ECA 213-1958 Test Point Locations for Printed Wiring Assemblies《印制电路组件的测试点定位》.pdf

上传人:livefirmly316 文档编号:703954 上传时间:2019-01-03 格式:PDF 页数:4 大小:152.46KB
下载 相关 举报
ECA 213-1958 Test Point Locations for Printed Wiring Assemblies《印制电路组件的测试点定位》.pdf_第1页
第1页 / 共4页
ECA 213-1958 Test Point Locations for Printed Wiring Assemblies《印制电路组件的测试点定位》.pdf_第2页
第2页 / 共4页
ECA 213-1958 Test Point Locations for Printed Wiring Assemblies《印制电路组件的测试点定位》.pdf_第3页
第3页 / 共4页
ECA 213-1958 Test Point Locations for Printed Wiring Assemblies《印制电路组件的测试点定位》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、a Cu) iu 8 H Test Y Printed a u _ EIA 233 58 m 3234600 O063273 5 m r ElA STANDARD Point Locatism for RS-213 Wihg A8sembZe.a (Reaffirmed March 1972) September 1958 Engneerng Department ELECTRON IC INDUSTRIES ASSOCIATION NOTICE EIA engineering standards are designed to serve the public interest throug

2、h eliminating mis- understandings between manufacturers and purchasers, facilitating interchangeability and improve- ment of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such standards shall not in any re

3、spect pre- clude any member or non-member of EIA from manufacturing or selling products not conforming to such standards, nor shall the existence of such standards preclude their voluntary use by those other than EIA members whether the standard is to be used either domestically or internationally.

4、Recommended standards are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the recommended sta

5、ndards. Published by ELECTRON IC I N DUSTRI ES ASSOCIATI ON Engineering Department 2001 Eye Street, N.W., Washington, D. C. 20006 0 Electronic Industries Association 1966 Ali rights reserved Price $1.00 - I ?- Ir EIA 213 58 9 3234600 00b3273 i 9 RS-213 Page 1 TEST POINT LOCATIONS FOR PRINTED WIRING

6、ASSEMBLIES e (From Standards Proposal No. 5 70 Formulated under the Cognizance of EIA Working Group P- 7.6 on Printed Wiring Boards) 1. INTRODUCTION This standard establishes systems of preferred locations for test points on printed wiring assemblies. It is to serve as a guide in the coordination of

7、 equipment design and is to be used in the design of printed wiring boards, test connectors, and testing equipment. 2. SCOPE 2.1 All test points shall be compatible in ali respects with the latest issue of EIA Standard RS-188, Standard Dimensional System for Automation Requirements. 2.2 All test poi

8、nts shall be brought out to any three edges of the printed wiring board whenever possible. 2.3 There are two preferred test-point location systems, A and B. A third system, C, can be used when it is impractical to bring the test points to the edge of the board. 3. TEST-POINT SYSTEM A 3.1 For test-po

9、int system A, the preferred multiple of the basic 0.025” (.635 mm) module shall be 8. This spacing of 0.200” (5.08 mm) shall be used to form a coordinated grid of lines separated by 0.200” (5.08 mm). 3.2 Test points shall be located on, or near, any three edges of the printed wiring board and fall o

10、n the intersections of the lines of the 0.200” (5.08 mm) grid. 3.3 If the O. 100” (2.54 mm) grid system of EL4 Standard RS-188 is used for locating mounting holes for components, the lines of the 0.200” (5.08 mm) test point grid will coincide with alternate lines of this 0.100 (2.54 mm) grid. If the

11、 0.025” (2.54 mm) grid system of RS-188 is used for locating mounting holes for components, the lines of the 0.200” (5.08 mm) test point grid will coincide with every eighth line of this 0.025” (.635 mm) grid. I 4. TEST-POINT SYSTEM B 4.1 For test point system B, the preferred multiple of the basic

12、0.025” (.635 mm) module shall be 4. This spacing of 0.100 (2.54 mm) shall be used to form a coordinated grid of lines separated by O. 100” (2.54 mm). , os I EIA 213 58 m 3234b00 00b3274 O m RS-213 Page 2 o 4.2 Test points shall be located on or near any three edges of the printed wiring board and fa

13、ll on the intersections of the lines of the 0.100 (2.54 mm) grid. 4.3 If the O. 100” (2.54 mm) grid system of EIA Standard RS-188 is used for locating mounting holes for components, the lines of the test point grid will coincide with the lines of this 0.100 (2.54 mm) component mounting hole grid. If

14、 the 0.025” (.635 mm) grid system of RS-188 is used for locating mounting holes for components, the lines of the 0.100 (2.54 mm) test point grid will coincide with every fourth line of this 0.025” (.635 mm) grid. 5. TEST POINT SYSTEM C 5.1 When it is impractical to bring test points to the edges of

15、the printed wiring bohey shall be located on the intersections of the lines of a 0.100 (2.54 mm) grid system anywhere on the board. 5.2 If the 0.100 (2.54 mm) grid system of EIA Standard RS-188 is used for locating mounting holes for components, the lines of the test point grid system will coincide with the lines of this 0.100 (2.54 mm) component mounting hole grid. If the 0.025” (-635 mm) grid system of RS-188 is used for locating mounting holes for components, the lines of the 0.100 (2.54 mm) test point grid will coincide with every fourth line of this 0.025” (.635 mm) grid.

展开阅读全文
相关资源
猜你喜欢
  • DL T 5400-2016 Construction technique specifications for hydraulic structure sliding formwork《水工建筑物滑动模板施工技术规范》.pdf DL T 5400-2016 Construction technique specifications for hydraulic structure sliding formwork《水工建筑物滑动模板施工技术规范》.pdf
  • DL T 5401-2007 Instrument allocation guide for electrical test of hydropower plant《水力发电厂电气试验设备配置导则》.pdf DL T 5401-2007 Instrument allocation guide for electrical test of hydropower plant《水力发电厂电气试验设备配置导则》.pdf
  • DL T 5402-2007 Specification for environmental protection design of water conservancy and hydropower project《水电水利工程环境保护设计规范》.pdf DL T 5402-2007 Specification for environmental protection design of water conservancy and hydropower project《水电水利工程环境保护设计规范》.pdf
  • DL T 5403-2007 Specification for commissioning and quality acceptance and evaIuation of flue gas desulphurization for thermal power plant《火电厂烟气脱硫工程调整试运及质量验收评定规程》.pdf DL T 5403-2007 Specification for commissioning and quality acceptance and evaIuation of flue gas desulphurization for thermal power plant《火电厂烟气脱硫工程调整试运及质量验收评定规程》.pdf
  • DL T 5404-2007 Technical rule of electric power system engineering design for SDH optical fiber cable communication project《电力系统同步数字系列(SDH)光缆通信工程设计技术规定》.pdf DL T 5404-2007 Technical rule of electric power system engineering design for SDH optical fiber cable communication project《电力系统同步数字系列(SDH)光缆通信工程设计技术规定》.pdf
  • DL T 5405-2008 Code for content depth on preliminary design of urban power cables《城市电力电缆线路初步设计内容深度规程》.pdf DL T 5405-2008 Code for content depth on preliminary design of urban power cables《城市电力电缆线路初步设计内容深度规程》.pdf
  • DL T 5406-2010 Specification for chemical grouting construction nof hydraulic structures n《水工建筑物化学灌浆施工规范》.pdf DL T 5406-2010 Specification for chemical grouting construction nof hydraulic structures n《水工建筑物化学灌浆施工规范》.pdf
  • DL T 5407-2009 Construction specification of inclined shaft and vertical shaft for hydropower and water resources engineering 《水电水利工程斜井坚井施工规范》.pdf DL T 5407-2009 Construction specification of inclined shaft and vertical shaft for hydropower and water resources engineering 《水电水利工程斜井坚井施工规范》.pdf
  • DL T 5408-2009 Specifications for disposition erection and acceptance of 220 380V power surge protection in power plant and substation 《发电厂、变电站电子信息系统220 380V电源电涌保护配置、安装及验收规程》.pdf DL T 5408-2009 Specifications for disposition erection and acceptance of 220 380V power surge protection in power plant and substation 《发电厂、变电站电子信息系统220 380V电源电涌保护配置、安装及验收规程》.pdf