FORD FLTM AK 115-01-2001 QUANTITATIVE ANALYSIS OF CHLORIDES IN CLEANERS《清洁剂中的氯化物的定量分析》.pdf

上传人:ideacase155 文档编号:746780 上传时间:2019-01-14 格式:PDF 页数:4 大小:27.14KB
下载 相关 举报
FORD FLTM AK 115-01-2001 QUANTITATIVE ANALYSIS OF CHLORIDES IN CLEANERS《清洁剂中的氯化物的定量分析》.pdf_第1页
第1页 / 共4页
FORD FLTM AK 115-01-2001 QUANTITATIVE ANALYSIS OF CHLORIDES IN CLEANERS《清洁剂中的氯化物的定量分析》.pdf_第2页
第2页 / 共4页
FORD FLTM AK 115-01-2001 QUANTITATIVE ANALYSIS OF CHLORIDES IN CLEANERS《清洁剂中的氯化物的定量分析》.pdf_第3页
第3页 / 共4页
FORD FLTM AK 115-01-2001 QUANTITATIVE ANALYSIS OF CHLORIDES IN CLEANERS《清洁剂中的氯化物的定量分析》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD AK 115-01 Date Action Revisions 2001 01 22 Revised Editorial no technical change A. Cockman 2000 03 23 Revised Editorial no technical change A. Cockman 1990 06 12 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. QUANTITATIVE ANAL

2、YSIS OF CHLORIDES IN CLEANERS Application This test method is used to determine the percent chlorides in cleaners. Apparatus Required Hot Plate Oven Mechanical convection: Must be capable of heating to 150 C as well as maintaining 105 +/- 2 C for 15 minutes. Bunsen or Meeker Burner Fritted Glass Cru

3、cible with a Glass Microfiber Filter A Gooch crucible may also be used. (Whatman No. 934-AH) Analytical Balance Precision +/- 0.1 mg Beaker 250 mL Watch Glass Suitable for 250 mL beaker Buret or Pipet Suction Flask The above apparatus is available from any reputable laboratory equipment supply house

4、. Materials Required Nitric Acid Concentrated, reagent grade. Caution: Corrosive FORD LABORATORY TEST METHOD AK 115-01 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Silver Nitrate Reagent grade Distilled or Deionized Water 20 micromhos/cm at 25 C maximum conductivity (ASTM D 1125) Solut

5、ions Required Nitric Acid Solution 1:1 Nitric Acid Solution 1 % concentration (1 mL per 99 mL of distilled water) Silver Nitrate Solution 10 % concentration Silver Nitrate Solution 0.05 g/L Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a contr

6、olled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure A. Gravimetric Method 1. Take a 0.5 or 1.0 g aliquot of the prepared 1 % solution of cleaner in a 250 mL beaker. 2. Dilut

7、e to 200 mL with distilled water. 3. Add 10.0 mL of 1:1 nitric acid and boil on hot plate for 15 minutes. (a) If nitrites are present, an excess of nitric acid must be used. (b) Boiling must also be used to drive off the fumes of NO2. (c) Cool solution after this boiling. This will eliminate loss of

8、 chloride due to a possible spattering. FORD LABORATORY TEST METHOD AK 115-01 Page 3 of 4 Copyright 2001, Ford Global Technologies, Inc. 4. Add 10 mL of 10 % silver nitrate solution to the beaker after step 3. Add the silver nitrate from a buret or pipet, drop by drop using the 10 mL, stirring the s

9、olution during the addition. Allow the precipitate to settle and add a few more drops of reagent (AgNO3) and continue the addition as long as a precipitate forms with the reagent. Usually you have added about 20 % in excess of the reagent. 5. Heat to boiling, covering the beaker with a watch glass.

10、6. If the solution is still cloudy, stir vigorously. This will cause the finely-divided sliver chloride to coagulate and settle out so that the solution will be clear. Avoid exposing the precipitate to strong light as this will cause the exposed surface to decompose into the subchloride and liberate

11、 chlorine. 7. Filtration: B. Fritted Glass Crucible Method (or Quartz) 1. Prepare a fritted glass crucible with a glass microfiber filter and wash thoroughly with 1 % nitric acid solution. 2. Dry the crucible with the filter in an over at 100 C, then heat gently over a free blue flame. Cool in desic

12、cator and weigh. 3. Wash the silver chloride, first by decantation, then transfer to the crucible which has been placed in position on a suction flask. Gentle suction is applied and the precipitate is washed free by repeated additions of the wash water containing the nitric acid. 4. Place the crucib

13、le in an oven for 15 minutes or more and dry at 105 C. Now heat to 130 150 C to expel water. Cool in a desiccator. 5. Weigh. The weight in excess of that due to the crucible is due to silver chloride. 6. Calculate percent chlorine from the weight of sample taken. Note: (a) The silver chloride may be

14、 removed from the crucible by adding a piece of zinc and dilute sulfuric acid to the residue. (b) AgCl is soluble in ammonium hydroxide solution. FORD LABORATORY TEST METHOD AK 115-01 Page 4 of 4 Copyright 2001, Ford Global Technologies, Inc. (c) Owing to the slight solubility of AgCl, it has been r

15、ecommended to wash first with water containing AgNO3 (0.05 g/L), then with 1 % solution of nitric acid and finally with pure distilled water. (d) If chloride content is below 0.5 %, volumetric analysis should be used. Factors to use for calculations: (1) Weight AgCl x .24737 x 100 = % Cl Weight sample (2) % Cl x 1.6485 = % NaCl (3) % Cl x 2.1029 = % KCl (4) % Cl x 1.5088 = % NH4 Cl Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
  • BS 4729-2005+A1-2016 Clay bricks of special shapes and sizes - Recommendations《特种形状和规格的粘土砖 建议》.pdf BS 4729-2005+A1-2016 Clay bricks of special shapes and sizes - Recommendations《特种形状和规格的粘土砖 建议》.pdf
  • BS 4732-1988 Specification for file structure and labelling of magnetic tape for information interchange《信息交换用磁带标记和文件结构规范》.pdf BS 4732-1988 Specification for file structure and labelling of magnetic tape for information interchange《信息交换用磁带标记和文件结构规范》.pdf
  • BS 4736-1985 Method for determination of dimensional changes of fabrics induced by cold-water immersion《冷水浸泡织物尺寸变化测定方法》.pdf BS 4736-1985 Method for determination of dimensional changes of fabrics induced by cold-water immersion《冷水浸泡织物尺寸变化测定方法》.pdf
  • BS 4737-3 0-1988 Intruder alarm systems - Specifications for components - General requirements《擅入者报警系统 第3部分 元部件规范 第0节 一般要求》.pdf BS 4737-3 0-1988 Intruder alarm systems - Specifications for components - General requirements《擅入者报警系统 第3部分 元部件规范 第0节 一般要求》.pdf
  • BS 4737-3 1-1977 Intruder alarm systems - Specifications for components - Continuous wiring《擅入者报警系统 第3部分 元部件规范 第1节 连续布线》.pdf BS 4737-3 1-1977 Intruder alarm systems - Specifications for components - Continuous wiring《擅入者报警系统 第3部分 元部件规范 第1节 连续布线》.pdf
  • BS 4737-3 10-1978 Intruder alarm systems - Specifications for components - Vibration detectors《 擅入者报警系统 第3部分 元部件规范 第10节 振动探测器》.pdf BS 4737-3 10-1978 Intruder alarm systems - Specifications for components - Vibration detectors《 擅入者报警系统 第3部分 元部件规范 第10节 振动探测器》.pdf
  • BS 4737-3 12-1978 Intruder alarm systems - Specifications for components - Beam interruption detectors《擅入者报警系统 第3部分 元部件规范 第12节 射束间断探测器》.pdf BS 4737-3 12-1978 Intruder alarm systems - Specifications for components - Beam interruption detectors《擅入者报警系统 第3部分 元部件规范 第12节 射束间断探测器》.pdf
  • BS 4737-3 13-1978 Intruder alarm systems - Specifications for components - Capacitive proximity detectors《擅入者报警系统 第3部分 元部件规范 第13节 电容式接近探测器》.pdf BS 4737-3 13-1978 Intruder alarm systems - Specifications for components - Capacitive proximity detectors《擅入者报警系统 第3部分 元部件规范 第13节 电容式接近探测器》.pdf
  • BS 4737-3 14-1986 Intruder alarm systems - Specifications for components - Specification for deliberately-operated devices《擅入者报警系统 第3部分 元部件规范 第14节 审慎操作装置规范》.pdf BS 4737-3 14-1986 Intruder alarm systems - Specifications for components - Specification for deliberately-operated devices《擅入者报警系统 第3部分 元部件规范 第14节 审慎操作装置规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1