1、BSI Standards PublicationHousehold electric blankets Methods for measuring performanceBS EN 60299:2014National forewordThis British Standard is the UK implementation of EN 60299:2014. It is identical to IEC 60299:2014. It supersedes BS EN 60299:1994 which is withdrawn.The UK participation in its pre
2、paration was entrusted to TechnicalCommittee CPL/59, Performance of household electrical appliances.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are respo
3、nsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 83327 4ICS 97.100.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards
4、 Policy and Strategy Committee on 31 October 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60299:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 60299 September 2014 ICS 97.100.10 Supersedes EN 60299:1994 English Version Household electric blankets
5、- Methods for measuring performance (IEC 60299:2014) Couvertures chauffantes lectriques usage domestique -Mthodes de mesure des performances (CEI 60299:2014) Elektrische Haushalt-Wrmeunterbetten/Wrmezudecken -Prfverfahren zur Bestimmung der Gebrauchseigenschaften (IEC 60299:2014) This European Stand
6、ard was approved by CENELEC on 2014-08-14. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerni
7、ng such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC membe
8、r into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic
9、of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Co
10、mit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60299:2014 E EN 6029
11、9:2014 - 2 - Foreword The text of document 59C/181/FDIS, future edition 3 of IEC 60299, prepared by SC 59C “Heating appliances“ of IEC/TC 59 “Performance of household and similar electrical appliances“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60299:2014. The follo
12、wing dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-05-14 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-08-14 This doc
13、ument supersedes EN 60299:1994. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Stand
14、ard IEC 60299:2014 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : ISO 3758 NOTE Harmonized as EN ISO 3758. BS EN 60299:2014- 3 - EN 60299:2014 Annex ZA (normative) Nor
15、mative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated refere
16、nces, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards l
17、isted in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60335-2-17 2012 Household and similar electrical appliances - Safety - Part 2-17: Particular requirements for blankets, pads, clothing and similar flexible heating appliances EN 60335-2-17 2013 IEC 62301 (mo
18、d) 2011 Household electrical appliances - Measurement of standby power EN 50564 2011 ISO 2439 - Flexible cellular polymeric materials - Determination of hardness (indentation technique) EN ISO 2439 - BS EN 60299:2014 2 IEC 60299:2014 IEC 2014 CONTENTS 1 Scope 5 2 Normative references 5 3 Terms and d
19、efinitions 5 4 Classification . 7 4.1 General . 7 4.2 Type . 7 4.3 Heated areas 7 4.4 Temperature distribution . 7 4.5 Means of control . 7 4.6 Regulation 7 4.7 Type of supply 8 4.8 Method of cleaning 8 4.9 Fixing of the underblanket to the mattress . 8 5 List of measurements 8 6 General conditions
20、for measurements 8 7 Dimensions, mass and textile composition . 9 7.1 Dimensions . 9 7.2 Mass . 9 7.3 Textile composition . 10 8 Evenness of temperature . 10 9 Heating-up time and energy consumption 12 10 Stability of temperature 12 11 Effect of laundering on dimensions 13 12 Control settings . 13 B
21、ibliography 14 Figure 1 Heated area showing the layout of the plates . 11 BS EN 60299:2014IEC 60299:2014 IEC 2014 5 HOUSEHOLD ELECTRIC BLANKETS METHODS FOR MEASURING PERFORMANCE 1 Scope This International Standard applies to electric blankets, wraps and duvets for household use. This International S
22、tandard defines the main performance characteristics of electric blankets, wraps and duvets and specifies methods for measuring these characteristics, for the information of users. This International Standard does not specify values for performance characteristics. NOTE This standard does not deal w
23、ith safety requirements that are covered by IEC 60335-2-17. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the la
24、test edition of the referenced document (including any amendments) applies. IEC 60335-2-17:2012 Household and similar electrical appliances Safety Part 2-17: Particular requirements for blankets, pads, clothing and similar flexible heating appliances IEC 62301:2011, Household electrical appliances M
25、easurement of standby power ISO 2439, Polymeric materials, cellular flexible Determination of linear dimensions 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 blanket appliance comprising a substantially flat flexible part that is intended t
26、o form part of the bedding, for heating the bed 3.2 flexible part all layers of material forming the permanent enclosure of the appliance together with the heating element, thermostats and all other current-carrying parts contained within it. Note 1 to entry: The flexible part may be inside a detach
27、able cover. 3.3 underblanket blanket to be used under the occupant of the bed 3.4 overblanket blanket to be used over the occupant of the bed BS EN 60299:2014 6 IEC 60299:2014 IEC 2014 3.5 wrap blanket comprising a flexible part intended to be draped over the human body in order to keep it warm 3.6
28、duvet quilted overblanket intended to be used without additional bedding over the occupant of the bed, the heated element providing supplementary heat 3.7 blanket with uniform temperature blanket having an even temperature over the heated area 3.8 blanket with non-uniform temperature blanket in whic
29、h the temperature gradually increases from the head end to the foot end of the heated area 3.9 blanket with a high temperature zone blanket having an even temperature over the major part and having a higher temperature zone generally at the foot end of the heated area 3.10 blanket with ambient tempe
30、rature compensation blanket having a power input which significantly varies inversely with changes in ambient temperature 3.11 heated area area of the flexible part enclosed within the outer perimeter of the heating element or electro-conductive textile Note 1: The heated area includes a margin outs
31、ide the perimeter that has a width equal to 0,5 times the average distance between adjacent runs of the heating element. Note 2: The heated area includes the return length of the heating element if the average distance between this part and the adjacent heating element does not exceed the average di
32、stance between adjacent runs of the heating element. Note 3: If a blanket has two separate areas, the surface between the two areas is considered to be part of the heated areas, if at any place the distance between the two heating elements does not exceed 1,5 times the average distance between adjac
33、ent runs of the heating element 3.12 controlled appliance appliance incorporating means in the flexible part for sensing changes in temperature when the appliance is operated under normal operation, thus automatically controlling the average power input Note 1 to entry: The heated area includes the
34、return length of the heating element if the average distance between this part and the adjacent heating element does not exceed the average distance between adjacent parallel runs of the heating element. Note 2 to entry: If a double blanket has two heating elements which are separately controlled, i
35、t has two heated areas. BS EN 60299:2014IEC 60299:2014 IEC 2014 7 4 Classification 4.1 General The classifications of the appliance are stated. 4.2 Type Electric blankets, wraps and duvets for household use are classified according to their type: underblanket; overblanket; wrap; duvet. 4.3 Heated ar
36、eas Electric blankets, wraps and duvets for household use are classified according to the size and the number of heated areas: single blanket; double blanket with one heated area; double blanket with two heated areas. 4.4 Temperature distribution Electric blankets, wraps and duvets for household use
37、 are classified according to temperature distribution. 4.5 Means of control Electric blankets, wraps and duvets for household use are classified according to the means of control: non-controlled appliance controlled appliance blanket with uniform temperature; blanket with non-uniform temperature; bl
38、anket with a high temperature zone. 4.6 Regulation Electric blankets, wraps and duvets for household use are classified according to means of regulation: blanket without any control; blanket with a control having variable settings; blanket with a control having step settings; blanket with ambient te
39、mperature compensation; BS EN 60299:2014 8 IEC 60299:2014 IEC 2014 4.7 Type of supply Electric blankets, wraps and duvets for household use are classified according to the type of supply: blanket for direct connection to the supply mains; extra low voltage blanket. NOTE An extra low voltage blanket
40、has a rated voltage not exceeding 24 V. 4.8 Method of cleaning Electric blankets, wraps and duvets for household use are classified according to the method of cleaning: washable by hand; machine washable; not washable. 4.9 Fixing of the underblanket to the mattress Electric blankets, wraps and duvet
41、s for household use are classified according to the means of fixing of the underblanket to the mattress: underblanket without means of fixing; underblanket with tie tapes; fitted underblanket. 5 List of measurements Performance is determined by means of the following measurements: dimensions, mass a
42、nd textile composition (Clause 7); evenness of temperature (Clause 8); heating-up time and energy consumption (Clause 9); stability of temperature (Clause 10); effect of laundering (Clause 11); control settings (Clause 12). 6 General conditions for measurements Unless otherwise specified, measuremen
43、ts are made under the following conditions: a) Test room: The tests are carried out in a draught-free room in which the ambient temperature is maintained at 20 C 5 C. b) Supply voltage: The supply voltage is maintained at the rated voltage 1 %. When the appliance is marked with a rated voltage range
44、, the report shall state the voltage used for the test. NOTE 1 If the results obtained by testing the appliance at rated voltage are considered to be misleading due to the national supply voltage, the appliance can also be tested at a voltage corresponding to the nominal voltage of the national supp
45、ly system. BS EN 60299:2014IEC 60299:2014 IEC 2014 9 c) Arrangement of the appliance: Any detachable cover is fitted and the flexible part is placed between sheets of thermal insulation , the size of which is such that the edges extend at least 100 mm beyond the outline of the heated area. d) The th
46、ermal insulation is made of open-cell polyether having: cell count 18 + 2 per cm; specific mass 30 kg/m3+10 %; hardness between 120 N and 170 N at 40 % impression measured according to ISO 2439. The thermal insulation is supported over its entire area by a piece of plywood 20 mm thick, situated not
47、less than 300 mm above the floor. The thickness of the thermal insulation under the appliance is approximately 72 mm and over the appliance approximately no material for duvets, 7,2 mm for overblankets and wraps, 36 mm for underblankets NOTE 2 The specification of the thermal insulation is taken fro
48、m IEC 60335-2-17:2012, Annex AA. The above specified thickness of the thermal insulation is for reference; the exact thickness shall be calibrated as specified in IEC 60335-2-17:2012, Annex AA. 7 Dimensions, mass and textile composition 7.1 Dimensions The dimensions of the flexible part of the appli
49、ance and the heated area are 7.1.1determined. The dimensions of a washable detachable cover are also determined in order to 7.1.2assess the effect of laundering. The appliance is spread out without tension on a flat surface and the length and width are measured. The average values for each dimension are calculated. The dimensions are stated in millimetres (mm), rounded to the nearest 10 mm. The lengths of flexible cords are determined. 7