ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf

上传人:孙刚 文档编号:703925 上传时间:2019-01-03 格式:PDF 页数:5 大小:215.52KB
下载 相关 举报
ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf_第1页
第1页 / 共5页
ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf_第2页
第2页 / 共5页
ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf_第3页
第3页 / 共5页
ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf_第4页
第4页 / 共5页
ECA 186-14E-1985 Passive Electronic Component Parts Test Method for Method 14 Panel Seal Test《无源电子元件测试 方法14 板的密封试验》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、EIA L8b-14E 85 3234b00 0028577 8 W - - ANSI/EIA-186-14EL1984 APPROVED NOVEMBER 21, 1984 EIA STANDARD I STANDARD TEST .METHOD FOR PASSIVE ELECTRONIC COMPONENT PARTS METHOD 14: PANEL SEAL TEST EIA- 186- 14E FEBRUARY 1985 Engneering Department ELECTRONIC INDUSTRIES ASSOCIATION EIA Lb-14E 85 m 3234600 0

2、028578 T m _.- NOTICE EIA Engineering ,Standards and Publications are designed to serve the public st :through ,eliminating misunderstandings between manufacturers and sers, facilitating interchangeability and improvement of products, and ,assistr;ig the aser in .selecting and obtaining with minimum

3、 delay the ,pr.oper produc his particular need. Existence of such Standards and Pub- ljcations shall n any respect .preclude any member or non-member of EIA fr.orn manufacturing or selling products not conforming to such Standards and 1 the existence ,of such Stand-ards and IPublications preclude y

4、,those other than EZA members, whether the standard is y or internationally. liblications are adopted by EIA .without regard to may involve patents on articles, materials, or .does not assume any liability to any patent owner, tjon whatever to parties adopting the Recom- r Publication. mi Recommende

5、d Standard is considered to have international s tan- d,ar ion Implicatidns, but the International Electrotechnical Commis- sion bas chosen go write this test procedure for each type of component. %ere is, therefore no valid comparison ,between this EIA Recommended Stqqdard gad the Iptesnational Ele

6、ctrotechnical Commission recommendation. Published by ELE.CTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006 Copyright 1985 ELECTRONIC INDUSTRIES ASSOCIATION AI1 rights reserved PRICE: $5.00 Printed in U,S,A. EIA lb-LVE 5 m 3234600 0028579 l m EIA-186-

7、14E , . Page 1 METHOD 14 PANEL SEAL TEST (From EIA Standards Proposal No. 1775,- formulated under the cognizance of EIA P-9 Committee on Test Methods and Procedures and the EIA P-5.9 Working Group on Non-Sensitive Pushbutton and Keyboard Switches.) INTRODUCTION This test method forms a part of the l

8、atest revision of EIA Recommended Standard EIA/RS-186, which contains test guidance, definitions and standard test conditions. 1.0 2*0 3.0 PURPOSE This test is intended to determine the effectiveness of panel seals on electronic components which are intended for mounting through holes in panels or e

9、nclosures. The panel seals are exposed to water under pressure and observed for leakage. APPARATUS 2.1 The test chamber shall have a component mounting hole cut out as specified by the component Detail Specification, shall be sealed sufficiently to withstand the specified test pressures without leak

10、age, and shall be capable of applying, regulating, maintaining and measuring the required pressure. Unless otherwise specified, tap water shall be used. Figure 1 is a diagrammatic representation of a suitable chamber, it is not meant to limit the design which is left to the discretion of the test la

11、boratory. PROCEDURE 3.1 Mounting Prior to mounting the component, all gaskets which can normally be replaced in service without disassembly of the component proper, shall be disassembled from the component and then reassembled to it. The component shall be mounted through the wall of the test chambe

12、r, as indicated in Figure 1, using its normal mounting means. . EIA L8b-L4E 85 m 3234b00 0028580 8 m ETA- 1.8 6- 14E Page 2 3.2 Initial Measurements Any measurements to be made prior to test shall be in accordance with the component Detail Specification. 3.3 Applied Pressure Unless otherwise specifi

13、ed, an air presssure difference, as specified below, shall be applied across each seal or simultaneously across a group of seals being tested. 10 t 0.5kPa (1.5 psi) 44.5 - .5ka (6.5 psi) 105 + 5kPa (15 psi) 350 f: 10ka (50 psi) The test shall be made while the component is in the static (unoperating

14、) condition unless otherwise specified in the component Detail specification. 3.4 With the component mounted in the chamber, the chamber shall be filled with water to a level of 152.4 + 50.-8 mm (6 - + 2 inches) above the component (see Figure-1). The internal chamber pressure shall then be graduall

15、y increased at an approximate rate of 7kPa (gage) per minute (one pound per square inch gage per minute) until the specified test pressure is attained. The specified test pressure shall be maintained for 30 minutes. During this 30 minute period, components with dynamic seals shall be actuated for 25

16、 cycles of operation and all components shall be observed for evidence of water leakage. An opening in the body of enclosed components shall be made to observe whether leakage has occurred inside the components. 3.5 Final Measurements Neasurements after the seal test shall b made as specified in the

17、 component Detail Specification. 4.0 SUMMARY The following details shall be specified in the individual component speciication: I EIA Lb-34E 5 W 3234600 0028583 T W EIA-18 6- 14. Page 3 4.1 Applied Pressure Unless otherwise specified, the applied pressure shall be 105 5 5ka (15 psi) . 4.2 Mechanical

18、 Actuation Method of actuation and number of cycles of operation if other than as specified in 3.4. 4.3 Initial and Final Measurements 4.4 Mounting Hole size for component mounting, and locking means required. 4.5 Test temperature if other than room temperature. AIR PRESSURE u 105 kPa (ispsi) COMPONENT UNDER TEST ACTUATING FIGURE 1. Seal Test Enclosure -