EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf

上传人:medalangle361 文档编号:715262 上传时间:2019-01-04 格式:PDF 页数:28 大小:1.92MB
下载 相关 举报
EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf_第1页
第1页 / 共28页
EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf_第2页
第2页 / 共28页
EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf_第3页
第3页 / 共28页
EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf_第4页
第4页 / 共28页
EN 15651-4-2017 en Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4 Sealants for pedestrian walkways《建筑物和行人专用区连接用非结构密封剂-第4部分 行人专用区用密封剂》.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、BS EN 15651-4:2017Sealants for non-structuraluse in joints in buildings andpedestrian walkwaysPart 4: Sealants for pedestrian walkwaysBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 15651-4:2017 BRITISH STANDARDNational forewordThis British Standard is the UK i

2、mplementation of EN 15651-4:2017. It supersedes BS EN 15651-4:2012 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/547, Sealants for building and construction.A list of organizations represented on this committee can be obtained on request to its sec

3、retary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 94208 2 ICS 91.100.50 Compliance with a British Standard can

4、not confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2017.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 15651-4:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISC

5、HE NORM EN 15651-4 February 2017 ICS 91.100.50 Supersedes EN 15651-4:2012English Version Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 4: Sealants for pedestrian walkways Mastics pour joints pour des usages non structuraux dans les constructions immobilires et

6、 pour chemins pitonniers - Partie 4 : Mastics pour chemins pitonniers Fugendichtstoffe fr nicht tragende Anwendungen in Gebuden und Fugngerwegen - Teil 4: Fugendichtstoffe fr Fugngerwege This European Standard was approved by CEN on 25 December 2016. CEN members are bound to comply with the CEN/CENE

7、LEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre o

8、r to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the off

9、icial versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands

10、, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All r

11、ights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15651-4:2017 EBS EN 15651-4:2017EN 15651-4:2017 (E) 2 Contents Page European foreword 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 6 4 Requirements . 6 4.1 Identification req

12、uirements . 6 4.1.1 Short description of the sealant. 6 4.1.2 Thermogravimetric test . 7 4.1.3 Density 7 4.1.4 Indentation hardness (Shore hardness). 7 4.2 Conditioning, test procedure and substrates . 7 4.2.1 General 7 4.2.2 Classification . 7 4.2.3 Test procedure . 9 4.3 Performance requirements a

13、nd test methods for non-structural sealants for pedestrian walkways . 10 4.3.1 General 10 4.3.2 Sealants in pedestrian walkways used in cold climates . 10 4.3.3 Resistance to flow for non-sagging sealants . 11 4.3.4 Sealants with self-levelling properties . 11 4.3.5 Tear resistance 11 4.4 Additional

14、 performance requirements for exterior applications . 13 4.4.1 General 13 4.4.2 Artificial weathering by UV-radiation . 13 4.5 Release of dangerous substances 14 4.6 Reaction to fire . 14 4.6.1 General 14 4.6.2 Mounting and fixing conditions for test samples 14 5 Durability . 16 6 Sampling . 16 7 As

15、sessment and verification of constancy of performance . 16 7.1 General 16 7.2 Product type determination . 16 7.3 Factory production control . 16 8 Marking and labelling . 16 Annex A (informative) Example on the frequency of tests for factory production control. 17 Annex B (normative) Determination

16、of the change of volume of self-levelling cold applied joint sealants 18 B.1 Principle . 18 B.2 Apparatus and materials 18 B.3 Preparation of test specimens 18 B.4 Test procedure . 18 BS EN 15651-4:2017EN 15651-4:2017 (E) 3 B.5 Calculation and expression of results . 19 B.5.1 Change in mass 19 B.5.2

17、 Change in volume 19 Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No.305/2011 20 ZA.1 Scope and relevant characteristics 20 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) 21 ZA.3 Assignment of AVCP tasks . 21 Bibliography . 24 BS E

18、N 15651-4:2017EN 15651-4:2017 (E) 4 European foreword This document (EN 15651-4:2017) has been prepared by Technical Committee CEN/TC 349 “Sealants for joints in building construction”, the secretariat of which is held by AFNOR. This document supersedes EN 15651-4:2012. This European Standard shall

19、be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2017, and conflicting national standards shall be withdrawn at the latest by November 2018. Attention is drawn to the possibility that some of the elements of this docume

20、nt may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports basic work requirement

21、s of EU Regulation. For relationship with EU Regulation, see informative Annex ZA, which is an integral part of this document. This document is one of the product European Standards within the framework series of EN 15651 on Sealants for non-structural use in joints in buildings and pedestrian walkw

22、ays, as follows: Part 1: Sealants for facade elements, Part 2: Sealants for glazing, Part 3: Sealants for sanitary joints, Part 4: Sealants for pedestrian walkways (this document), Part 5: Assessment and verification of constancy of performance, marking and labelling. The following significant techn

23、ical changes have been implemented in this new edition: Clause 4.1.3 and Clause 5 have been improved; Clause 4.5 has been modified; Clause 7 and Annex ZA have been changed in accordance with the regulation (EU) No.305/2011. According to the CEN/CENELEC Internal Regulations, the national standards or

24、ganizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembour

25、g, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 15651-4:2017EN 15651-4:2017 (E) 5 1 Scope This European Standard specifies definitions and requirements for cold applied non-structural elastic seala

26、nts used for movement joints in floors in building construction for interior and exterior use. Areas of application are: floor joints designed for pedestrian walkways, public areas, movement joints between concrete slabs, areas with pedestrian load, areas used with trolleys, walkable floors, balconi

27、es, terraces, warehouses. NOTE Provisions on assessment and verification of constancy of performance - AVCP (i.e. Product type determination and Factory Production Control) and marking of these products are given in EN 156515. Chemical containment, cold applied joint sealants for concrete pavements

28、to be used in roads, airfields and sewage treatment plants, perimeter seals and seals in wood floors are excluded. This European Standard does not apply to non-structural sealants in any of non-paste form, to those used in pedestrian walkways. 2 Normative references The following documents, in whole

29、 or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13238, Reaction to fire tests for bui

30、lding products - Conditioning procedures and general rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 14187-3, Cold applied joint sealants - Part 3: Test method for the de

31、termination of self-levelling properties EN 15651-5:2017, Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 5: Evaluation of conformity and marking EN ISO 291, Plastics - Standard atmospheres for conditioning and testing (ISO 291) EN ISO 868, Plastics and ebonite

32、- Determination of indentation hardness by means of a durometer (Shore hardness) (ISO 868) EN ISO 2811-1:2016, Paints and varnishes - Determination of density - Part 1: Pycnometer method (ISO 2811-1:2016) EN ISO 6927, Buildings and civil engineering works - Sealants - Vocabulary (ISO 6927) EN ISO 73

33、89, Building construction - Jointing products - Determination of elastic recovery of sealants (ISO 7389) EN ISO 7390, Building construction - Jointing products - Determination of resistance to flow of sealants (ISO 7390) EN ISO 8339, Building construction - Sealants - Determination of tensile proper

34、ties (Extension to break) (ISO 8339) EN ISO 8340, Building construction - Sealants - Determination of tensile properties at maintained extension (ISO 8340) BS EN 15651-4:2017EN 15651-4:2017 (E) 6 EN ISO 9047, Building construction - Jointing products - Determination of adhesion/cohesion properties o

35、f sealants at variable temperatures (ISO 9047) EN ISO 10563, Building construction - Sealants - Determination of change in mass and volume (ISO 10563) EN ISO 10590, Building construction - Sealants - Determination of tensile properties of sealants at maintained extension after immersion in water (IS

36、O 10590) EN ISO 11358 (all parts), Plastics Thermographimetry (TG) of polymers General principles (ISO 11358) EN ISO 11431, Building construction - Jointing products - Determination of adhesion/cohesion properties of sealants after exposure to heat, water and artificial light through glass (ISO 1143

37、1) EN ISO 11600:2003, Building construction - Jointing products - Classification and requirements for sealants (ISO 11600:2002) EN ISO 11925-2, Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test (ISO 11925-2) ISO 13640, Build

38、ing construction Jointing products Specifications for test substrates 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 6927 and the following apply. 3.1 reactive sealant mainly curing by chemical reaction, with significant increase of the molecular

39、 weight of the main polymer 3.2 cure irreversible transformation of a sealant from a liquid or paste-like state into a hardened or rubber-like solid state 3.3 uncured / wet state of a sealant prior to the above transformation 4 Requirements 4.1 Identification requirements 4.1.1 Short description of

40、the sealant The short description of the non-structural sealant for pedestrian walkways shall include brand name, type (general, chemical, family, one or multi-component e.g. one component Polyurethane sealant in different colours, etc.). The primer shall be stated for the substrate concerned, if re

41、levant (name, chemical type, etc.). BS EN 15651-4:2017EN 15651-4:2017 (E) 7 4.1.2 Thermogravimetric test The test shall be carried out in accordance with EN ISO 11358 on the uncured or wet sealant, between 35 C and 900 C, temperature slope 10 C/min, non-oxidative condition (e.g. nitrogen). A single

42、sample shall be used for this test. A single specimen may be tested and there shall be no significant difference between the reference curve and derivative (profile). In the case of a multi-component sealant, each component shall be evaluated (if relevant). 4.1.3 Density 4.1.3.1 Principal A pyknomet

43、er is filled with the product under test. The density is calculated from the mass of the product in the pyknometer and the known volume of the pyknometer. 4.1.3.2 Method A test temperature of (23,0 0,5) C shall be used and the test sample and pyknometer shall be conditioned to this temperature, and

44、it shall be ensured that the temperature variation does not exceed 0,5 C during testing. The determination of the density shall be in accordance with EN ISO 2811-1:2016 using a suitable 50 cm3calibrated pyknometer as described in EN ISO 2811-1:2016, 6.1.1. An alternative is the 50 cm3Hubbard pyknome

45、ter as described in ISO 3507. Measurements should be carried out on the uncured or wet sealant and in the case of a multi-component sealant, each component shall be evaluated. At least three samples shall be tested. The specific pyknometer used and the mean value, recorded to two decimal places, sha

46、ll be declared. The tolerance of the declared values shall be within 5 %. 4.1.4 Indentation hardness (Shore hardness) The determination of the indentation hardness shall be in accordance with EN ISO 868. The test shall be performed on the cured sealant. The exact conditions of test shall be defined

47、by the manufacturer (i.e. thickness, cure/drying times and temperature and relative humidity, specific Shore type (A, D), test time, temperature, etc.). At least three samples shall be tested and five measurements taken per sample. The mean value and tolerances of all measurements, recorded to the n

48、earest unit, shall be declared. 4.2 Conditioning, test procedure and substrates 4.2.1 General When determining the classification of a sealant according to the requirements of this standard, the same conditioning procedure shall be used in all relevant test methods (use only Method A or Method B). F

49、or each test method, three test specimens for each substrate shall be tested. The same batch of sealant (and primer, if used) shall be used in all tests. The same substrates (material and surface finish) shall be used in all tests. 4.2.2 Classification 4.2.2.1 General Classes for cold applied elastic sealants for movement joints in floors in building construction are referred to as type: PW (= pedestrian walkways); EXT (= exterior application) and INT (= interior application); BS EN 15651-4:2017EN 15651-4:2017 (E) 8 CC (= cold c