FORD ESF-M3L75-A-2003 EPOXY RESIN POTTING COMPOUND TO BE USED WITH FORD WSS-M99P1111-A 《灌封胶用环氧树脂 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:ideacase155 文档编号:746213 上传时间:2019-01-14 格式:PDF 页数:2 大小:57.82KB
下载 相关 举报
FORD ESF-M3L75-A-2003 EPOXY RESIN POTTING COMPOUND  TO BE USED WITH FORD WSS-M99P1111-A  《灌封胶用环氧树脂  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共2页
FORD ESF-M3L75-A-2003 EPOXY RESIN POTTING COMPOUND  TO BE USED WITH FORD WSS-M99P1111-A  《灌封胶用环氧树脂  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 06 30 Revised Para 3.0 inserted; Para 3.3, 3.4, 3.5, 3.6, 3.7, 4 deleted 1991 10 28 DF00E00107002080 Inactivated ESF-M3L75-B, Updated A L.P. Rumao 1979 04 12 CF4H-RD 57221331 Released (Was XF-M3L27) Printed copies are uncontrolled Copyrig

2、ht 2003, Ford Global Technologies, Inc. Page 1 of 2 EPOXY RESIN, POTTING COMPOUND ESF-M3L75-A 1. SCOPE The material defined by this specification is a two-part 100% reactive epoxy resin. 2. APPLICATION This specification was released originally for material used in conjunction with ESF-M96B67-A Sili

3、ca Sand, as a potting compound for the TWC feedback engine control. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 To be run on each lot of mate

4、rial. 3.1.1 Viscosity, Brookfield RVF (ASTM D 2393, # 2 spindle at 10 rpm) Resin 1500 2500 MPa.s Hardener 1400 2600 MPa.s Mixed 1400 2400 MPa.s 3.1.2 Specific Gravity 105-107 (ASTM D 792) 3.1.3 Gel Time at 120 C, min 15 25 (ASTM D 2471, 25 mm cube sample) 3.1.4 Hardness, Durometer A 40 50 (ASTM D 22

5、40, 15 s dwell) To be run for initial approval and as required by Quality Control. 3.2 To be run for initial approval and as required by Quality Control. 3.2.1 Water Absorption, max 1% (ASTM D 570, 24 h) 3.2.2 Weight Loss, max 0.5% (168 h at 120 C) 3.2.3 Dielectric Strength, min 100 kV/cm (ASTM D 14

6、9) ENGINEERING MATERIAL SPECIFICATIONESF-M3L75-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 2 5. GENERAL INFORMATION The information below is provided for clarification and assistance in meeting the requirements of this specification. 5.1 SHELF LIFE 6 months when stored at or below 25 C. 5.2 SALT SPRAY No effect after 1000 h (ASTM B 117) 5.3 DIELECTRIC CONSTANT 4.5 (ASTM D 150 at 1 MHz)

展开阅读全文
相关资源
猜你喜欢
  • EN 60601-1-3-2008 en Medical electrical equipment - Part 1-3 General requirements for basic safety and essential performance - Collateral Standard Radiation protection in diagnosti.pdf EN 60601-1-3-2008 en Medical electrical equipment - Part 1-3 General requirements for basic safety and essential performance - Collateral Standard Radiation protection in diagnosti.pdf
  • EN 60601-1-6-2010 en Medical electrical equipment - Part 1-6 General requirements for basic safety and essential performance - Collateral standard Usability (Incorporates Amendment.pdf EN 60601-1-6-2010 en Medical electrical equipment - Part 1-6 General requirements for basic safety and essential performance - Collateral standard Usability (Incorporates Amendment.pdf
  • EN 60601-1-8-2007 en Medical electrical equipment - Part 1-8 General requirements for basic safety and essential performance - Collateral Standard General requirements tests and gu.pdf EN 60601-1-8-2007 en Medical electrical equipment - Part 1-8 General requirements for basic safety and essential performance - Collateral Standard General requirements tests and gu.pdf
  • EN 60601-1-9-2008 en Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral Standard Requirements for environmentally .pdf EN 60601-1-9-2008 en Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral Standard Requirements for environmentally .pdf
  • EN 60601-2-1-1998 en Medical Electrical Equipment - Part 2-1 Particular Requirements for the Safety of Electron Accelerators in the Range of 1 MeV to 50 MeV (Incorporates Amendment.pdf EN 60601-2-1-1998 en Medical Electrical Equipment - Part 2-1 Particular Requirements for the Safety of Electron Accelerators in the Range of 1 MeV to 50 MeV (Incorporates Amendment.pdf
  • EN 60601-2-1-2015 en Medical electrical equipment - Part 2-1 Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 5.pdf EN 60601-2-1-2015 en Medical electrical equipment - Part 2-1 Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 5.pdf
  • EN 60601-2-10-2000 en Medical electrical equipment Part 2-10 Particular requirements for the safety of nerve and muscle stimulators (Incorporates Amendment A1 2001 Remains Current).pdf EN 60601-2-10-2000 en Medical electrical equipment Part 2-10 Particular requirements for the safety of nerve and muscle stimulators (Incorporates Amendment A1 2001 Remains Current).pdf
  • EN 60601-2-10-2015 en Medical electrical equipment - Part 2-10 Particular requirements for the basic safety and essential performance of nerve and muscle stimulators (Incorporates .pdf EN 60601-2-10-2015 en Medical electrical equipment - Part 2-10 Particular requirements for the basic safety and essential performance of nerve and muscle stimulators (Incorporates .pdf
  • EN 60601-2-11-1997 en Medical Electrical Equipment Part 2 Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Incorporates Amendment A1 2004 Remains Current)《医用.pdf EN 60601-2-11-1997 en Medical Electrical Equipment Part 2 Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Incorporates Amendment A1 2004 Remains Current)《医用.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1