1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2008 02 07 Activated R. Patel Printed copies are uncontrolled Copyright 2008, Ford Global Technologies, LLC Page 1 of 3 CABLE, PRIMARY LOW TENSION, 150 C WSS-M1L137-A 1. SCOPE The material defined by this specification is a low tension strande

2、d cable rated for 60 volts rms. The cable is similar to SAE J1128 Type HTS (heavy duty thermoset). The insulation will have a 150 C classification rating. 2. APPLICATION The material specified is to be used primarily for fusible links in automotive electrical harnesses. 3. REQUIREMENTS 3.1 STANDARD

3、REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.2 RESTRICTED MATERIAL REQUIREMENTS Substance restrictions imposed by law, regulations or Ford, apply to the materials addressed

4、by this document. The regulations are defined in Engineering Materials Specification WSS-M99P9999-A1. 3.3 CONDUCTOR 3.3.1 Unless otherwise specified on the component drawing, the individual strands of the conductor shall be bare or tin-coated copper (soft or annealed) conforming to, respectively, AS

5、TM B 3 or ASTM B 33, except strand dimensions. These dimensions shall be controlled to yield the cross-sectional area listed for the conductor of the finished cable per Table 1. Conductor area shall be determined by measuring individual strand diameters and calculating the sum of the individual stra

6、nd areas. As an alternate method, conductor area may also be determined in accordance with ASTM B 263. 3.3.2 The strands shall be bunched per ASTM B 174. The maximum lay length shall be as specified in ASTM B 174 Table 2, Column A. Conductor strand count shall comply with Table 1. Missing strands ar

7、e not allowed. 3.4 SEPARATOR A suitable barrier (optional) between the insulation and the copper conductor shall be used that will prevent any adverse or detrimental interaction from taking place between those two components. In either case, the insulation (and inner sheath, if used) shall strip rea

8、dily from the conductors, leaving them reasonably clean and in suitable condition for terminating. ENGINEERING MATERIAL SPECIFICATIONWSS-M1L137-A Printed copies are uncontrolled Copyright 2008, Ford Global Technologies, LLC Page 2 of 3 3.5 INSULATION 3.5.1 The insulation material shall be as specifi

9、ed by the customer. The color of the insulation shall be specified on the engineering drawing of the component utilizing this material. Base color codes shall correspond to SAE J1128. 3.5.2 Insulation thickness shall comply with the requirements of Table 2. 3.6 CABLE QUALITY (TESTS) The following te

10、sts: Dielectric Test, Cold Bend Test, Oil Absorption Test, and Pinch Test correspond to SAE J1128. Results of these tests shall comply with the requirements of SAE J1128, type HTS. The tests listed below shall be conducted in addition to the tests listed above. 3.6.1 Insulation Physical Properties T

11、est The physical property test shall be run according to SAE J1128 Type HTS except the temp for aging shall be 180C for 168 hours. 3.6.2 Short Circuit Test The short circuit test shall meet the requirements specified in SAE J156. 3.6.3 Flame Test Flame Test shall be conducted per SAE J1128, Section

12、6.6, except that the specimen shall be suspended vertically. TABLE 1 - CONDUCTOR CONSTRUCTION SAE Wire Size Number of Wires Table Avg. Strand Size Approx. Dia. Of Stranded Conductor Area of Conductor Minimum mm mm mm 20 19 0.151 0.96 0.508 18 16 0.248 1.15 0.760 16 19 0.275 1.38 1.120 14 19 0.353 1.

13、78 1.850 12 19 0.443 2.23 2.910 10 19 0.570 2.88 4.650 8 37 0.500 3.38 7.230 ENGINEERING MATERIAL SPECIFICATIONWSS-M1L137-A Printed copies are uncontrolled Copyright 2008, Ford Global Technologies, LLC Page 3 of 3 TABLE 2 - DIMENSIONAL REQUIREMENTS SAE Wire Size Insulation Thickness Nominal Minimum Maximum Diameter of Finished Cable mm mm mm 20 0.91 0.64 2.90 18 0.94 0.66 3.19 16 1.02 0.71 3.57 14 1.04 0.73 4.02 12 1.17 0.82 4.74 10 1.17 0.82 5.45 8 1.40 0.98 6.16 Average insulation thickness shall not be less than 90% of the nominal thickness.