1、BSI Standards PublicationBS EN ISO 4064-4:2014Water meters for cold potablewater and hot waterPart 4: Non-metrological requirements notcovered in ISO 4064-1BS EN ISO 4064-4:2014Incorporating corrigendum November 2014BS EN ISO 4064-4:2014 BRITISH STANDARDNational forewordThis British Standard is the
2、UK implementation of EN ISO 4064-4:2014. Together with BS EN ISO 4064-1:2014 it supersedes BS EN 14154-1:2005+A2:2011, which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee CPI/30, Measurement of fluid flow in closed conduits, to Subcommittee CPI/30/7, Volum
3、e flow-rate methods.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2014.
4、 Published by BSI Standards Limited 2014ISBN 978 0 580 88481 8ICS 91.140.60Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2014.Amendments/corrigenda iss
5、ued since publicationDate Text affected30 November 2014 Implementation of CEN Correction Notice 20 August 2014: Supersession information updated in national and CEN forewordsEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 4064-4 June 2014 ICS 91.140.60 Supersedes EN 14154-1:2005+A2:2011Engl
6、ish Version Water meters for cold potable water and hot water - Part 4: Non-metrological requirements not covered in ISO 4064-1 (ISO 4064-4:2014) Compteurs deau potable froide et deau chaude - Partie 4: Exigences non mtrologiques non couvertes par lISO 4064-1 (ISO 4064-4:2014) Wasserzhler zum Messen
7、 von kaltem Trinkwasser und heiem Wasser - Teil 4: Nichtmetrologische Anforderungen, die nicht Gegenstand von ISO 4064-1 sind (ISO 4064-4:2014) This European Standard was approved by CEN on 21 September 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate t
8、he conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standar
9、d exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the nation
10、al standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slova
11、kia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means
12、 reserved worldwide for CEN national Members. Ref. No. EN ISO 4064-4:2014 EEN ISO 4064-4:2014 (E) 3 Foreword This document (EN ISO 4064-4:2014) has been prepared by Technical Committee ISO/TC 30 “Measurement of fluid flow in closed conduits” in collaboration with Technical Committee CEN/TC 92 “Water
13、 meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2014, and conflicting national standards shall be withdrawn at the latest by June 2017. A
14、ttention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14154-1:2005+A2:2011. This document has been prepared under
15、 a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, C
16、zech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United King
17、dom. Endorsement notice The text of ISO 4064-4:2014 has been approved by CEN as EN ISO 4064-4:2014 without any modification. BS EN ISO 4064-4:2014EN ISO 4064-4:2014 (E) 3 Foreword This document (EN ISO 4064-4:2014) has been prepared by Technical Committee ISO/TC 30 “Measurement of fluid flow in clos
18、ed conduits” in collaboration with Technical Committee CEN/TC 92 “Water meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2014, and conflict
19、ing national standards shall be withdrawn at the latest by December 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This documen
20、t supersedes EN 14154-1:2005+A2:2011, EN 14154-2:2005+A2:2011, EN 14154-3:2005+A2:2011. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
21、 Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
22、 Endorsement notice The text of ISO 4064-4:2014 has been approved by CEN as EN ISO 4064-4:2014 without any modification. BS EN ISO 4064-4:2014EN ISO 4064-4:2014 (E) 3 Foreword This document (EN ISO 4064-4:2014) has been prepared by Technical Committee ISO/TC 30 “Measurement of fluid flow in closed c
23、onduits” in collaboration with Technical Committee CEN/TC 92 “Water meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2014, and conflicting
24、national standards shall be ithdrawn at the latest by December 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document sup
25、ersedes EN 14154-1:2005+A2:2011, EN 14154-2:2005+A2:2011, EN 14154-3:2005+A2:2011. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Repu
26、blic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endo
27、rsement notice The text of ISO 4064-4:2014 has been approved by CEN as EN ISO 4064-4:2014 without any modification. ii BS EN ISO 4064-4:2014ISO 4064-4:2014(E) ISO 2014 All rights reserved iiiContents PageForeword iv1 Scope . 12 Normative references 13 Terms and definitions . 14 Technical characteris
28、tics . 24.1 In-line meters . 24.2 Concentric and cartridge meters and exchangeable metrological modules 4Annex A (informative) Concentric water meter manifold .10Annex B (normative) Connection interfaces Solutions for cartridge meters 13Annex C (informative) Examples of adaptors and converters .24Bi
29、bliography .26BS EN ISO 4064-4:2014ISO 4064-4:2014(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Ea
30、ch member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the Internatio
31、nal Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different
32、 types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2, www.iso.org/directives.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be h
33、eld responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received, www.iso.org/patents.Any trade name used in this document is information gi
34、ven for the convenience of users and does not constitute an endorsement.The committee responsible for this document is ISO/TC 30, Measurement of fluid flow in closed conduits, Subcommittee SC 7, Volume methods including water meters.ISO 4064 consists of the following parts, under the general title W
35、ater meters for cold potable water and hot water: Part 1: Metrological and technical requirements Part 2: Test methods Part 3: Test report format Part 4: Non-metrological requirements not covered in ISO 4064-1 Part 5: Installation requirementsiv ISO 2014 All rights reservedBS EN ISO 4064-4:2014INTER
36、NATIONAL STANDARD ISO 4064-4:2014(E)Water meters for cold potable water and hot water Part 4: Non-metrological requirements not covered in ISO 4064-11 ScopeThis part of ISO 4064 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, clos
37、ed conduit. These water meters incorporate devices which indicate the integrated volume.This part of ISO 4064 specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand:a) a maximum admissible pre
38、ssure (MAP) equal to at least 1 MPa1)0,6 MPa for meters for use with pipe nominal diameters (DNs) 500 mm;b) a maximum admissible temperature (MAT) for cold potable water meters of 30 C;c) a MAT for hot water meters of up to 180 C, depending on class.In addition to meters based on mechanical principl
39、es, this part of ISO 4064 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices
40、. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and a
41、re indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 2281, Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tole
42、rances and designationISO 4064-1|OIML R 49-1, Water meters for cold potable water and hot water Part 1: Metrological and technical requirementsISO 7005-2, Metallic flanges Part 2: Cast iron flangesISO 7005-3, Metallic flanges Part 3: Copper alloy and composite flanges3 Terms and definitionsFor the p
43、urposes of this document, the terms and definitions given in ISO 40641|OIML R 49-1 apply.NOTE Many of the definitions used in this part of ISO 4064 conform to ISO/IEC Guide 99:2007|OIML V 2-200:2012,1OIML V 1:2013,2and OIML D 11.31) 1 MPa = 10 bar ISO 2014 All rights reserved 1BS EN ISO 4064-4:2014I
44、SO 4064-4:2014(E)4 Technical characteristics4.1 In-line meters4.1.1 Meter size and overall dimensionsMeter size is characterized either by the thread size of the end connections or by the nominal size of the flange. For each meter size, there is a corresponding fixed set of overall dimensions. The d
45、imensions of the meter, as illustrated in Figure 1, shall be in accordance with Table 1.H1W1W2H2LaKeyW1, W2W1+ W2is the width of a cuboid within which the water meter can be containedH1, H2H1+ H2is the height of a cuboid within which the water meter can be containedL length of a cuboid within which
46、the water meter can be containedNOTE The cover is at right angles to its closed position. Dimensions H1, H2, W1and W2are maxima; L is a fixed value with specified tolerances.aPipe axis.Figure 1 Meter size and overall dimensions4.1.2 Threaded connectionPermissible values of dimensions a and b for thr
47、eaded connections are given in Table 1. Threads shall conform to ISO 2281. Figure 2 defines dimensions a and b.abFigure 2 Threaded connection4.1.3 Flanged connectionFlanged end connections shall conform to ISO 7005-2 and ISO 7005-3 for the maximum pressure corresponding to that of the water meter. D
48、imensions shall be as given in Table 1.2 ISO 2014 All rights reservedBS EN ISO 4064-4:2014ISO 4064-4:2014(E)The manufacturer shall provide a reasonable clearance behind the rear face of the flange to allow access for installation and removal.Table 1 Water meter dimensions for threaded and flanged co
49、nnectionsDimensions in millimetresDNasizeaminbminPreferred values of LbAlternative values of LbW1, W2H1H215 10c12c16580, 85, 100, 105, 110, 114, 115, 130, 134, 135, 145, 170, 175, 180, 190, 200, 22065 60 22020 12 14 190105, 110, 115, 130, 134, 135, 165, 175, 195, 200, 220, 22965 60 24025 12 16 260 110, 150, 175, 199, 200, 210, 225, 273 100 65 26032 13 18 260 110, 150, 175, 199, 200, 230, 270, 300, 321 110 70 28040 13 20 300 200, 220, 245, 260, 27