BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf

上传人:jobexamine331 文档编号:573311 上传时间:2018-12-13 格式:PDF 页数:58 大小:946.54KB
下载 相关 举报
BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf_第1页
第1页 / 共58页
BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf_第2页
第2页 / 共58页
BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf_第3页
第3页 / 共58页
BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf_第4页
第4页 / 共58页
BS EN 15611-2008 Railway applications - Braking - Relay valves《轨道交通 制动 中继阀》.pdf_第5页
第5页 / 共58页
点击查看更多>>
资源描述

1、BS EN 15611:2008ICS 45.060.01NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDRailway applications Braking RelayvalvesLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIThis British Standardwas published under theau

2、thority of the StandardsPolicy and StrategyCommittee on 31 December2008 BSI 2008ISBN 978 0 580 58006 2Amendments/corrigenda issued since publicationDate CommentsBS EN 15611:2008National forewordThis British Standard is the UK implementation of EN 15611:2008.The UK participation in its preparation wa

3、s entrusted to TechnicalCommittee RAE/4, Braking.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with

4、a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15611November 2008ICS 45.060.01English VersionRailway applications - Br

5、aking - Relay valvesApplications ferroviaires - Freinage - Relais pneumatiques Bahnanwendungen - Bremse - RelaisventileThis European Standard was approved by CEN on 27 September 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving t

6、his EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (

7、English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgari

8、a, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIO

9、NCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15611:2008: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDAR

10、DS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 2 Contents Page Foreword4 1 Scope 5 2 Normative references 5 3 Terms and definitions, symbols and abbreviations.5 3.1 Terms and definitions .5 3.2 Symbols 9 3.3 Abbreviations.10 4 Design and manufacture.10 4.1 General1

11、0 4.2 Functional requirements.12 4.2.1 Minimum output pressure.12 4.2.2 Accuracy of the output pressure and changeover.13 4.2.3 Load signal characteristics 13 4.2.4 Enabling of a change of relay valve ratio during brake application of a relay valve of type B1 14 4.2.5 Prevention of a change of relay

12、 valve ratio during brake application of a relay valve of type B2 and a variable load relay valve, types C, C1, D, E 14 4.2.6 Kinked characteristic of a variable load relay valve (type E) 14 4.2.7 Interaction of a relay valve and a distributor valve15 4.2.8 Hysteresis.16 4.2.9 Sensitivity.16 4.2.10

13、Flow.16 4.2.11 Leakage.16 4.2.12 Change of relay valve ratio.16 4.3 Shock and vibration 17 4.4 Environment requirements .17 4.4.1 General17 4.4.2 Temperature .17 4.4.3 Other environmental conditions 18 4.5 Compressed air quality .19 4.6 Service life 20 4.7 Fire behaviour 20 4.8 External appearance20

14、 4.9 Design requirements regarding pressure stress .20 4.10 Interface 20 4.10.1 General20 4.10.2 Mechanical20 4.10.3 Pneumatic.20 5 Materials .21 6 Type tests .21 6.1 General21 6.2 Individual relay valve tests .21 6.2.1 Test bench for individual relay valves.21 6.2.2 Sampling for type tests .24 6.2.

15、3 Test temperature and air quality 24 6.2.4 Procedure for type tests .24 7 Routine test and inspection47 8 Type-validation.47 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 3 9 Documentation 47 10 Designation 48 11

16、 Identification and marking48 Annex A (informative) In-service trial .49 A.1 General .49 A.2 Test set-up and sampling .49 A.3 Procedure.49 A.4 Pass/fail criteria .49 Annex B (informative) Static vehicle and running tests .50 B.1 General .50 B.2 Test recommendations .50 B.2.1 Variable load relay valv

17、e.50 B.2.2 Empty/load relay valve51 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 96/48/EC as modified by Directive 2004/50/EC.52 Annex ZB (informative) Relationship between this European Standard and the Essential Requirements of E

18、U Directive 2001/16/EC of the European Parliament and of the Council of 19 March 2001 on the interoperability of the trans-European conventional rail system, as modified by EU Directive 2004/50/EC of 29 April 2004 .53 Bibliography54 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 0

19、1:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 4 Foreword This document (EN 15611:2008) has been prepared by Technical Committee CEN/TC 256 “Railway applications”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, eit

20、her by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENE

21、LEC shall not be held responsible for identifying any or all such patent rights. This European Standard has been prepared under a mandate given to CEN/CENELEC/ETSI by the European Commission and the European Free Trade Association and supports essential requirements of EU Directive 96/48 and EU Dire

22、ctive 2001/16, as modified by EU Directive 2004/50. For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to imp

23、lement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerlan

24、d and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 5 1 Scope This European Standard is applicable to relay valves designed to control the brake cylinder pressure of compressed air brakes fitte

25、d to railway vehicles, in association with an air brake distributor valve or other control device, and in response to a change in vehicle load that is either continuously variable or in two stages i.e. empty - loaded. Relay valves operating with other pressures, in particular the brake pipe pressure

26、, are not included. This European Standard specifies the requirements for the design, manufacture and testing of relay valves. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For u

27、ndated references, the latest edition of the referenced document (including any amendments) applies. EN 14478:2005, Railway applications Braking Generic vocabulary EN 15355, Railway applications Braking - Distributor valves and distributor-isolating devices EN 15625, Railway applications Braking Aut

28、omatic variable load sensing devices EN 50125-1, Railway applications Environmental conditions for equipment Part 1: Equipment on board rolling stock EN 60721-3-5:1997, Classification of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Sectio

29、n 5: Ground vehicle installations (IEC 60721-3-5:1997) EN 61373:1999, Railway applications Rolling stock equipment Shock and vibration tests (IEC 61373:1999) EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation (ISO 228-1:2

30、000) ISO 8573-1:2001, Compressed air Part 1: Contaminants and purity classes 3 Terms and definitions, symbols and abbreviations For the purposes of this document, the terms and definitions, symbols and abbreviations given in EN 14478:2005 and the following apply. 3.1 Terms and definitions 3.1.1 rela

31、y valve device, the main function of which is to control a pneumatic output pressure as a function of the variation of one or more input pressures NOTE 1 See Figure 1. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E)

32、 6 Key 1 first input pressure 2 second input pressure 3 control signal - continuous load sensing pressure (Lcp), or control signal - empty/load signal pressure (Lsp), or mechanical input (lever) or electrical input 4 auxiliary reservoir pressure, supply pressure (AR) 5 output pressure 6 relay valve

33、Figure 1 Relay valve, pressures and control signals NOTE 2 The definition of “relay valve” in EN 14478 is specific to a load dependant relay valve. This EN standard considers one or more input pressures in accordance with the diagram in Figure 1. 3.1.2 input pressure control pressure received by the

34、 relay valve NOTE Pressure generally considered as being the output pressure from a distributor or a brake control unit; sometimes referred to as pilot pressure or dummy brake cylinder pressure. 3.1.3 output pressure pressure output from the relay valve NOTE Pressure generally considered as being th

35、e brake cylinder pressure when the relay valve is used in a variable load braking system. This pressure can also be used as the input pressure to another relay valve. The output pressure can obtain one, two or three fixed levels or it can be changed continuously between a minimum and a maximum or vi

36、ce versa. 3.1.4 relay valve ratio ratio of the output pressure to input pressure Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 7 3.1.5 control signal signal received from the continuous load sensing device (Lcp) o

37、r empty - loaded changeover device (Lsp) or a mechanical input (lever) or an electrical input that varies the relay valve ratio dependant on vehicle load NOTE This can also be a speed signal or other parameter, dependant on the relay valve application. 3.1.6 Relay valve types 3.1.6.1 single stage re

38、lay valve relay valve type A relay valve with one fixed relay valve ratio, where the ratio can be less (step-down), equal or greater (step-up) than 1 3.1.6.2 multi stage relay valve relay valve type B relay valve with more than one fixed relay valve ratio, where the ratios can be less (step-down), e

39、qual or greater (step-up) than 1 3.1.6.2.1 relay valve type B1 multi stage relay valve that can change relay valve ratio during a brake application NOTE Typically used on vehicles normally operated in empty or fully loaded condition. 3.1.6.2.2 relay valve type B2 multi stage relay valve where a chan

40、ge of relay valve ratio cannot take place during a brake application NOTE Blocking the relay valve ratio during brake application is typically used to avoid frequent changeovers taking place on vehicles operated near the changeover weight. 3.1.6.2.3 empty/load relay valve specific type of multi stag

41、e relay valve (type B1 or B2) with only two stages, giving an empty (tare) or a loaded output pressure proportional to input pressure dependant on the load signal input 3.1.6.3 variable load relay valve relay valve type C relay valve with a continuously changeable relay valve ratio, where a load sig

42、nal is used to change the ratio 3.1.6.4 multi stage variable load relay valve relay valve type C1 relay valve with a continuously changeable relay valve ratio, where a load signal is used to change the ratio and with a multi stage feature added NOTE Typically a load signal is used to change the rela

43、y valve ratio and a control signal (automatic or manual) is used to change the stage(s). The typical result is that at the same load and input pressure, in the lower stage (e.g. P-mode, passenger train) results a lower output pressure and in a higher stage (e.g. R-mode, rapid passenger train) this r

44、esults in a higher output pressure. 3.1.6.5 two (multi) input relay valve relay valve type D relay valve (type A, B or C) with two (or more) input pressures, controlling a single output pressure Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN

45、15611:2008EN 15611:2008 (E) 8 3.1.6.6 variable load relay valve with kinked characteristic relay valve type E variable load relay valve (Type C) with a special, non-linear characteristic, which automatically comes into operation when the vehicle has more than a certain load NOTE This function reduce

46、s (in comparison with a linear characteristic) the output pressure for low input pressures to a certain level to limit the heat impact to the wheels during continuous braking. 3.1.7 sensitivity change of input pressure causing a variation of output pressure, when the change of input pressure is in t

47、he same direction, with no overshoot or reversal 3.1.8 initial sensitivity change of input pressure, starting at 0 bar which causes the output pressure to start increasing NOTE See Figure 2. 3.1.9 sensitivity at reversal change of input pressure causing a variation of output pressure, when the chang

48、e of input pressure is changing its direction from increasing to decreasing NOTE See Figure 2. 3.1.10 hysteresis difference in output pressure with the same input pressure, where the input pressure is first rising to a value and then, having been taken past that value, subsequently falls to the same

49、 value NOTE See Figure 2. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/05/2009 01:46, Uncontrolled Copy, (c) BSIBS EN 15611:2008EN 15611:2008 (E) 9 Key 1 initial sensitivity 2 hysteresis 3 sensitivity at reversal NOTE The figure is simplified for illustrative purposes, e.g. the real pressure development is not shown. Figure 2 Hysteresis and sensitivity 3.1.11 initial braking position first braking step corresponding to a reduction of the brake pipe pressure of 0,4 bar to 0,5 bar, which results in an input pressure to the relay valve of (