1、BRITISH STANDARD AEROSPACE SERIES BS EN 3841-301:2004 Circuit breakers Test methods Part 301: Voltage drop The European Standard EN 3841-301:2004 has the status of a British Standard ICS 49.060 BS EN 3841-301:2004 This British Standard was published under the authority of the Standards Policy and St
2、rategy Committee on 22 February 2005 BSI 22 February 2005 ISBN 0 580 45524 6 National foreword This British Standard is the official English language version of EN 3841-301:2004. The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibr
3、e optic technology, to Subcommittee ACE/6/5, Circuit breakers, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred
4、 to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provision
5、s of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or
6、proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 5 and a back cover. The BSI copyright notice d
7、isplayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN3841301 December2004 ICS49.060 Englishversion AerospaceseriesCircuitbreakersTestmethodsPart301: Voltagedrop Sriearospatial
8、eDisjoncteursMthodesdessais Partie301:Chutedetension LuftundRaumfahrtSchutzschalterPrfverfahrenTeil 301:Spannungsabfall ThisEuropeanStandardwasapprovedbyCENon10September2004. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthes
9、tatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslat
10、ion undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuan
11、ia,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandb
12、yanymeansreserved worldwideforCENnationalMembers. Ref.No.EN3841301:2004:EEN 3841-301:2004 (E) 2 Contents Page 1 Scope 4 2 Normative references 4 3 Method 4 EN 3841-301:2004 (E) 3 Foreword This document (EN 3841-301:2004) has been prepared by the European Association of Aerospace Manufacturers - Stan
13、dardization (AECMA-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of AECMA, prior to its presentation to CEN. This European Standard
14、shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2005, and conflicting national standards shall be withdrawn at the latest by June 2005. According to the CEN/CENELEC Internal Regulations, the national standards orga
15、nizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, S
16、lovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 3841-301:2004 (E) 4 1 Scope This standard specifies a method of verifying the voltage drop of circuit breakers. It shall be used together with EN 3841-100. 2 Normative references The following referenced documents are indispensable for t
17、he application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3841-100, Aerospace series Circuit breakers Test methods Part 100: General 3 Method 3.1 Main contacts at
18、 rated current test 3.1.1 Procedure This measurement shall be carried out after the circuit breaker has carried its rated current for a minimum period of 30 min in order to achieve thermal stabilization. The voltage drop shall be measured between the input and output terminal of each pole. Six measu
19、rements, each interrupted by one manual break operation and one manual make operation, shall be carried out at each circuit breaker pole. 3.1.2 Requirement The mean value of the six individual measurements shall not exceed the value specified in the product standard. 3.2 Main contacts at low current
20、 test 3.2.1 Procedure Measurement of the voltage drop at low current shall be carried out on circuit breakers which have not been subjected to any previous electrical test. The circuit breakers shall be loaded with the low current (d.c. only) specified in the product standard. Measurements shall be
21、carried out following a 1 min stabilization period. The voltage drop shall be measured between the input and output terminal of each pole. Six measurements shall be carried out at each circuit breaker pole. Each measurement shall be interrupted by one manual break operation and one manual make opera
22、tion. With d.c. measurements the current direction shall be inverted after three measurements. 3.2.2 Requirement The mean value of the six individual measurements shall not exceed the value indicated in the product standard. EN 3841-301:2004 (E) 5 3.3 Signal contacts 3.3.1 Procedure The signal conta
23、cts shall be loaded with the currents and voltages indicated in the technical specification. After stabilization, the voltage drop shall be measured between input and output terminals. Six measurements shall be taken with each contact. With d.c. measurements, the current direction shall be inverted
24、after three measurements (when the signal contact is not polarized). Each measurement shall be interrupted by one manual break operation and one manual make operation. 3.3.2 Requirement The mean value of the six individual measurements shall not exceed the value indicated in the product standard. BS
25、 EN 3841-301:2004 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions
26、 British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambigui
27、ty while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which ensures that s
28、ubscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from
29、the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, E
30、uropean and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048.
31、 Email: infobsi-. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: mem
32、bershipbsi-. Information regarding online access to British Standards via British Standards Online can be found at http:/www.bsi- Further information about BSI is available on the BSI website at http:/www.bsi-. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in th
33、e UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without
34、prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: copyrightbsi-.