1、MIL-S-13119E 2 July 1984 SUPERSEDING MIL-S-13119D (ME) 22 July 1975 . MIL LTARY SPEC IF KAT ION SPREADER, SLING: PLATE-TYPE , NONADJUSTABLE This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a nonadjustab

2、le, plate type, sling spreader. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. Unless otherwise specified the follow- ing specifications and standards of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DoDISS)

3、specified in the solicitation, form a part of this specification to the extent specified her e in. SPEC IF ICAT IONS FEDERAL QQ-S- 7 a 1 PPP-B-601 PPP-B-621 - Strapping, Steel and Seals. - Boxes, Wood, Cleated-Plywood. - Box, Wood, Mailed and Lock-Corner. Beneficial comments (recorrunendations, addi

4、tions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: USA Belvoir Research and Development Center, ATTN: STRBE-DS, Fort Belvoir, VA 22060 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at th

5、e end of this document or by letter. FSC 3940 THIS DOCUMENT CONTAINS 8 PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MILITARY MIL-T-7 04 MIL-W-86 11 p1 IL-P- 15 O2 4 / 6 MIL-G-2 024 1 M IL-S-8 17 3 3 STANDARDS FEDERAL FED-STD-595 MILITARY MIL

6、-STD-105 MIL-STD-129 MIL-STD- 130 MIL-STD-889 Treatment and Painting of Material. WeLding, Metal Arc and Gas, Steels, and 1 Corrosion and Heat Resistant Alloys; Process tor. Plates, Identification, Equipment. Gasket Material, Wool Felt, Impregnated, Adhesive, Pressure-Sensit ive. Sealing and Coating

7、 Compound, Corrosion Inh ib it ive. Colors. - Sampling Procedures and Tables for - Marking for Shipment and Storage. - Identification Marking of US Military - Dissimilar Metals. Inspection by Attributes. Property. (Copies of specifications and standards required by contractors in connection with spe

8、cific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.) 2.2 Other publications. The following documents form a part of this specifi- cation to the extent specified herein. indicated as DoD adopted shall be the issue listed in the curre

9、nt DoDISS and the supplement thereto, if applicable. The issues of the documents which are AMERICAN NATIONAL STANDARDS INSTITUT5 (ANSI) ANSI/AWS A2.4 - Symbols or Welding and Nondestructive Testing. B46.1 - Surface Texture. (Application for copies should be addressed to the American National Standar

10、ds Institute, Inc., 1430 Broadway, New York, NY 10018.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) A 36 - Structural Steel. D 3951 - Standard Practice for Commercial Packaging. (Application for

11、 copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) (Industry association specifications and standards are generally available for reference from libraries. and using Federal agencies.) They are also distributed among technical gr

12、oups 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specifi- cation shall take precedence. 3. RFiQUIREmNTS 3.1 Description. The sling spreader shall be as shown in figure 1 and as specified herein. 3.2 Firs

13、t article. When specified (see 6.21, a sample shall be subjected to first article inspection (see 4.3 and 6.3). 3.3 Material. Material shall be as specified herein. Materials not speci- fied shall be selected by the contractor and shall be subject to all provisions of this specification. All materia

14、l shall be new and unused. 3.3.1 Material deterioration and control. The sling spreader shall be fabricated from compatible materials, inherently corrosion and deterioration resistant or treated to provide protection against the various forms of corrosion and deterioration that may be encountered in

15、 any of the applicable storage and operating environment to which the item may be exposed. 3.3.1.1 Dissimilar metals. Dissimilar metals, as defined in MIL-STD-889, shall be electrically insulated from one another to minimize or prevent galvanic corrosion. corrosion inhibiting sealant conforming to M

16、IL-S-81733 or chromate tape con- forming to MIL-G-20241. Protection against any galvanic corrosion could also be obtained by exclusion of the electrolyte if feasible. Insulation may be provided by an insulating barrier such as a 3.3.1.2 Identification of materials and finishes. The contractor shall

17、identify the specific material, material finish or treatment for use with com- ponents and sub-components, and shall make information available, upon request, to the contracting officer or designated representative. 3.4 Steel. Steel used in the fabrication of the sling spreader shall con- form to AS

18、TM A 36. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.5 Plate surface. The sling spreader plate surface shall not deviate All edges shall not deviate ram a straight line by more from a straight edge (when placed against the surface of the spre

19、ader) by noTe than 1/8 inch. than 1J200 of its length. 3.6 Surface and edge finish. Plate finish shall be in the natural rolled Edge finish shall be as specified condition as received from the steel mill. in figure 1 and in accordance with ANSI B46.1. 3.7 Welding. Welding shall be in accordance with

20、 MIL-W-8611. Interpretation of welding symbols in figure 1 shall be in accordance with ANSI/AWS A2.4. 3.8 Cleaning and painting. The sling spreader shall be cleaned, treated, and painted in accordance with MIL-T-704, type A. The color of the finish paint shall mtch color No. 34087 of FED-STbi595. 3.

21、9 Identification marking. The sling spreader shall be identified in accordance with MIL-STD-130. m a plate 6 inches long by 3-1/2 inches wide conforming to MIL-P-15024/6. In addition, “TOTAL SWL 15,000 LB“ shall be legibly stamped on each plate. plate shall be attached to the spreader in the area sh

22、own in figure 1. The marking shall be applied to the sling spreader The 3.10 Workmanship. The finished sling spreader shall be free from dents, cracks, splits, and burrs. 4. QUALMY ASSURANCE PROVISIONS 4.1 Responsibility or inspection. Unless otherwise specified in the con- tract or purchase order,

23、the contractor ic responsible for the performance of all inspection requirements specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unl

24、ess disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such in- spections are deemed necessary to assure supplies and services conform to pre- scribed requirements. 4.1.1 Components and material inspection. The cont

25、ractor is responsible for insuring that components and materials used are manufactured, examined, and tested in accordance with referenced specifications and standards. 4.2 Classification of inspections. The inspection requirements specified herein are classified as follows: a. b. c. First article i

26、nspection (see 4.3). Quality conformance inspection (see 4.4). Inspection of packaging (see 4.6). 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4.3 First article inspection. 4.3.1 Examination. The sling spreader shall be examined as specified in

27、4.5.1. Presence of one or more defects shall be cause for rejection. 4.4 Quality conformance insmction. 4.4.1 Sampling. Sampling for examination shall be in accordance with MIL-STD-105. 4.4.2 Examination. Samples selected in accordance with 4.4.1 shall be examined as specified in 4.5.1. defects and

28、6.5 percent defective for minor defects. AQL shall be 2.5 percent defective for major 4.5 Inspec tion procedure. 4.5.1 Examination. The sling spreaders shall be examined as specified herein, for the following defects: Major 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. Dimensions and tolerances

29、not as specified. Material not as specified. Materials are not resistant to corrosion and deterioration or treated to be resistant to corrosion and deterioration for the applicable storage and operating environment. Dissimilar metals as defined in MIL-STD-889 are not effectively insulated from each

30、other. Contractor does not have documentation available for identif i- cation of material, material finishes or treatments. Welding not as specified. Straightness of plate surface or edges not as specified. Holes mispositioned or improper size. Painting not as specified. Workmanship not as specified

31、. Hinor 201. Identification marking not as specified or illegible. 202. Surface or edges not finished as specified. 203. Edges or plate have sharp corners or burrs. 4.6 Inspection of packaging. 4.6.1 Quality conformance inspection of pack. 4.6.1.1 Unit of product. For the purpose of inspection, a co

32、mpleted pack prepared for shipment shall be considered a unit of product. 5 c _. .- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4.6.1.2 Sampling. Sampling for examination shall be in .accordance with MIL-SID-105. 4.6.1.3 Examination. Samples sele

33、cted in accordance with 4.6.1.2 shall be examined for the following defects. AQL shall be 2.5 percent defective. 111. Boxes not as specified for level A or B. 112. Quantities packed together exceed the box limitations for level 113. Strapping not as specified for level A. 114. Packing not in accorda

34、nce with the referenced document as 115. Marking missing, illegible, incorrect, or incomplete for A or B. specified for commercial. level A, B, or commercial. 5. PACKAGING 5.1 Packin . Packing shall be level A, level B, or commercial as specified (see 6.2 + 5.1.1 Level A. The spreaders shall be pack

35、ed together in close fitting boxes conforming to PPP-Ei-601, overseas type, style optional or PPP-B-621, class 2, style optional, in quantities not to exceed the weight limitation of the box. The spreaders shall be blocked and braced within the box in a manner to prevent moveatent. Box closure and s

36、trapping shall be in accordance with - - the appendix to the applicable box specification. Strapping shall conform to QQ-S-781, class 1, type I or IV, size as applicable. Unless otherwise speci- fied (see 6.2) strapping shall be finish B. When specified (see 6.2) strapping shall be finish A. 5.1.2 L

37、evel B. The spreaders shall be packed as specified in 5.1.1 for level A except the boxes shall be domestic type or class as applicable. closure and strapping shall be in accordance with the appendix to the applicable box specification. Box 5.1.3 Commercial. The spreaders shall be packed in accordanc

38、e with !: ASTM D 3951. 5.2 Marking. 5.2.1 Military. Marking for military levels of protection (level A or B) shall be in accordance with MIL-STD-129. 5.2.2 Comercial. Marking for commercial packaging shall be in accordance with ASTM D 3951. 6 Provided by IHSNot for ResaleNo reproduction or networkin

39、g permitted without license from IHS-,-,-6. NOTES 6.1 Intended use. The sling spreader is intended for use as a component of a multiple barrel sling used for loading and unloading drums and barrels in quantities up to 10 in a single lift (see MIL-S-58040). 6.2 Ordering data. Acquisition documents sh

40、ould specify the following: a. Title, number, and date of this specification. b. When a first article is required for inspection and approval and the number of units required (see 3.2). c. Degree of packing required (see 5.1). d. When other than finish B strapping is required (see 5.1.1). 6.3 First

41、article. When a first article inspection is required, the item shall be tested and should be a preproduction sling spreader. article should consist of one or more units. include specific instructions in acquisition documents regarding arrangements for examinations, test, and approval of the first ar

42、ticle. The first The contracting officer should Custodians: Am - ME Air Force - 99 Pre par ing ac t iv i ty : Am - ME Project 3940-017 1 Review activity: Air Force - 84 DLA - IS 7 ri -.+., e?.*;- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-XIL-5- 13 119E rt U.S. GOVERNUENT PRIHTING OFFICE 1984-705-040/A3415 u) W l- O 2 v) W I u z z W U u) 2 u) z W I n - - a 0 - -1 -1 U W + O z W u) n -1-1 o 3l- W u z U W -I O I- -I -I a fl +I +I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-