DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf

上传人:fuellot230 文档编号:664243 上传时间:2018-12-26 格式:PDF 页数:40 大小:1.05MB
下载 相关 举报
DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf_第1页
第1页 / 共40页
DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf_第2页
第2页 / 共40页
DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf_第3页
第3页 / 共40页
DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf_第4页
第4页 / 共40页
DIN EN 12050-2-2015 Wastewater lifting plants for buildings and sites - Part 2 Lifting plants for faecal-free wastewater German version EN 12050-2 2015《建筑物和现场用废水提升装置 第2部分 无粪便废水的提升装.pdf_第5页
第5页 / 共40页
点击查看更多>>
资源描述

1、May 2015 Translation by DIN-Sprachendienst.English price group 16No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91

2、.140.80!%B_“2316060www.din.deDDIN EN 12050-2Wastewater lifting plants for buildings and sites Part 2: Lifting plants for faecal-free wastewater;English version EN 12050-2:2015,English translation of DIN EN 12050-2:2015-05Abwasserhebeanlagen fr die Gebude- und Grundstcksentwsserung Teil 2: Abwasserhe

3、beanlagen fr fkalienfreies Abwasser;Englische Fassung EN 12050-2:2015,Englische bersetzung von DIN EN 12050-2:2015-05Stations de relevage deffluents pour les btiments et terrains Partie 2: Stations de relevage pour effluents exempts de matires fcales;Version anglaise EN 12050-2:2015,Traduction angla

4、ise de DIN EN 12050-2:2015-05SupersedesDIN EN 12050-2:2001-05See start of applicationwww.beuth.deDocument comprises 40 pagesIn case of doubt, the German-language original shall be considered authoritative.04.15 DIN EN 12050-2:2015-05 2 A comma is used as the decimal marker. Start of application The

5、start of application of this standard is 2015-05-01. It should be noted that, in Germany, CE conformity marking of construction products will be permitted once this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette) and from the

6、date given therein. For further information, users of this standard should refer to the websites of the European Commission or of the relevant building authority. The standard which this document replaces, DIN EN 12050-2:2001-05, may be used in parallel with this standard during a specified transiti

7、on period where such has been laid down in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette). National foreword This document (EN 12050-2:2015) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering” (Secretariat: DIN, Germany). The p

8、reliminary work was done by Working Group WG 21 “Drainage systems inside buildings”. The responsible German body involved in its preparation was the DIN-Normenausschuss Wasserwesen (DIN Standards Committee Water Practice), Working Committee NA 119-05-23 AA Abwasserhebeanlagen. Amendments This standa

9、rd differs from DIN EN 12050-2:2001-05 as follows: a) Subclause 4.7 “Reaction to fire” has been added; b) Subclause 5.2.3 “Hot water test” has been added; c) Clause 6 “Assessment and verification of constancy of performance AVCP” has been updated in accordance with EU Construction Products Regulatio

10、n No 305/2011 (CPR); d) Annex ZA has been updated in accordance with EU Construction Products Regulation No 305/2011 (CPR); e) the standard has been editorially revised. Previous editions DIN EN 12050-2: 2001-05 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12050-2 March 2015 ICS 91.140.80 Su

11、persedes EN 12050-2:2000English Version Wastewater lifting plants for buildings and sites - Part 2: Lifting plants for faecal-free wastewater Stations de relevage deffluents pour les btiments et terrains - Partie 2: Stations de relevage pour effluents exempts de matires fcales Abwasserhebeanlagen fr

12、 die Gebude- und Grundstcksentwsserung - Teil 2: Abwasserhebeanlagen fr fkalienfreies Abwasser This European Standard was approved by CEN on 17 January 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the

13、 status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, Frenc

14、h, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria,

15、Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey a

16、nd United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref.

17、No. EN 12050-2:2015 EEN 12050-2:2015 (E) 2 Contents Page Foreword 4 1 Scope 5 2 Normative references 5 3 Terms, definitions, symbols and abbreviations .6 3.1 Terms and definitions .6 3.2 Symbols and abbreviations 7 3.2.1 Symbols 7 3.2.2 Abbreviations .7 4 Material and product characteristics .7 4.1

18、Materials .7 4.2 Collection tank .7 4.2.1 Mechanical resistance .7 4.2.2 Watertightness .7 4.3 Lifting effectiveness 8 4.3.1 Pumping of solids 8 4.3.2 Pipe connections .8 4.3.3 Ventilation .8 4.3.4 Minimum flow rate .8 4.3.5 Minimum allowable solids passage of the lifting plant9 4.3.6 Minimum size o

19、f the discharge connection 9 4.3.7 Useful volume 9 4.4 Control equipment 10 4.5 Electrical equipment . 10 4.6 Fixing devices . 10 4.7 Reaction to fire 10 4.7.1 General . 10 4.7.2 Plants classified as Class A1 without the need for testing 10 4.7.3 Plants classified according to test results . 11 4.8

20、Noise level . 11 4.9 Durability . 11 4.9.1 General . 11 4.9.2 Durability of Watertightness 12 4.9.3 Durability of lifting effectiveness 12 4.9.4 Durability of mechanical resistance . 12 4.10 Dangerous substances 12 4.11 Need for a stand-by pumping device (twin lifting plant). 12 5 Testing . 13 5.1 P

21、reparation 13 5.1.1 General requirements . 13 5.1.2 Testing for hydraulic performance . 13 5.2 Tightness testing 13 5.2.1 Watertightness 13 5.2.2 Connection to the discharge pipe . 13 5.2.3 Hot water test 13 5.3 Lifting effectiveness . 14 6 Assessment and verification of constancy of performance - A

22、VCP . 14 6.1 General . 14 DIN EN 12050-2:2015-05 EN 12050-2:2015 (E) 3 6.2 Type testing . 15 6.2.1 General . 15 6.2.2 Test samples, testing and compliance criteria 15 6.2.3 Test reports 16 6.2.4 Shared other party results 16 6.2.5 Cascading determination of the product type results . 17 6.3 Factory

23、production control (FPC) 18 6.3.1 General . 18 6.3.2 Requirements . 18 6.3.3 Product specific requirements . 21 6.3.4 Initial inspection of factory and of FPC only for products covered by AVCP system 1 22 6.3.5 Continuous surveillance of FPC only for products covered by AVCP system 1 . 22 6.3.6 Proc

24、edure for modifications. 23 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity . 23 7 Marking, labelling and packaging 24 7.1 Manufacturers declaration . 24 7.2 Marking . 24 8 Manufacturers instructions for installation, operation and mainten

25、ance 24 Annex A (informative) Recommended Materials 25 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 26 ZA.1 Scope and relevant characteristics . 26 ZA.2 Procedure for AVCP of lifting plants for faecal free wastewater 28

26、 ZA.2.1 System(s) of AVCP 28 ZA.2.2 Declaration of performance (DoP) . 31 ZA.2.2.1 General 31 ZA.2.2.2 Content 32 ZA.2.2.3 Example of DoP 33 ZA.3 CE marking and labelling 35 Bibliography 38 DIN EN 12050-2:2015-05 EN 12050-2:2015 (E) 4 Foreword This document (EN 12050-2:2015) has been prepared by Tec

27、hnical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2015 and conflicting national standards sha

28、ll be withdrawn at the latest by December 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12050-2:20

29、00. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the works basic requirements of the Regulation (EU) No. 305/2011. For relationship with EU Regulation, see informative Annex ZA, which is an integral part

30、 of this document. The standard series EN 12050 “Wastewater lifting plants for buildings and sites” consists of the following parts: Part 1: Lifting plants for wastewater containing faecal matter Part 2: Lifting plants for faecal-free wastewater Part 3: Lifting plants for limited applications Part 4

31、: Non-return valves for faecal-free wastewater and wastewater containing faecal matter The main changes with respect to the previous edition are listed below: a) reaction to fire added; b) hot water test added; c) paragraph title “Evaluation of conformity” changed to “Assessment and verification of

32、constancy of performance AVCP” and updated in accordance with “Implementation of the Construction Products Regulation (CPR) in harmonized standards”; d) Annex ZA updated in accordance with “Implementation of the Construction Products Regulation (CPR) in harmonized standards” (adoption of the Regulat

33、ion EU No. 305/2011); e) editorially revised. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Form

34、er Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 12050-2:2015-05 EN 12050-2:2015 (E

35、) 5 1 Scope This European Standard applies to lifting plants for faecal-free wastewater for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembl

36、ed on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance. Construction and testing requirements for non-return valves used in wastewater lifting plants are g

37、iven in EN 12050-4. This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F. This European Standard applies also to lifting plants for faecal-free wastewater which are not pref

38、abricated but composed of individual components purchased from different suppliers and put together on site. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edit

39、ion cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 124, Gully tops and manhole tops for vehicular and pedestrian areas Design requirements, type testing, marking, quality control EN 12056-1, Gravity drainage systems inside

40、buildings Part 1: General and performance requirements EN 12056-4, Gravity drainage systems inside buildings Part 4: Wastewater lifting plants, layout and calculation EN 12566-1:2000/A1:2003, Small wastewater treatment systems for up to 50 PT Part 1: Prefabricated septic tanks EN 12566-4:2007, Small

41、 wastewater treatment systems for up to 50 PT Part 4: Septic tanks assembled in situ from prefabricated kits EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13823, Reaction to fire tests for building prod

42、ucts Building products excluding floorings exposed to the thermal attack by a single burning item EN 60529, Degrees of protection provided by enclosures (IP code) (IEC 60529) EN ISO 9906:2012, Rotodynamic pumps Hydraulic performance acceptance tests Grades 1, 2 and 3 (ISO 9906:2012) EN ISO 20361, Li

43、quid pumps and pump units Noise test code Grade 2 and grade 3 of accuracy (ISO 20361) DIN EN 12050-2:2015-05 EN 12050-2:2015 (E) 6 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 domestic wa

44、stewater water which is contaminated by use and normally discharged from WC, showers, baths, bidets, wash basins, sinks and floor gullies SOURCE: EN 12056-1:2000, 3.1.2 3.1.2 lifting plant for faecal-free wastewater device for the collection and automatic lifting of faecal-free wastewater to a heigh

45、t above flood level Note 1 to entry: A non-return valve according to EN 120504 is a component of the plant. 3.1.3 collection tank for faecal-free wastewater unpressurized part of a faecal-free lifting plant in which the incoming wastewater is stored prior to lifting 3.1.4 site area in the proximity

46、of the building outside buildings Note 1 to entry: For further explanation see EN 120561:2002, Figure 1 3.1.5 useful volume volume in the collection tank between switch-on level and switch-off level SOURCE: EN 12050-1:2015, definition 3.1.5 3.1.6 flood level maximum level to which waste water can ri

47、se within a drainage system SOURCE: EN 12056-1:2000, 3.1.7 3.1.7 pumping device for faecal-free wastewater component of a faecal-free lifting plant which pumps the wastewater out of the collection tank to a height above flood level 3.1.8 maximum pump operating pressure maximum hydrostatic pressure t

48、hat the pumping device is capable to create 3.1.9 ball passage passage where a ball with a defined diameter can pass through without deformation 3.1.10 warning device device which gives a signal if a malfunction occurs DIN EN 12050-2:2015-05 EN 12050-2:2015 (E) 7 3.2 Symbols and abbreviations 3.2.1 Symbols dipipe internal diameter, in mm Q flow rate, in l/s H discharge head, in m v flow velocity, in m/s 3.2.2 Abbreviations AVCP assessment and verification of constancy of performance DN nomi