1、 AMSC N/A FSC 5935 INCH-POUND W-C-596/126C 20 January 2012 SUPERSEDING W-C-596/126B 8 August 2001 FEDERAL SPECIFICATION SHEET CONNECTOR, PLUG, ELECTRICAL, SPECIAL PURPOSE, CABLE OUTLET, LOCKING, GROUNDING, 3 POLE, 4 WIRE, 20 AMPERES, 125/250 VOLTS, 50/60 HERTZ, 3-PHASE This specification is approved

2、 for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and W-C-596. Inches mm 0.967 24.56 1.980 50.29 2.350 59.69 4.300 109.22 NOTES: 1. Dimensions are in inches. 2. Metric equivalen

3、ts are given for information only. 3. Undimensioned pictorials are for reference purposes only. FIGURE 1. Configuration and dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-596/126C 2 REQUIREMENTS: Design and configuration: See figure

4、1. Dimensions: Shall conform to NEMA WD 6, configuration L15-20R. Armored construction: Not acceptable. Ratings: Voltage: 250 volts. Current: 20 amperes. Frequency: 50/60 hertz, 3-phase. Mating connector: W-C-596/125 and W-C-596/127. Strain relief: Accommodate cable diameter .465 - .710 inch. Part o

5、r Identifying Number (PIN): The PIN consists of the prefix W-C, the basic specification number, the specification sheet number, and the style number. W-C- 596 /126 -1 Style number (see table I) Specification sheet number Specification number W-C Prefix Supersession and cross reference: See table II.

6、 TABLE I. Dash number. Dash no. Supersedes style Description 1 Cable outlet TABLE II. Supersession and cross reference. 1/ Active Government PIN Superseded numbers CAGE 74545 CAGE 04009 CAGE 81091 W-C-596/126-1 2423 24CM23 6423 6424 L1520-C 1/ CAGE is the Commercial and Government Entity code which

7、is assigned and maintained by Defense Logistics Information Service (DLIS) in Battle Creek, MI. Changes from previous issue. Marginal notations are not used in the revision to identify changes with respect to the previous issue due to the extensiveness of the changes. Referenced documents. In additi

8、on to W-C-596, this document references the following: W-C-596/125 W-C-596/127 NEMA WD 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-596/126C 3 MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITIES: Custodians: DCGOVT - DCG Army - CR DOT -

9、 ACO Navy - YD GSA - 7FXE Air Force - 85 HHS FEC DLA - CC USDA - AFS Review activities: Preparing activity: Army - AV, CR4, MI DLA - CC Navy - AS, EC, MC, SH Air Force - 99 (Project 5935-2012-113) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 42600-7-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 7 Voltage Transformers U to 12 kV - Small design main dimensions indoor type《50Hz Um为0 72 kV至52 kV的仪表用变.pdf DIN 42600-7-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 7 Voltage Transformers U to 12 kV - Small design main dimensions indoor type《50Hz Um为0 72 kV至52 kV的仪表用变.pdf
  • DIN 42600-8-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV -Part 8 Current Transformers (support-type-insulators) U = 12 kV and U = 24 kV - Narrow design main dimensions.pdf DIN 42600-8-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV -Part 8 Current Transformers (support-type-insulators) U = 12 kV and U = 24 kV - Narrow design main dimensions.pdf
  • DIN 42600-9-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 9 Voltage Transformers U = 12 kV and U = 24 kV - Narrow design main dimensions indoor type《50 Hz U 0 72.pdf DIN 42600-9-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 9 Voltage Transformers U = 12 kV and U = 24 kV - Narrow design main dimensions indoor type《50 Hz U 0 72.pdf
  • DIN 42601 Berichtigung 1-2004 Corrigenda to DIN 42601 2003-09《对DIN 42601-2003的勘误》.pdf DIN 42601 Berichtigung 1-2004 Corrigenda to DIN 42601 2003-09《对DIN 42601-2003的勘误》.pdf
  • DIN 42601-2003 Instrument transformers for 50 Hz U of 72 5 kV and above - Basic requirements《50Hz、Um为72 5kV及以上的仪表用互感器 基本要求》.pdf DIN 42601-2003 Instrument transformers for 50 Hz U of 72 5 kV and above - Basic requirements《50Hz、Um为72 5kV及以上的仪表用互感器 基本要求》.pdf
  • DIN 4261-1-2010 Small sewage treatment plants - Part 1 Plants for waste water pretreatment《小型污水处理厂 第1部分 污水预处理工厂》.pdf DIN 4261-1-2010 Small sewage treatment plants - Part 1 Plants for waste water pretreatment《小型污水处理厂 第1部分 污水预处理工厂》.pdf
  • DIN 4261-5-2012 Small sewage treatment plants - Part 5 Infiltration of aerobic biologically treated domestic wastewater《小型污水处理厂 第5部分 好氧生物处理生活污水所用的渗透膜》.pdf DIN 4261-5-2012 Small sewage treatment plants - Part 5 Infiltration of aerobic biologically treated domestic wastewater《小型污水处理厂 第5部分 好氧生物处理生活污水所用的渗透膜》.pdf
  • DIN 4262-1-2009 Pipes and fittings for subsoil drainage of trafficked areas and underground engineering - Part 1 Pipes fittings and their joints made from PVC-U PP and PE《交通区地下排水设施.pdf DIN 4262-1-2009 Pipes and fittings for subsoil drainage of trafficked areas and underground engineering - Part 1 Pipes fittings and their joints made from PVC-U PP and PE《交通区地下排水设施.pdf
  • DIN 4262-3-2010 Pipes and fittings for subsoil drainage of trafficked areas and underground engineering - Part 3 Pipes and fittings made from concrete and their joints《高速公路和土木工程用混凝.pdf DIN 4262-3-2010 Pipes and fittings for subsoil drainage of trafficked areas and underground engineering - Part 3 Pipes and fittings made from concrete and their joints《高速公路和土木工程用混凝.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1