NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf

上传人:fuellot230 文档编号:978461 上传时间:2019-03-13 格式:PDF 页数:5 大小:49.30KB
下载 相关 举报
NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf_第1页
第1页 / 共5页
NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf_第2页
第2页 / 共5页
NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf_第3页
第3页 / 共5页
NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf_第4页
第4页 / 共5页
NAVY MIL-DTL-16377 77 A-2008 FIXTURES LIGHTING EMERGENCY BALLAST FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP《照明设备固定装置 一只17W或20WT12或17WT8荧光灯具紧急镇流器》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 6250 INCH-POUND MIL-DTL-16377/77A(SH) 18 December 2008 SUPERSEDING MIL-DTL-16377/77(SH) 27 September 2004 DETAIL SPECIFICATION SHEET FIXTURES, LIGHTING; EMERGENCY BALLAST, FOR ONE 17- OR 20-WATT T12 OR 17-WATT T8 FLUORESCENT LAMP This specification is approved for use by the Naval Sea S

2、ystems Command and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-16377. All dimensions in inches. For tolerances, other than specified herein, see 3.

3、5.2 of MIL-DTL-16377. CONTACT ARRANGEMENT WIRE COLOR LABEL TYPE I 1 Red w/ White Stripe 2 White w/ Red Stripe 3 Red w/ White Stripe 4 No Connection 5 White w/ Red Stripe 6 Blue w/ White Stripe 2“ 7 No Connection 8 No Connection9 Blue BALLAST MIL-DTL-16377/77 NSN 6250-01-491-7039 120 VOLT, 60 HERTZ O

4、PERATES ONE 17- to 20-WATT T-12 OR 17-WATT T8 LAMP CONTAINS NICKEL-CADMIUM BATTERY PROPER DISPOSAL REQUIRED DATE OF MANUFACTURE _ MANUFACTURERS IDENTIFICATION OR TRADEMARK 10 White 4“ 11 No Connection 12 Green 13 Red 14 Yellow FIGURE 1. Emergency ballast with wiring harness. Provided by IHSNot for R

5、esaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/77A(SH) 2 REQUIREMENTS: DESIGN: Electrical rating: 17-20 watts, 120 volts, 60 hertz. Circuit design: Ballast circuit shall incorporate Thyristor devices for protection against high voltage spikes. Dimension and c

6、onfigurations: See figure 1. Assembly: The emergency ballast consists of a high temperature, rechargeable NI-CAD battery; battery charger; AC power sensing circuit; solid-state inverter; low voltage battery cutoff, wiring harness, and enclosure. UL approved ballast may be furnished if it conforms to

7、 the dimensions and requirements specified. Weight: 4-pound maximum. Performance characteristics: Input voltage 120 VAC10 percent. Emergency operating time 5.0 hours minimum. Full recharge time 20 hours. Hi-temp NI-CAD battery 24 watt hours at 55 C. Battery rated voltage 6.0 volts. Battery discharge

8、 current 0.8 amps. Battery charge current 0.2 amps. Charging component of AC line 0.04 amps. Charging power 4.0 watts. System power factor 0.9 minute. System harmonics 3 percent. Low voltage cutoff 4.0 volts. Lumen output at 0 hours 240 lumens. Lumen output at 5 hours 144 lumens. DESIGNATION AND MAR

9、KING: One Type I label, equipment identification, reference MIL-DTL-16377 figure 11, as specified in figure 1. EXAMINATIONS AND TESTS: Examinations and tests shall be as specified in MIL-DTL-16377 and the following: First article testing/inspection: See table II. Comparison inspection: See table II.

10、 Conformance inspection: See MIL-DTL-16377. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/77A(SH) 3 Inspection of product for delivery: Examination: See MIL-DTL-16377. Conformance test: See MIL-DTL-16377. Examination for preparation o

11、f delivery: See MIL-DTL-16377. GENERAL INFORMATION: Table I. Standard parts. Table II. First article tests. NOTES: 1. Ballast shall conform to marking requirements and color coding of leads as specified in the applicable paragraph of NEMA C82.1. 2. T8 Emergency Ballast Only - Installation circuit wi

12、ring shall incorporate a minimum ratio of eight 17-watt lamps and one emergency 17-watt lamp. The 8-to-1 ratio is required for meeting MIL-STD-1399-300 harmonic requirements. The 17-watt emergency ballast produces non-linear current that must be offset by the linear current from eight 17-watt lamp b

13、allasts connected to the same circuit. 3. Emergency fixtures may be designated as Navy Emergency Automatic Lighting System (NEALS). TABLE I. Standard part. Name Military p/n or specification National Stock Number (NSN) Remarks Emergency ballast, wiring harnesses and mating connector, 17- or 20-watt

14、T12 or 17-watt T8 fluorescent lamp M16377/77-001 6250-01-491-7039 Complete assembly: includes wiring harnesses and matting AMP #206043 connectors. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/77A(SH) 4 TABLE II. First article tests a

15、nd comparison inspection for ballast.1/Test Requirement Test method Remarks Examination 3.13 4.5 - Operation 3. 4.8.1 -Electromagnetic interference 3.6.14 4.8.16 - Electrical equipment interface testing requirements: MIL-STD-1399-300 MIL-STD-1399-300 MIL-STD-1399-300 2/, 3/ Dielectric withstanding v

16、oltage 3.6.15 4.8.2 4/ Insulation resistance 3.6.16 4.8.3 4/ Shock 3.5.12 4.8.7 4/ Vibration 3.5.13 4.8.8 4/ Dielectric withstanding voltage 3.6.15 4.8.2 4/ Insulation resistance 3.6.16 4.8.3 4/ Noise 3.5.14 4.8.9 - Performance a. Power output b. Lumen output c. System power factor d. Operating time

17、 5/ 6/ 7/ Battery discharge test 8/ 8/ - NOTES: 1/Requirements and test methods use MIL-DTL-16377. 2/If less, then 1 KVA exception not applicable for input waveform THD. 3/Solid state components shall be subject to 250 positive spikes and 250 negative spikes (500 total spikes), one spike per minute,

18、 using testing method identified in MIL-STD-1399-300. 4/Tests shall be performed in the order specified. 5/The performance of the ballast shall be in accordance with the requirements listed in the applicable paragraph of NEMA C82.2. 6/Test procedure for performance shall be in accordance with NEMA C

19、82.1. 7/Sample lot size for inspection shall consist of five ballast units. 8/Battery discharge test shall be performed for first article testing. Testing shall include the following: The storage battery shall be capable of supplying and maintaining the maximum total associated load for a period of

20、no less than 5 hours and no less than 87.5 percent rated battery voltage. To determine if the unit complies with this requirement, the battery is to be tested at 55 C with its associated charging equipment as follows: a. The battery shall be charged to the maximum rated battery voltage in a period o

21、f time to not exceed 24 hours. b. The charged battery shall then be connected to its maximum rated load and permitted to discharge for 5 hours. At the end of the discharge, the battery voltage shall be no less than 87.5 percent or the rated battery voltage or the illumination no less than 60 percent

22、 of initial illumination. c. At the end of the discharge period, the battery shall be charged for a period of time not to exceed 24 hours. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/77A(SH) 5 TABLE II. First article tests and compa

23、rison inspection for ballast. Continued. d. The battery shall be again discharged at maximum rated load for 3.33 hours, and the battery voltage shall be no less the 87.5 percent of the rated battery voltage or the illumination no less than 60 percent of initial illumination at the end of 3.33 hours.

24、 e. Following the discharge, the battery again shall be recharged to rated battery voltage in a time period not to exceed 24 hours. f. The battery then shall be discharged while connected to maximum rated load until “low voltage cutoff” engages. The minimum time for cutoff shall be no less than 5 ho

25、urs. g. At the end of the discharge time, the battery shall be recharged to rated battery voltage in a time period not to exceed 24 hours. h. Following recharging, the battery shall be discharged at rated load for 5 hours. At the end of the discharge, the battery voltage shall be no less than 87.5 p

26、ercent rated battery voltage or the illumination no less than 60 percent of initial illumination. CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue, due to the extent of the changes. Preparing Activity: Navy SH (Proje

27、ct 6250-2008-001) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-