BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf

上传人:sumcourage256 文档编号:573658 上传时间:2018-12-13 格式:PDF 页数:32 大小:1.25MB
下载 相关 举报
BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf_第1页
第1页 / 共32页
BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf_第2页
第2页 / 共32页
BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf_第3页
第3页 / 共32页
BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf_第4页
第4页 / 共32页
BS EN 16145-2012 Sanitary tapware Extractable outlets for sink and basin mixers General technical specification《卫生设备配件 水槽和脸盆龙头用可引出排水口 通用技术规范》.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 16145:2012Sanitary tapware Extractable outlets for sinkand basin mixers Generaltechnical specificationCopyright European Committee for Standardization Provided by IHS under

2、 license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16145:2012.The UK participation in its preparation was entrusted to TechnicalCommittee B/504/-/8,

3、 Sanitary tapware.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Publish

4、ed by BSI StandardsLimited 2013ISBN 978 0 580 71792 5ICS 91.140.70Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2013.Amendments issued since publicati

5、onDate Text affectedCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16145 December 2012 ICS 91.140.70 English

6、 Version Sanitary tapware - Extractable outlets for sink and basin mixers -General technical specification Robinetterie sanitaire - Douchettes extractibles pour mitigeurs dviers et de lavabos - Spcifications techniques gnrales Sanitrarmaturen - Ausziehbare Auslufe fr Waschtisch- und Splbeckenarmatur

7、en - Allgemeine technische Spezifikation This European Standard was approved by CEN on 10 November 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

8、. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t

9、ranslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fi

10、nland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZA

11、TION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16145:2012: ECopyright European Committee for Standardizat

12、ion Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 93 Terms and definitions .94 Classification 95 Designation . 106 Mar

13、king 107 Materials 107.1 Chemical and hygienic requirements . 107.2 Exposed surface condition and quality of coating . 108 Dimensional Characteristics . 108.1 General . 108.2 Connecting Dimensions . 108.3 Special Cases 119 Leaktightness Characteristics . 119.1 Leaktightness of the inlet connection a

14、nd the spray plate 119.2 Leaktightness of manually operated spray mode selector 139.3 Leaktightness and operation of spray mode selectors with automatic return 1310 Mechanical Characteristics . 1410.1 General . 1410.2 Mechanical Strength . 1410.3 Mechanical endurance of spray mode selectors . 1510.4

15、 Thermal Shock Test 1711 Hydraulic Characteristics 1811.1 General . 1811.2 Flow rate Test method . 1812 Backflow protection 2012.1 General . 2012.2 Standard connection 2112.3 Special connection . 2213 Acoustic characteristics 2313.1 General . 2313.2 Procedure 2313.3 Expression of results . 2313.4 De

16、termination of acoustic group 2314 Rotary connection 2314.1 General . 2314.2 Test method . 23Annex A (informative) Pressure take-off tee 25Bibliography . 28Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted wit

17、hout license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 3 Foreword This document (EN 16145:2012) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publi

18、cation of an identical text or by endorsement, at the latest by June 2013, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall

19、not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmar

20、k, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Copyright Europe

21、an Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 4 Introduction In respect of potential adverse effects on the quality of water intended for human consumption, c

22、aused by the product covered by this standard: This standard provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA. It should be noted that, while awaiting the adoption of verifiable European criteria, existing national regula

23、tions concerning the use and/or the characteristics of these products remain in force. This European Standard specifies requirements for shower outlets suitable for use in water supply systems of Type 1 and Type 2. Copyright European Committee for Standardization Provided by IHS under license with C

24、ENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 5 1 Scope This European Standard specifies: the dimensional, leaktightness, mechanical, hydraulic and acoustic characteristics with which extractable outlets with or without spray m

25、ode selector function need to comply; the procedures for testing these characteristics. It applies to extractable outlets made from any material which is intended for equipping and supplementing sanitary tapware for sinks and wash-basins used for culinary or ablutionary purposes. Such extractable ou

26、tlets shall only be connected downstream of the obturator of the tapware. Extractable outlets with total closing device fitted after the obturator of the tapware are not covered by this standard. Such products will be tested in accordance with EN 200, EN 817, EN 1111, EN 1286 or EN 1287 (see 1, 2, 3

27、, 5 and 6). The conditions of use and classification are specified in Table 1. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 6 Table 1 Conditi

28、ons of use/Classifications Water Supply system Operating range of extractable shower outlets Flow rate classes Acoustics Marking Limits Recommended See Clause 13 See Clause 4 Type 1 see Figure 1Dynamic Pressure (0,05 to 0,5) MPa (0,5 to 5,0) bar) Dynamic Pressure (0,1 to 0,3) MPa (1,0 to 3,0) bar) Z

29、E (0,066 7 Q (0,01 to 0,2) MPa (0,1 to 2,0) bar) Dynamic Pressure (0,02 to 0,1) MPa(0,2 to 1,0) bar) EE (0,025 Q 0,06) l/s (1,5 Q 3,6) l/min) at 0,01 MPa (0,1 bar) (unclassified)E (0,06 Q 0,14) l/s (3,6 Q 8,4) l/min) at 0,01 MPa (0,1 bar) H (Q 0,14) l/s (Q 8,4) l/min) at 0,01 MPa (0,1 bar) Temperatu

30、re T 70 C T 42 C (wash-basin) T 60 C (sink) For low pressure extractable outlets complying with this standard there are no acoustical requirements. Low pressure extractable outlets complying with this standard may also be used with inlet supply pressures in the range from 0,1 MPa to 0,2 MPa (1,0 bar

31、 to 2,0 bar) on condition that acoustical performance is not a requirement of the installation. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E)

32、7 Key 1 cold water 2 hot Water 3 mains supply pipe (supply pressures up to 1 MPa (10 bar) 4 water heater Figure 1 Supply system type 1 with a pressure range of 0,05 MPa to 1,0 MPa (0,5 bar to 10 bar) Copyright European Committee for Standardization Provided by IHS under license with CENNot for Resal

33、eNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 8 Key 1 cold water storage cistern (cover omitted for clarity) 2 warning pipe 3 vent pipe 4 hot water cylinder 5 alternative cistern fed cold supply to sanitary appliances 6 to boiler 7 mains supp

34、ly pipe (supply pressures up to 1 MPa (10 bar) Figure 2 Supply system type 2 with a pressure range of 0,01 MPa to 1,0 MPa (0,1 bar - 10 bar). A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanita

35、ry appliances Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 9 2 Normative references The following documents, in whole or in part, are normati

36、vely referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 248, Sanitary tapware General specification for electrodeposi

37、ted coatings of Ni-Cr EN 1717, Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow EN 16146, Sanitary tapware Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2 General technical spe

38、cification EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation (ISO 228-1) EN ISO 3822-1, Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of meas

39、urement (ISO 3822-1) EN ISO 3822-4, Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4: Mounting and operating conditions for special appliances (ISO 3822-4) 3 Terms and definitions For the purposes of this document, the following ter

40、ms and definitions apply. 3.1 spray outlet device for culinary and ablutionary purposes which allows water to be emitted in the form of jets or water droplets 3.2 spray plate device with orifices through which water passes and forms a spray of water with separate, definable jets or water droplets No

41、te 1 to entry: A spray forming mechanism is a device which generates a spray by other means. 3.3 spray mode selector device providing the possibility of selecting different spray modes Note 1 to entry: Later described as mode (a), (b), (c). 4 Classification Extractable outlets are moveable hand held

42、 outlets which are connected to the sanitary tapware via a hose, complying with EN 16146. They can be mounted directly on the tapware or designed as a side spray located on an appropriate support. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo

43、 reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 10 5 Designation Extractable outlets covered by this standard are designated by: their connecting thread dimension; their flow rate class (see Table 1); their acoustic group (where applicable); refer

44、ence to this standard: EN 16145. EXAMPLE Extractable outlet G flow rate class E, EN 16145. 6 Marking Extractable outlets complying with this standard shall be marked permanently and legibly with the manufacturers mark or the suppliers mark. The acoustic group (where applicable) and the highest flow

45、rate class shall appear on the product but it need not be permanent. Extractable outlets with special connection (see 12.3) delivered together with the tapware need not be marked individually. 7 Materials 7.1 Chemical and hygienic requirements All materials coming into contact with water intended fo

46、r human consumption shall present no risk to health. They shall not cause any change of the drinking water in terms of quality, appearance, smell or taste. 7.2 Exposed surface condition and quality of coating Visible chromium plated surfaces and Ni-Cr coatings shall comply with the requirements of E

47、N 248. 8 Dimensional Characteristics 8.1 General The design and construction of components without defined dimensions permits various design solutions to be adopted by the manufacturer. Permitted deviations from the defined dimensions are given in 8.3. 8.2 Connecting Dimensions The connecting dimensions of extractable outlets are specified in Table 2. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 16145:2012EN 16145:2012 (E) 11 Figure 3 Extractable outlet