5.1.6.2 The controls used to assure constant flow of gas to the burners during period of use shall consist of a pressure regulator,a gas meter constructed to read in increments of not more than 0.1 ft3 (2.8 L), a manometer to indi

48、cate gas pressure in inches ofwater, a quick-acting gas shut-off valve, and a gas metering valve.5.1.7 Air Intake:5.1.7.1 An air intake shutter shall be located 54 6 5 in. (1372 6 127 mm) upstream of the burner, as measured from the burnercenterline to the outside surface of the shutter (see Fig. 1)

49、. The air intake is to be fitted with a vertically sliding shutter extendingthe entire width of the test chamber. The shutter shall be positioned so as to provide an air inlet port 3 6 116 in. (76 6 2 mm) highmeasured from the floor level of the test chamber at the air intake point.5.1.7.2 To provide air turbulance for proper combustion, turbulance baffling shall be provided by positioning six refractoryfirebricks (as defined in 5.1.2) along the side walls of the chamber. With the long dimension vertic