1、_ MIL-PRF-L/LOObE 9999906 2062i143 537 I Parameter: Ef Ecl Ebl Eb2 Eb3 ed Rg Zd Ehk Unit: V Vdc Vdc Vdc il Vdc V Meg Meg Vdc Maximum: 6.9 O 1,500 3,000 6,000 750 1.5 1 .o 51 80 Minimum: 5.7 -200 - 1,000 2,000 - -_ Test 31 _- II _ I_ _ INCH-POUND I MIL-PRF-I/1006E 9 March 1998 SUPERSEDING 3 January 1

2、977 MIL-E-111 006D Eb3lEb2 Ratio 3/ 2.0 2.0 3n PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPE 4DP7 This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the electron tube described herein shall consist o

3、f this document and the latest issue of MIL-PRF-1. DESCRIPTION: Square face, two gun, electrostatic deflection and focus. DIMENSIONS AND PIN CONNECTIONS See figure 1. - 11 - 2/ Accelerator power input (average) should be limited to 6 watts. It is recommended that the deflection electrode circuit res

4、istance be approximately equal. Higher resistance values up to 5.0 megohms may be used for low-beam current operation. This tube is designed for optimum performance when operating at an Eb3/Eb2 ratio of 2.0. Operation at other ratios of Eb3iEb2 may result in changes in deflection uniformity, pattern

5、 distornion, and tracking accuracy. All tests except capacitance, vibration, and interaction factor shall be made on each unit separately. Each deflection plate shall be connected to A2 through a resistance of 1 megohm. - 3i - 41 GENERAL: Qualification - Required. AMSC NA 1 of6 DISTRIBUTION STATEMEM

6、 A. Approved for public release: distribution is unlimited. FSC 5960 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-l/lOObE Ob 2062444 473 MIL-PRF-111006E TABLE I. Testinq and inspection. Inspection ualification inspection Vibration Cathode

7、 illumination z/ Neck and bulb alignment (electrostatic types) DeR ide terminal alignment (electrostatic types) (electrostac types) (electrostatic types) ;ide terminal and base alignment Jeck and base alignment rrace and bulb alignment I/ (electrostatic types) Ingle between traces rrace alignment a

8、rrace cuwahire radius Stray light emission Screens g/ Line width “A“ (electrostatic deflection) deflection) Line width B“ (electrostatic Focusing voltage at cutoff Focusing voltage at modulation condition Deflection factor Deflection factor Heatercathode leakage current Grid No. 1 leakage current An

9、ode No. 1 leakage current Anode No. 2 leakage current Secureness of base, cap. or inseri Base pin solder depth ee footnotes at end of table. MlL-PRF-l/1006E TABLE I. Testina and insDection -Continued. Method 5101 51 O1 5101 5101 -_ 51 O1 I I 521 6 522 1 5226 5226 5246 5246 5248 5248 5251 5251 5251 5

10、251 1101 1111 Conditions b1 D2, pin No. 4 11 02 in No. 4 Eb2 = 3,000 V dc; Eb3 = 6,000 V dc 1 D2 304 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-L/LOObE = 9999906 2062446 246 MIL-PRF-l/1006E TABLE I. Testinq and inspection - Continued.

11、 Inspection Conformance inspection, pari 2 - Continued Permanence of marking Conformance inspection. pari 3 Life test Life test end points: Modulation Line width “A“ Line width “ Method 1105 - 5223 5226 5226 Conditions Group C; t = 500 hwrs (min); Eb3 = 6,000 V; both guns operating lb3 = 15 pA dc; E

12、b2 = 3,000 V; lb3 = 20 pA dc Symbol _ -_ AEcl width Width - 1/ Alignment between any trace and the parallel edge of the faceplate shall not exceed the indicated value - 21 The angle between corresponding traces of each gun shall not exceed the indicated value. - 3/ The measurement shall be made with

13、 both filaments operating simultaneously. - 4/ The raster size shall be 4.1 x 4.1 cm. The screen current shall be adjusted to 20 pA dc. Add 48 CB to the reading to correct for the smaller raster area. - 5/ With focused, undeflected spot and the tube shielded against extemal influences the spots will

14、 fall within a 13 mm square, the center of which coincides with the geometric center of the tube face and the sides of which are parallel to the traces produced by the various deflecting electrodes. - 61 The useful scan will be a 2.875 inches (73.03 mm) square having rounded comers. The maximum radi

15、us of curvature of the rounded corners of the square screen area shall be 0.6 inch (1 5.24 mm). - 7/ All other electrodes contained within the envelope are to be tied together. - 8/ The measurement of tracking error shall be made as follows: The focused spots of both guns shall be moved by means of

16、a common dc voltage along the 1 D2 axis until the spot of gun A is at +0.719 inch (+18.26 mm) from the geometric center of the tracking area. Then by means of a small correction voltage the spot of gun B shall be moved to the same distance. The spots then shall be moved by means of the common dc vol

17、tage in the opposite direction from the geometric center until the spot of the less sensitive gun reaches -0.719 inch (-18.26 mm). The difference in deflection factor of the more sensitive gun is then compensated for by moving its spot back to -0.71 9 inch (-1 8.26 mm) inch by means of a voltage div

18、ider. This entire procedure is to be duplicated along the 3D4 axis with a distance from the geometric center of f 0.562 inch (f14.29 mm). Then by means of the two common dc voltages the spots shall be tracked over the entire tracking area, a 2.875 inches (73.03 mm) (1 D2) x 2.25 inches (57.15 mm) (3

19、D4) rectangle, and the greatest distance between the spots shall not exceed the limit specified. - 9/ The maximum distance along the vercai or horizontal axis shall not exceed the value specified. - 1 O/ This test to be performed at the conclusion of the holding period. 4 Provided by IHSNot for Resa

20、leNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-L/LUObE 9999906 2062447 182 Ltr C A Dimensions Inches I Millimeters NOTE: +3D4 Index key +1 D2 toward pin 4 M BOTTOII VIEW OF BASE CONNECTION SEE NOTE Min Max Min IMax Base: 812-37 B C E I Qualification inmection I 3.437

21、3.563 87.30 90.50 3.437 3.563 87.30 90.50 2.875 - 73.02 - - G 4.156 H 1.500 J 4.125 IA1 12.000 I 12.500 I 304.80 I 317.50 I 4.344 105.56 110.34 1.750 38.10 44.45 4.875 104.78 123.83 KI 6.000 I 6.375 I 152.40 I 161.93 LI 2.969 I 3.031 I 75.41 I 76.99 FIGURE 1. Outline drawina of electron tube me 4DP7

22、 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Custodians: Navy - EC Air Force - 85 AINIY - CR MIL-PRF-L/100bE m 99999Ob 20b2448 O19 m Preparing activity: DU - CC (Project 5960-3466-61 ) Review activities: Amy - CR4 Navy - AS, CG. MC, OS. Air Force - 17, 99 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-