DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf

上传人:吴艺期 文档编号:693083 上传时间:2018-12-30 格式:PDF 页数:13 大小:112.53KB
下载 相关 举报
DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf_第1页
第1页 / 共13页
DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf_第2页
第2页 / 共13页
DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf_第3页
第3页 / 共13页
DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf_第4页
第4页 / 共13页
DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf_第5页
第5页 / 共13页
点击查看更多>>
资源描述

1、 MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, DC COILS This specification is approved for use by all

2、 Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and the latest issue of MIL-PRF-83536. FIGURE 1. Dimensions and configurations. AMSC N/A FSC 5945 INCH-POUND Ltr Inches Millimeters Min Max Mi

3、n Max A - .810 - 20.57 B - .640 - 16.26 C .140 TYP .160 TYP 3.56 TYP 4.06 TYP D - .810 - 20.57 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 2 FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo rep

4、roduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 3 FIGURE 1. Dimensions and configurations - Continued. Ltr Inches Millimeters Min Max Min Max A - .810 - 20.57 B - .640 - 16.26 C .015 .035 0.38 0.89 D .146 .166 3.71 4.22 E - 1.280 - 32.51 F 1.068 1.088 27.13 27.64 G 1.

5、052 1.072 26.72 27.23 H .140 TYP .160 TYP 3.56 TYP 4.06 TYP J .702 .722 17.83 18.34 K .140 TYP .160 TYP 3.56 TYP 4.06 TYP L .131 TYP .151 TYP 3.33 TYP 3.84 TYP M .240 .260 6.10 6.60 N .490 .510 12.45 12.95 P - .810 - 20.57 Q .123 TYP .143 TYP 3.12 TYP 3.63 TYP R 1.060 1.080 26.92 27.43 S .840 .860 2

6、1.34 21.84 T .100 .120 2.54 3.05 U .415 .435 10.54 11.05 V .840 .860 21.34 21.84 W .021 R .041 R 0.53 R 1.04 R X 490 .510 12.45 12.95 Y .240 .260 6.10 6.60 Z .137 .143 3.48 3.63 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 4 FIGUR

7、E 1. Dimensions and configurations - Continued Ltr Inches Millimeters Min Max Min Max A - 1.280 - 32.51 B 1.068 1.088 27.13 27.64 C 1.052 1.072 26.72 27.23 D - .810 - 20.57 E - .640 - 16.26 F .131 TYP .151 TYP 3.33 TYP 3.83 TYP G .395 .415 10.03 10.54 H .590 .610 14.99 15.49 J .123 TYP .143 TYP 3.12

8、 TYP 3.63 TYP K - .810 - 20.57 L .140 TYP .160 TYP 3.56 TYP 4.06 TYP M .015 .035 0.38 0.89 N 140 TYP .160 TYP 3.65 TYP 4.06 TYP P 1.060 1.080 26.92 27.43 Q .137 .143 3.48 3.63 R .395 .415 10.03 10.54 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI

9、L-PRF-83536/5C 5 FIGURE 1. Dimensions and configurations - Continued. Ltr Inches Millimeters Min Max Min Max A .038 .042 0.96 1.07 B .160 .180 4.06 4.57 C .038 .042 0.96 1.07 D - .210 - 5.33 E .160 .180 4.06 4.57 F .038 .042 0.96 1.07 Provided by IHSNot for ResaleNo reproduction or networking permit

10、ted without license from IHS-,-,-MIL-PRF-83536/5C 6 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a suitable legible circuit diagram that identifies

11、each terminal location specified. 5. These relays are polarized monstable. 6. This relay shall not operate or be damaged by reverse polarity. 7. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electro-magnet flux. 8. Applicable to horizontal fl

12、ange mount only. The circuit diagram, manufacturers PIN, and the military PIN shall be marked on the near side. The remaining portion of the nameplate data shall be marked on the far side. 9. Applicable to horizontal flange mount only. Relays shall be marked with the manufacturers name or CAGE code

13、and date code. Marking shall be with the bottom of the print adjacent to the near side. 10. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Terminal, except the polarizing pin, shall be gold-

14、plated. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity.

15、 11. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 15 to 35, thickness .050 .005. Gasket material according to SAE-AMS3332 ha

16、s been considered acceptable. 12. Indicated terminal shall be identified by a contrasting bead. 13. Plane of critical motion for vibration and shock is Y-axis. FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

17、om IHS-,-,-MIL-PRF-83536/5C 7 REQUIREMENTS: Contact data: Load ratings: See table I. Low level: 10 A to 50 A at 10 mV dc to 50 mV dc or peak ac. Intermediate current: Applicable. Mixed loads: Applicable. TABLE I. Rated contact load and cycles (amperes per pole). Type of load (high level) Cycles x 10

18、3 28 V dc 115 V ac 1 phase 400 Hz 115/200 V ac 3 phase 400 Hz Resistive 100 5 5 5 Inductive 20 3 5 5 Motor 100 2 3 3 Lamp 100 1 N/A N/A Life: 100,000 cycles, unless otherwise specified (see table I). Contact voltage drop or resistance: Initial contact voltage drop: 0.100 volt maximum. Rated resistiv

19、e current at 6 V dc or peak ac. Relays shall not make or break this load. Initial contact resistance: 0.050 ohm maximum. 50 mA max at 6 V dc or peak ac. High level life (contact voltage drop): During life: 10 percent open circuit voltage maximum. After life: 0.125 volt maximum. Intermediate current

20、(contact resistance): During intermediate current: 3 ohms maximum. After intermediate current: 0.150 ohm maximum. Low level (contact resistance): During low level: 100 ohms maximum. After low level: 0.150 ohm maximum at 100 mA and 28 V dc. Contact bounce: 1.0 millisecond maximum. Contact stabilizati

21、on time: 2.5 milliseconds maximum. Overload current: 20 amperes dc, 30 amperes ac. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 8 Rupture current: 25 amperes dc, 40 amperes ac. Time current relay characteristics: See table II. TAB

22、LE II. Time current relay characteristics. 1/ Successive application Amperes Time 1 10 1 hour 2 15 20 seconds 3 37.5 2 seconds 4 75 .53 second 1/ All relays shall withstand overload and fault currents. Relays must be able to sustain five applications (make and carry only) of power concurrently on ad

23、jacent poles at each of four different current levels in the sequence listed in table II. Separate relays shall be tested at 28 V dc and 115/200 V ac, 400 Hz 3-phase. Cooling time between successive applications shall be 30 minutes. Tests shall be performed on both normally open and normally closed

24、contacts. There shall be no failures or evidence of welding or sticking and relays shall pass contact voltage drop at the conclusion. Coil data 1/: See table III. Operate time: 6 milliseconds maximum with rated coil voltage at 25C. 7 milliseconds maximum with rated coil voltage over the temperature

25、range. Release time: 6 milliseconds maximum from rated coil voltage at 25C. 7 milliseconds maximum from rated coil voltage over the temperature range. Duty rating: Continuous. Coil transient suppression: Not applicable. Neutral screen: Not applicable. Electrical data: Insulation resistance: Initial:

26、 100 megohms at 500 V dc. After life or environmental tests: 50 megohms at 500 V dc. 1/ CAUTION: Due to possible interaction of relay magnetic fields, the following spacing requirements, as a minimum, shall be considered in dense packaging situations: a. Row to row assisting fields: .125 (3.18 mm).

27、b. Row to row opposing fields: .1875 (4.763 mm). c. Side to side alternating fields: .0625 (1.588 mm). d. Side to side like fields: .125 (3.18 mm).Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C9 TABLE III. Dash numbers and character

28、istics. 1/ Dash number 2/ Mount Coil data At 25C Over temperature range Maximum pickup voltage Solder pin Solder hook Socket pin Coil voltage (V dc) 3/ Coil resistance (ohms) (minimum) Specified pickup voltage (V dc) 4/ Specified hold voltage (V dc) 4/ Specified dropout voltage (V dc) 4/ Specified p

29、ickup voltage (V dc) 4/ Specified hold voltage (V dc) 4/ Specified dropout voltage (V dc) 4/ High temperature test Continuous current test Rated Max 001 002 003 No mount 6 7.3 15 3.3 1.6 0.4 4.5 2.3 0.25 5.0 5.7 004 005 006 RVFM 6 7.3 15 3.3 1.6 0.4 4.5 2.3 0.25 5.0 5.7 007 008 - HFM 6 7.3 15 3.3 1.

30、6 0.4 4.5 2.3 0.25 5.0 5.7 009 010 011 No mount 12 14.5 70 6.6 3.3 0.75 9.0 4.5 0.5 9.9 11.25 012 013 014 RVFM 12 14.5 70 6.6 3.3 0.75 9.0 4.5 0.5 9.9 11.25 015 016 - HFM 12 14.5 70 6.6 3.3 0.75 9.0 4.5 0.5 9.9 11.25 017 018 019 No mount 28 5/ 29 360 13.5 5.5 2.3 18.0 7.0 1.5 19.8 22.5 020 021 022 R

31、VFM 28 5/ 29 360 13.5 5.5 2.3 18.0 7.0 1.5 19.8 22.5 023 024 - HFM 28 5/ 29 360 13.5 5.5 2.3 18.0 7.0 1.5 19.8 22.5 025 026 027 No mount 48 50 1125 24.0 10.0 3.0 36.0 12.0 2.4 40.0 44.0 028 029 030 RVFM 48 50 1125 24.0 10.0 3.0 36.0 12.0 2.4 40.0 44.0 031 032 - HFM 48 50 1125 24.0 10.0 3.0 36.0 12.0

32、 2.4 40.0 44.0 1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6 V dc maximum or peak ac open circuits are not recommended for subsequent use in low level applications. 2/ The suffix letter L, M, P, or R to designate t

33、he applicable failure rate level shall be added to the applicable listed dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example: 001L, 002R. 3/ CAUTION: The use of any coil voltages less than the rated coil voltage will compromise the operation of the r

34、elay. 4/ Pickup, hold, and dropout voltages as shown are for test purposes only and are not to be used for design criteria. 5/ When maximum ambient temperature does not exceed +85C, the maximum coil voltage shall be 32 V dc. Provided by IHSNot for ResaleNo reproduction or networking permitted withou

35、t license from IHS-,-,-MIL-PRF-83536/5C 10 Dielectric withstanding voltage 2/: Coil to case All other points Sea level: Initial: 1,000 1,000After life: 750 750 Altitude: At 80,000 feet: 250 250 At 300,000 feet: 500 500 Environmental characteristics: Temperature range: -70C to +125C. Maximum altitude

36、 rating: 300,000 feet. Acceleration: Applicable (15 gs maximum). Shock (specified pulse): Applicable, MIL-STD-202, method 213, test condition C, 200 gs for 6 1 ms, except horizontal flange mount peak g value shall be 100 gs for 6 1 ms. Contact chatter shall not exceed 10 microseconds maximum for clo

37、sed contacts and 1 microsecond maximum closure for open contacts. Vibration (sinusoidal): Applicable, MIL-STD-202, method 204, 30 gs, except frequency range shall be 70 to 3,000 Hz. Horizontal flange shall be 20 gs, 57 to 3,000 Hz. Contact chatter shall not exceed 10 microseconds maximum for closed

38、contacts and 1 microsecond maximum closure for open contacts. Vibration (random): Applicable to qualification and group C inspection. Test in accordance with MIL-STD-202, method 214, test condition IG (0.4 g2/Hz, 50 to 2,000 Hz), 15 minutes each plane, for horizontal flange mount test condition IE (

39、0.2 g2/Hz). Contact chatter shall not exceed 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts. Physical data: Dimensions and configurations: See figure 1. Weight: .058 pound (26.4 gs). Terminal strength: Solder hook terminals: Pull force: 5 pounds 0.5 p

40、ound. Bend: Applicable. Twist: Not applicable. Solder pin terminals: Pull force: For .040 diameter terminals: 5 pounds 0.5 pound. 2/ Dielectric may be improved by suitable insulation of terminals and wiring after installation. Provided by IHSNot for ResaleNo reproduction or networking permitted with

41、out license from IHS-,-,-MIL-PRF-83536/5C 11 Bend: Applicable. Twist: Not applicable. Socket pin terminals: Pull force: For .040 diameter terminals: 5 pounds 0.5 pound. Bend: Applicable. Twist: Not applicable. Terminal solderability: Applicable to solder pin and solder hook terminals only. Seal: Her

42、metic. Marking: Applicable. Part or Identifying Number (PIN): M83536/5 (dash number from table III and suffix letter designating failure rate level). Qualification inspection: Qualification inspection and sample size: See table IV. TABLE IV. Qualification inspection and sample size. 1/ Single submis

43、sion Group submission 18 units plus 1 open unit for level L at C = 0 2/ M83536/5-022 18 units plus 1 open unit for level L at C = 0 2/ 33 units plus 1 open unit for level M at C = 0 2/ M83536/5-022 33 units plus 1 open unit for level M at C = 0 2/ Qualification inspection as applicable M83536/5-022

44、Qualification inspection as applicable M83536/5-018 2 units, qualification inspection M83536/5-023 table, group II, shock, vibration, acceleration, terminal strength, and seal M83536/5-002 2 units, qualification inspection M83536/5-014 table, group II M83536/5-0311/ For retention of qualification or

45、 extension of qualification to lower failure rate levels, all life test data accumulated on MIL-PRF-83536/6 may be used in addition to MIL-PRF-83536/5 data. Prior to performance of retention of qualification testing, the relay manufacturer shall preselect the sampling plan. 2/ The number of units re

46、quired for qualification testing shall be increased as required in Q5, table II of MIL-PRF-83536, if the contractor elects to test the number of units permitting one or more failures. Prior to performance of qualification testing, the relay manufacturer shall preselect the sampling plan. Provided by

47、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 12 Qualification inspection (reduced testing) (sample size - 2 units each coil voltage and 1 unsealed unit). See table V. If the relays produced for MIL-PRF-83536/5 are similar in construction and

48、 design except for the suppression network to the relays produced for MIL-PRF-83536/6, then reduced testing for qualification of MIL-PRF-83536/5 relays may be performed concurrent with or subsequent to successful qualification of MIL-PRF-83536/6 relays. For reduced testing, see table V. TABLE V. Qualification inspection (reduced testing). Inspection 2 units each coil voltage Group II of qualification inspection table 1 unsealed sample unit for internal inspecti