1、Beneficial comments recommendations, additions, deletions, clarifications, etc., and any data which may improvethis document should be addressed to: Defense Supply Center, Columbus, ATTN: DSCC-VAT, Post Office Box3990, Columbus, OH 43213-1199, or telephone (614) 692-0562, or facsimile (FAX) (614) 69
2、3-1644.AMSC N/A FSC 5915DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.INCH-POUNDA-A-55506ASeptember 17, 2001SUPERSEDINGA-A-55506BDecember 25, 1993COMMERCIAL ITEM DESCRIPTIONFILTER, RADIO FREQUENCY INTERFERENCEThe General Services Administration has authorized the u
3、seof this commercial item description (CID) for all federal agencies.1. SCOPE. This CID covers the general requirements for radio frequency interference (RFI) suppression power linefilters. These filters consist of capacitors and inductors used in combination with each other and are provided withres
4、istors as a safety feature. This series of RFI filters incorporate the special international ElectrotechnicalCommission (IEC) power line connector. Filters covered by this CID are intended for commercial/industrialapplications and should not be used in military systems needing stringent environmenta
5、l and electrical requirements.2. CLASSIFICATION. This CID uses a classification system which is included in the Part Identification Number(PIN) as shown in the following example (see 7.1).AA55506 -01CID number Dash number3. SALIENT CHARACTERISTICS.3.1 Interface and physical dimensions. Filters suppl
6、ied to this CID shall be as specified herein (see figures 1 and 2).3.2. Voltage rating. The voltage rating shall be 120 V ac at 60 Hz; 250 V ac at 50 Hz.3.3 Operating frequency. The operating frequency shall be 50/60 Hz.3.4 Current rating. The current rating shall be as specified in table I.3.5 Oper
7、ating ambient temperature range. The operating ambient temperature range shall be -10G01C to +40G01C atrated current.3.6 Maximum leakage current, line-to-ground. The maximum leakage current for configuration 1, line-to-ground,shall be 0.25 mA at 120 V ac, 60 Hz; .50 mA at 250 V ac, 50 Hz. The maximu
8、m leakage current for configuration 2,line-to-ground, shall be 0.5 mA at 120 V ac, 60 Hz; 1.0 mA at 250 V ac, 50 Hz.3.7 Hipot rating (1 minute). The hipot rating shall be 2,250 V dc line-to-ground; 1,450 V dc line-to-line.3.8 Insertion loss. Insertion loss is given for line-to-ground in a 50-ohm cir
9、cuit. Values shall be as specified in table I.3.9 Electrical schematics. The electrical schematics shall be as specified on figure 1.3.10 Marking. Filters supplied to this CID shall be marked with the manufacturers (MFRs) standard commercialPIN.Provided by IHSNot for ResaleNo reproduction or network
10、ing permitted without license from IHS-,-,-A-A-55506A2TABLE I. Current rating and insertion loss.Minimum insertion loss (dB)Line-to-ground in 50-ohm circuitMinimum insertion loss (dB)Line-to-line 50-ohm circuitPINAA55506-CurrentratingLeakagecurrentconfig. Frequency (MHz).15 .5 1 5 10 30Frequency (MH
11、z).15 .5 1 5 10 3001 3 A 2 15 30 38 50 50 50 - - 48 55 50 3502 1/ 3 A 2 15 30 38 50 50 50 - - 48 55 50 3503 3 A 1 15 29 35 45 45 50 - - 48 55 50 3504 1/ 3 A 1 15 29 35 45 45 50 - - 48 55 50 3505 5 A 2 6 19 28 42 45 50 - - 30 50 30 3006 1/ 5 A 2 6 19 28 42 45 50 - - 30 50 30 3007 5 A 1 8 19 25 38 40
12、45 - - 30 50 30 3008 1/ 5 A 1 8 19 25 38 40 45 - - 30 50 30 3009 10 A 2/ 2 6 19 28 42 45 50 - - 30 50 30 3010 1/ 10 A 2/ 2 6 19 28 42 45 50 - - 30 50 30 3011 10 A 2/ 1 8 19 25 38 40 45 - - 30 50 30 3012 1/ 10 A 2/ 1 8 19 25 38 40 45 - - 30 50 30 301/ Equipped with metric insert.2/ Limited to 6 amper
13、es at 250 V ac by IEC connector.FIGURE 1. Electrical schematic.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55506A3A(max)B(max)C(max)DG02.015/G02.38E(max)PINAA55506-Inch mm Inch mm Inch mm Inch mm Inch mm01, 02 3.21 81.5 2.25 57.2 1.28 32.5 1.
14、575 40.01 .63 16.003, 04 3.21 81.5 2.25 57.2 1.28 32.5 1.575 40.01 .63 16.005, 06 3.21 81.5 2.25 57.2 1.28 32.5 1.575 40.01 .63 16.007, 08 3.21 81.5 2.25 57.2 1.28 32.5 1.575 40.01 .63 16.009, 10 3.71 94.2 2.25 57.2 1.28 32.5 1.575 40.01 .63 16.011, 12 3.71 94.2 2.25 57.2 1.28 32.5 1.575 40.01 .63 1
15、6.0NOTES:1. Dimensions are in inches.2. Metric equivalents are given for general information only.3. Fastons: (Three) .250 inch (6.35 mm). Holes: .07 inch (1.8 mm) diameter.4. Thread sizes: No. 6-32 x .250 (M-3 x .5) (2).5. Metric equivalents are in parentheses.FIGURE 2. Case configuration and dimen
16、sions.Inches mm.005.07.157.235.250.091.2951.5750.131.83.985.966.3523.132.8940.01Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55506A44. REGULATORY REQUIREMENTS. The offeror/contractor is encouraged to use recovered materials to themaximum exten
17、t practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR).5. PRODUCT CONFORMANCE PROVISIONS5.1 Product conformance. The products provided shall meet the salient characteristics of this CID, conform to theproducers own drawings, specifications, standards, and qual
18、ity assurance practices, and be the same productoffered for sale in the commercial market. The Government reserves the right to require proof of such conformance.6. PACKAGING. Preservation, packing, and marking shall be as specified in the contract or order.7. NOTES.7.1 PIN. The PIN should be used f
19、or Government purposes to buy commercial products to this CID. See section 2for PIN format example.7.2 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and submission ofthese filters to DSCC under the Military Parts control Advisory Group (MPCAG) evaluation pro
20、gram, CAGE code58536 should be used.7.3 Source of documents. This section is not applicable to this CID.7.4 Ordering data. The contract or order should specify the following:a. CID document number, revision, and CID PIN.b. Product conformance provisions.c. Packaging requirements.7.5 Commercial produ
21、cts. As part of the market analysis and research effort, this CID was coordinated with thefollowing manufacturers of commercial products. At the time of CID preparation and coordination, thesemanufacturers were known to have commercial products that would meet the requirements of this CID. (NOTE:Thi
22、s information should not be considered as a list of approved manufacturers or be used to restrict procurement toonly the manufacturers shown.)MFRs CAGE MFRs name and address0S2B1 RME Filters, IncorporatedP. O. Box 83898 Route 101 AAmherst, NH 03031-083805245 CORCOM, Incorporated844 East Rockland Roa
23、dLibertyville, IL 6004864135 Filter Concepts, Incorporated2624 S. Rousselle StreetSanta Ana, CA 92707Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55506A57.6 Part number (PIN) supersession data. This CID supersedes the following manufacturers P
24、INs as shown. Thisinformation is being provided to assist in reducing proliferation in the government inventory system.TABLE II. P/N supersession data.MFRs CAGE0S2B1MFRs CAGE64135MFRs CAGE05245PINAA55506- MFRs Commercial PIN 1/01 RME-A-203-C - 3VK702 RME-A-203-C-1 - 3VK7M03 RME-A-203-C-2 - 3EK704 RM
25、E-A-203-C-3 - 3EK7M05 RME-A-205-C LE5C 5VK706 RME-A-205-C-1 - 5VK7M07 RME-A-205-C-2 LE5C 5EK708 RME-A-205-C-3 - 5EK7M09 RME-A-210-C - 10VK710 RME-A-210-C-1 - 10VK7M11 RME-A-210-C-2 - 10EK712 RME-A-210-C-3 - 10EK7M1/ The manufacturers PIN shall not be used for procurement to the requirements of this
26、CID.At the time of preparation of this CID, the aforementioned commercial products were reviewedand could be replaced by the CID PIN shown. For actual part marking requirements, see 3.11.7.7 Government users. To acquire information on obtaining these filters from the Government inventory system,cont
27、act Defense Supply Center Columbus, ATTN: DSCC-VAT, Post Office Box 3990, Columbus, OH 43216-5000,telephone (614) 692-0562 or facsimile (614) 693-1644.7.7.1 National stock number (NSN). The following is a list of NSNs assigned which correspond to this CID. The listis for information only and may not
28、 be indicative of all possible NSNs associated with the CID. For up to dateinformation on assigned NSNs, please contact the aforementioned DSCC office (See 7.7).MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY:GSA - 7FXECustodians:Navy - EC Preparing Activity:DLA-CCProject 5915-0410Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-