BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf

上传人:Iclinic170 文档编号:573047 上传时间:2018-12-13 格式:PDF 页数:20 大小:694.07KB
下载 相关 举报
BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf_第1页
第1页 / 共20页
BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf_第2页
第2页 / 共20页
BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf_第3页
第3页 / 共20页
BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf_第4页
第4页 / 共20页
BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、BS EN15267-1:2009ICS 13.040.99NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAir quality Certification ofautomated measuringsystemsPart 1: General principlesThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 30

2、 April2009 BSI 2009ISBN 978 0 580 57914 1Amendments/corrigenda issued since publicationDate CommentsBS EN 15267-1:2009National forewordThis British Standard is the UK implementation of EN 15267-1:2009.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/1, Stationary sour

3、ce emission.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immu

4、nityfrom legal obligations.BS EN 15267-1:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15267-1March 2009ICS 13.040.99English VersionAir quality - Certification of automated measuring systems - Part1: General principlesQualit de lair - Certification des systmes de mesurageautomatiss - Partie

5、1 : Principes gnrauxLuftbeschaffenheit - Zertifizierung von automatischenMesseinrichtungen - Teil 1: GrundlagenThis European Standard was approved by CEN on 14 February 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europ

6、eanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English,

7、French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus

8、, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EU

9、ROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15267-1:2009: EBS EN 15267-1:2009EN 15267-1:2009 (E) 2 Contents Page Forewo

10、rd 3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Abbreviations .7 5 Principles 7 5.1 Performance testing of the automated measuring system .7 5.2 Initial assessment of the AMS manufacturers quality management system .8 5.3 Certification 8 5.4 Surveillance 8 6 Role

11、s and responsibilities 9 6.1 General 9 6.2 Roles and responsibilities of the manufacturer .9 6.3 Roles and responsibilities of the test laboratory .9 6.4 Roles and responsibilities of the relevant body 10 7 Certification procedure 11 7.1 General . 11 7.2 Performance testing of the automated measurin

12、g system 11 7.3 Initial assessment of the manufacturers quality management system . 11 7.4 Certification . 11 7.5 Surveillance . 12 7.6 Review of certifications 13 Annex A (informative) Application and assessment processes 14 Annex B (informative) Example certificate template . 15 Bibliography . 17

13、BS EN 15267-1:2009EN 15267-1:2009 (E) 3 Foreword This document (EN 15267-1:2009) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical

14、text or by endorsement, at the latest by September 2009, and conflicting national standards shall be withdrawn at the latest by September 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held r

15、esponsible for identifying any or all such patent rights. This document is Part 1 of a series of European Standards: EN 15267-1, Air quality Certification of automated measuring systems Part 1: General principles EN 15267-2, Air quality Certification of automated measuring systems Part 2: Initial as

16、sessment of the AMS manufacturers quality management system and post certification surveillance for the manufacturing process EN 15267-3, Air quality Certification of automated measuring systems Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions

17、 from stationary sources According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,

18、Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15267-1:2009EN 15267-1:2009 (E) 4 Introduction The certification of automated measuring systems (AMS) supports t

19、he requirements of certain Directives of the European Union (EU), which require, either directly or indirectly, that AMS comply with performance criteria, maximum permissible measurement uncertainties and testing requirements. These Directives include the Directive on the limitation of emissions of

20、certain pollutants into the air from large combustion plants 1, the Directive on the incineration of waste 2 and the Framework Directive on ambient air quality assessment and management 3 and the associated daughter directives 4, 5, 6 and 7. The responsibility for approving AMS for monitoring ambien

21、t air quality under Directive 96/62/EC lies with the national competent authority or a body designated by the EU member state. No explicit requirement for approving AMS for monitoring emissions from stationary sources is defined in the relevant EU Directives, although the competent authorities in so

22、me EU member states have such arrangements in place. In some EU member states the competent authority delegates the responsibility for approval of AMS to a certification body accredited to EN 45011 by national accreditation bodies. In some EU member states the competent authority cannot be accredite

23、d by external bodies, in others they may be. These approaches have built up over many years and reflect the different administrative and legal arrangements that exist in the EU member states. In order to recognize these different approaches, this European Standard uses the collective term “relevant

24、body” when referring to competent authority or certification body. The terms “competent authority” and “certification body” are only used where it is necessary to be specific for the purpose of clarity in the way in which a requirement applies under the different approaches. The European Standard EN

25、 45011 specifies general criteria that a certification body operating product certification shall follow if it is to be recognized at a national or European level as competent and reliable in the operation of a product certification system, irrespective of the sector involved. It is intended for the

26、 use of accreditation bodies concerned with recognizing the competence of certification bodies. EN 45011 is identical to ISO/IEC Guide 65. The document EA-6/01 8 published by the International Accreditation Forum (IAF) provides guidelines on the application of EN 45011. The purpose of EA-6/01 is to

27、harmonise the worldwide application of EN 45011 by accreditation bodies as an important step towards mutual recognition between certification bodies under the IAF Multilateral Agreement (MLA). EN 45011 recognizes that these general criteria may have to be supplemented when applied to a particular se

28、ctor. This European Standard provides guidance on the application of EN 45011 to the certification of AMS for monitoring ambient air quality and emissions from stationary sources. It is Part 1 of a three part series of European Standards, which specify common requirements for the certification of AM

29、S in EU member states. This European Standard defines common procedures and requirements for the certification of AMS to facilitate mutual recognition by the relevant bodies and thereby minimise administrative and cost burdens on AMS manufacturers seeking certification in multiple member states. It

30、also describes the roles and responsibilities of manufacturers, test laboratories, certification bodies (for quality management systems) and relevant bodies under these procedures. BS EN 15267-1:2009EN 15267-1:2009 (E) 5 1 Scope This European Standard specifies the general principles, including comm

31、on procedures and requirements, for the product certification of automated measuring systems (AMS) for monitoring ambient air quality and emissions from stationary sources. This product certification consists of the following sequential stages: a) performance testing of an automated measuring system

32、; b) initial assessment of the AMS manufacturers quality management system; c) certification; d) surveillance. This European Standard applies to the certification of all AMS for monitoring ambient air quality and emissions from stationary sources for which performance criteria and test procedures ar

33、e available in European Standards. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)

34、applies. EN 14211, Ambient air quality Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence EN 14212, Ambient air quality Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence EN 1462

35、5, Ambient air quality Standard method for the measurement of the concentration of ozone by ultraviolet photometry EN 14626, Ambient air quality Standard method for the measurement of the concentration of carbon monoxide by nondispersive infrared spectroscopy EN 14662-3, Ambient air quality Standard

36、 method for measurement of benzene concentrations Part 3: Automated pumped sampling with in situ gas chromatography EN 15267-2, Air quality Certification of automated measuring systems Part 2: Initial assessment of the AMS manufacturers quality management system and post certification surveillance f

37、or the manufacturing process EN 15267-3, Air quality Certification of automated measuring systems Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources EN 45011, General requirements for bodies operating product certificatio

38、n systems (ISO/IEC Guide 65:1996) EN ISO 9001, Quality management systems Requirements (ISO 9001:2000) EN ISO/IEC 17021, Conformity assessment Requirements for bodies providing audit and certification of management systems (ISO/IEC 17021:2006) EN ISO/IEC 17025, General requirements for the competenc

39、e of testing and calibration laboratories (ISO/IEC 17025:2005) BS EN 15267-1:2009EN 15267-1:2009 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 automated measuring system AMS entirety of all measuring instruments and additional devices

40、 for obtaining a result of measurement NOTE 1 Apart from the actual measuring device (the analyser), an AMS includes facilities for taking samples (e.g. probe, sample gas lines, flow meters and regulator, delivery pump) and for sample conditioning (e.g. dust filter, pre-separator for interferents, c

41、ooler, converter). This definition also includes testing and adjusting devices that are required for functional checks and, if applicable, for commissioning. NOTE 2 The term “automated measuring system” (AMS) is typically used in Europe. The terms “continuous emission monitoring system” (CEM) and “c

42、ontinuous ambient-air-quality monitoring system” (CAM) are also typically used in the UK and USA. 3.2 relevant body competent authority or certification body, nominated by a competent authority or EU member state, that carries out the certification of automated measuring systems 3.3 competent author

43、ity organisation which implements the requirements of EU Directives and regulates installations, which must comply with the requirements of applicable European Standards 3.4 certification body any body operating a product certification system or any body accredited to EN ISO/IEC 17021 for the certif

44、ication of quality management systems 3.5 manufacturer organisation, situated at a stated location or locations, that carries out or controls such stages in the manufacture, assessment, handling and storage of a product that enables it to accept responsibility for continued compliance of the product

45、 and its certification, and undertakes all obligations in that connection NOTE The term “manufacturer“ is used instead of “organisation“ as used in EN ISO 9001. For the purpose of this document they are interchangeable. 3.6 test laboratory laboratory accredited to EN ISO/IEC 17025 for carrying out t

46、he performance tests on automated measuring systems in accordance with applicable European Standards 3.7 product automated measuring system 3.8 technical file record of the reference documents and design changes to the reference documents 3.9 reference document document that controls the manufacture

47、 and design of an AMS and is referenced in the test report BS EN 15267-1:2009EN 15267-1:2009 (E) 7 NOTE Reference documents can include drawings, specifications, instructions and computer code. 3.10 related document document not referenced in the test report NOTE A related document can be used, for

48、example, for the detailed manufacture of component parts. 3.11 certification range range over which the automated measuring system is tested and certified for compliance with the relevant performance criteria NOTE 1 The lower limit is typically the detection limit of the AMS and often considered to

49、be zero. NOTE 2 Generally, the lower the certification range, the better the performance of the AMS. Also an AMS typically performs satisfactorily at higher values over the measurement range. 3.12 surveillance systematic iteration of conformity assessment activities as a basis for maintaining the validity of the statement of conformity EN ISO/IEC 17000:2004, 6.1 NOTE For the purposes of this European Standard surveillance focuses on the manufacturers quality management system to ensure that automated measuring systems