1、- rn 97799306 0256542 5 MIL-T-81734D(AS) . 11 July 1977 . Sup ers eding 6 December 1974 MIL-T-81734C(AS) MILITARY SPECIFICATION TEST SET, AIRBORNEWEAPON CONTROL SYSTEM AN/ AWM-2 3 (V) This specification has been approved by the Naval Air Systems Command, Department of the Navy 1. SCOPE 1.2 Scope. Th
2、is specification covers the performance, design, and test requirements for the Airborne Weapon Control System Test Set AN/AWM-23(V) . 2. APPLICABLE DOCUMENTS 2.1 General. The following documents, of the issue specified in AS-4053, Applicable Document List for AWCS Test Set AN/AiVM-23(V), form a part
3、 of this specification to the extent specified herein. SPECIFICATIONS Mil it ary MIL-H-5606 Hydraulic Fluid, Petroleum Base, Aircraft, Missile, MI L-C- 1377 7 and Ordnance Cable, Special Purpose, Electrfcal, General Specifi- cation for MIL-E-17555 Electronic and Electrical Equipment, Accessories, an
4、d Repair Parts; Packaging and Packing of MIL-T-18303 Test Procedures, Preproduction, Acceptance, and Life for Aircraft Electronic Equipment, Format for MIL-N-18307 , - Nomenclature and Identification for Electronic Aero- nautical and Aeronautical Support Equipment including Ground Support Equipment
5、Beneficial comments (recommendations, additions, deletions) and any perti- nent data which may be of use in improving this document should be addressed to : Engineering Specifications and Standards Department (Code 93) Naval Air Engineering Center, Lakehurct, NJ 08733, by using self-addressed Standa
6、rdi- zation Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. - -1- FSC-4935 M Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NIL-T-81734D 47 7777706 0256C43 7 Hi MIL-T-81734D (AS) MIL-I-21200 MI L-P- 2
7、7407 MIL-S-46844 MIL-W-81044 MIL-S-81775 (AS) MI L-T-8 1776 (AS) MIL-T-81778 (AS) MI L-K-8 1-779 (AS) MIL-S-81780(AS) MIL-T-81781 (AS) MIL-T-81782(AS) Hydraulic System MX-9043( )/AWM-23(v) Test Station, Module 05-217( )/AWM-23(V) and Test Station, Loa Frequency 05-215( )/AMi-23(V) and Kit, Tool, Spe
8、cial TK-222( )/ OJ- 378 ( ) /Awl- 23 (V) OJ-379 ( ) /AWM-23 (V) . AWM- 23 (V) Special Handling Equipment Adapter, Handling Antenna MX-9046( )/AWM-23(V) and Adapter, Handling, Tactical Information Display Bar, Lifting, Antenna Adapter, Hoisting, Antenna MX-9691( )/AW-23(V) MX-9047( )/AWM-23(V) MX-904
9、8( )/AWM-23(V) ADU-371( )/E Test Set, Missile Auxiliaries TS3479( )/AWM-23(V) Test Station, Computer OJ-216( )/AWM-23(V) Test Station, Controls-Displays- Doppler Filter Target Simulator, Infrared Test Station; Radio hequency OJ-214( )/AWM-23(V) SM-650( ) /AwM-23(V) OJ-213( )/AwM-23(V) Cooler, Liquid
10、, Electronic Equipment HD-957( )/AWM-23(V)* Cable Assembly Set, Electrical, MATS, Special Purpose Stand, Fill-Drain, Coolant System MT-4730 ( 1 /AWM-23 (V) Test Set, Antenna, Boresight TS-3568( )/AWM-23(V) Test Set, Missile Interface TS - 3561 ( )/All.l.l Approval of nonstandard materials, parts and
11、 processes. Parts submitted and approved on any prior PHOENIX contract need not be resub- mitted nor reap Ripple: +1 V peakyto-peak (p-p); Transient: - +20 percent, steady state; Transient recovery: 2 seconds recovery to steady state -9- Provided by IHSNot for ResaleNo reproduction or networking per
12、mitted without license from IHS-,-,-MIL-T- 8 1734D (AS) b. 115/200 volts, alternating cur- 43 ki rent, (Vac) , at 400 Hertz (Hz) , . 3-phase, 4-wire, Type III c. 115 Vac, at 60 Hz, single phase, 9 kVA Type I (See 6.8) d. 115 Vac, 60 Hz, 3-phase, 3-wire, 16.5 kVA ungrounded, Type I e. 440 Vac, 60 Hz,
13、 3-phase, 3-wire 11 kVA ungrounded, Type I 3.2.2.2 Clean air. The test set shall operate with clean air having the following characteristics: a. Temperature . +12.8 0.8 Celsius (C) (+55 +5 Fahrenheit (F) - b. Humidity No free moisture and dew point below shop ambient temperature c. Particulate Dust
14、particles 50.microns: density O. 10 gram perpound of dry air 7 inches of water (static) at rated flow - contamination d. Inlet pressure - e. Flow rate - 225 pounds per minute total, - 75 pounds per minute per inlet port The test set shall operate with potable water 3.2.2.3 Potable water, having the
15、following characteristics: a. Temperature 5.6 to 10C (42 to 50F) 30 gpm upon demand b. Flow rate - c. Pressure 50 to 150 psig at rated flow 3.2.2.4 Liquid coolant. The test set shall operate with Coolanol 25 (Monsanto Chemical Co.), Oronite Flo-Cool 180 (Chevron Chemical Co.) or equivalent in accord
16、ance with HMS 20-1458. 3.2.2.5 Helium. The test set shall operate with helium, at pressures ranging from 1800 to 2200 psig and conforming to MIL-P-27407. 3.2.2.6 Nitrogen. The test set shall operate with nitrogen conforming to BB-N-411, Type I, Class I, Grade A, and supplied at pressures ranging fro
17、m 2800 to 3000 psig to a two stage regulator. Test stations shall be capable of using nitrogen supplied at 125 - + 12 psig from the two stage -regulator. - 10- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-81734D (AS) 3.2.2.7 Hydraulic fluid.
18、 The test set shall operate with hydraulic fluid conforming to MIL-H-5606. 3.2.3 Service conditions. 3.2.3.1 Electrical. The test set shall be designed to meet the perform- ance requirements of this specification when supplied with the electric,al power of 3.2.2.1. Commercial equipment items selecte
19、d as elements of the test set shall meet the electrical service requirements of the manufacturers specifications covering these items. 3.2.3.2 Environmental. The test set shall operate satisfactorily under the environmental service conditions specified below. 3.2.3.2.1 Organizational level. Equipmen
20、t designed for use at the organi- zational level of maintenance shall withstand exposure to the environments specified in MIL-T-21200 for.Class2 equipme%t, except that the maximum non-. operating temperature shall be.+.71 C (+159.8 F) and the vibration exposure shall be in accordance wth MILISTD-167
21、, Type I. 3.2.3.2.2 Intermediate level. Equipment designed for use at the inter- mediate level of maintenance shall meet the following environmental re- quirements : a. b. Vibration - The equipment shall withstand exposure to vibration in accordance with MIL-STD-167, Type I. Shock - The equipment sh
22、all withstand, with commercial equipment not installed in the test set, shock pulses of 15g amplitude for 11 + 1 milliseconds duration applied in accordance with MIL-Ty21200. Temperature/altitude - The test set shall provide con- tinuous, satisfgctory operatio: over temperatures ranging from zero to
23、 45 C (+32 to +113 F) at altitudes ranging from sea level to 10,OOOofeet. Tle maximum nonoperating tempergture shall be +71 C(+159.8 F), and the minimum shall be -40 C(-40 F). The maximum nonoperating altitude shall be 50,000 feet. Humidity - The test set shall withstand the effects of humidities up
24、 to 95 percent, with no condensation, under operating or nonoperating conditions. except commercial equipment, shall withstand the effects of humidities up to 95 percent, including condensation, under operating or nonoperating conditions. c. d. The test set, 3.2.4 Maintainability. MIL=T-21200, as mo
25、dified below, shall apply. 3.2.4:l Mean time to repair (MTTR). The test set items-of Table I shall be capable of being restored to normal operation within 4 hours (mean time) after a malfunction is detected (see 6.3.14). - 11- Provided by IHSNot for ResaleNo reproduction or networking permitted with
26、out license from IHS-,-,-MIL-T-81734D (AS) 3.2.4.2 Test points. Test points shall be in accordance with MIL-T-21200 except that color coding shall be in accordance with GS 30620-781. . 3.2.4.3 Shop replaceable assemblies (SRAS). The electronic portions of the test set shall be divided into SRAs. be
27、Quick Replaceable Assemblies (QRAs). All others shall be In-Place Repairable Assemblies (IPRAs). practicable use of microelectronic packages. Where practicable, these shall QRAs shall be designed to make maximum 3.2.4.4 Self test capabilities. Self test capability shall be as speci- fied in the appl
28、icable specifications. 3.2.5 Reliability. Mean time between failures (MTBF) for the items of Table I under full powered conditions shall be as specified in the appli- Lable specifications (see 6.3.13). 3:2.5.1 Operating life. The test set shall have a minimum of 15,000 hours operating life (see 6.3.
29、12) with scheduled maintenance and replace- ment of parts. 3.2.52 Storage life. Storage life of the test set shall be a minimum of 5 years. over a period of 16 hours, continuously or intermittently, without the , necessity for readjustment of any controls which are inaccessible during . normal use.
30、A standby condition shall be provided, as necessary, to main- . tain component temperature stability, 3.2.5.3 Operational stability. The test set shall operate satisfactorily - . 3.2.6, Electromagnetic interference CEML). EM1 for each intermediate maintenance level item of the test set shall be in a
31、ccordance with MIL-STD- 461, Class lD, except that tests CEO1, CE02, CE03, CE04, RSO1, RS02, and RS04 and limits thereof shall be as specified in the specification for each test set item listed in Table I of this specification. Each organization level equipment, except the Service Set, Hydraulic Sys
32、tem and the Special Handling Equipment, shall be in accordance with MIL-STD-461, Class lD, except the limits of test RS03 shall be in accordance with the test levels of Table II, and the tests CEO1, CE02, CE03, CE04, RSO1, RS02 and RS04 and limits shall be in accordance with the specification. for e
33、ach test set item listed in Table I of this specification. 3.2.7 Utilities protection. The test set shall protect itself and the item under test from damage as required for out-of-tolerance COOT) utility inputs as follows, 3.2.7.1 .Liquid cooling protection. Protection shall be provided for an OOT l
34、iquid coolant flow rate. temperature. T conditions exist. Protection shall also be provided for an OOT The protective devices shall be effective when either or both I -12- a Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE II ENVIRONMENTAL LEVEL
35、S (Unperturbed Field) Frequency . (MZ) Communications Equipment (Continuous wave, unmodu- lated carrier values) . .25 - .5 35 2 - 32 100 - 156 225 - 400 Radar Equipment Electric Field (vo 1 ts/meter) 300 100 FIELD INTENSITY Magnetic Field :Ampere turns/me t er) .5 c 200 - 225 400 - 450 1009 - 1300 2
36、700 - 3600 5400 - 5900 8500 - 10300 -13- Average Power Density Milliwatts/square centimeter . o1 . o1 10 1 1 10 100 100 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
37、se from IHS-,-,-MIL-T-L734D 47 = 7777706 0256556 5 MI L -T- 8 1 734D (AS) c. d. e. Program loading of computer non-destructive read-out (NDRO) Repair or replacement of malfunctioning items. Determination that repaired or replaced items are perform- ing within allowable limits. . and bulk store devic
38、es. 3.3.4 Warmup time. Narmup time for the test set shall not exceed 5 minutes for standard conditions of 4.4 and 20 minutes for the extreme temperature conditions of 3.2.3.2, test set to meetthe warmup requirements. Standby circuits may be used by the 3.4 Detailed functional requirements. Functiona
39、l requirements of the individual test set items shall be in accordance with the applicable _ specifications of Table I. 3.5 Workmanship. iYorkmanship shall conform to MIL-STD-454, Require- ment 9. 3.6 Elements. Elements requirements of the individual test set items shall be as specified in the appli
40、cable specifications of Table I. . 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the s
41、upplier may utilize his own facilities or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the inspections set forth in the specificationwhere such inspections are deemed necessary to assure supplies and services conform to prescribed requir
42、ements. 4.2 .General. Acceptance of the AN/AiW-23(V) shall be solely on the basis of this specification. 4.2.1 Classification. The AN/AiW-23(V)-shall be classified as a pro- duction model in accordance with MIL-STD-280: form of final production design made by production tools, jigs, fixture-s,_ and
43、methods. It employs standard parts (or nonstandard parts approved by the agency concerned).“ from the mandatory requirements (parts, processes, etc.) of the technical documents, a form DD 1694 shall be prepared. mitted to the Navy Technical Representative (NTR) for approval. Major and critical devia
44、tions and waivers shall be submitted to Naval Air Systems Command for approval in accordance with the contract. The DD Form 1694 (Request for Deviation/Waiver) shall be prepared as delineated in MIL-STD-480. “A model in its final,. If it is necessary to depart temporarily Minor deviations shall be s
45、ub- 4.2.2 -Individual items. Individual items of Table I of the AN/AivM-23(V) will be accepted separately and independently. -15- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-81734D(AS) . . c 4.2.3 In-process inspection. Prior to entering ac
46、ceptance tests, all AN/AWM-23(V) items shall have completed in-process inspections. 4.2,4 In-process data. The data resulting from contractor conducted in-process inspections shall be presented to the Cognizant Government Inspector (CGI) at the time items of the AN/AWM-23(V) are offered for Governme
47、nt inspection and acceptance. acceptance test plan for the individual item. test criteria and measurement results are a part of the acceptance proce- dure document for each item. 4.2.5 Acceptance test plan. Al1,testing shall be as specified in the Data sheets containing 4.2.6 Test results. The contr
48、actor shall present test data, as docu- mented evidence that each Test Station/Test Set has completed tests, as applicable. responsible contractor.test engineer and inspected by contractor Quality Assurance (QA). A record shall be kept of all failures. Test indications shall be recorded on test data
49、 sheets by.the 4.2.7 Acceptance. Upon completion of Government Inspection, Government acceptance will be consummated by CGI execution of the DD Form 250. 4.2.8 Utilities. Forced-air cooling, electrical power consumption, water, nitrogen, compressed air, and forced liquid cooling performance are facilities requirements and need not require verification as conditions . of acceptance. within the required