1、NFPA1071 Standard for Emergency Vehicle Technician Professional Qualifications 2016 Edition NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 An International Codes and Standards Organization 1/14ISBN: 978-145591013-7 (Print)ISBN: 978-145591020-5 (PDF)IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA
2、STANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDSNFPAcodes, standards, recommended practices, and guides (“NFPA Standards”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American Nationa
3、l Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on fire and other safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independentl
4、y test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards.The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or in
5、directly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information published herein.In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or oth
6、er services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determi
7、ning the exercise of reasonable care in any given circumstances.The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document.
8、Any certification or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the responsibility of the certifier or maker of the statement.REMINDER: UPDATING OF NFPA STANDARDSUsers of NFPA codes, standards, recommended practices, and g
9、uides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. An official NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interi
10、m Amendment and any Errata then in effect.In order to determine whether an NFPA Standard has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, visit the Document Information Pages on NFPAs website. The Document Information Pages provide up-to-date, document sp
11、ecific information including any issued Tentative Interim Amendments and Errata.To access the Document Information Page for a specific NFPA Standard, go to http:/www.nfpa.org/docinfo to choose from the list of NFPA Standards or use the search feature on the right to select the NFPA Standard number (
12、e.g., NFPA 101). In addition to posting all existing Tentative Interim Amendments and Errata, the Document Information Page also includes the option to sign-up for an “Alert” feature to receive an email notification when new updates and other information are posted regarding the document.1/14IMPORTA
13、NT NOTICES AND DISCLAIMERS CONCERNING NFPASTANDARDS ADDITIONAL NOTICES AND DISCLAIMERSUpdating of NFPA Standards Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that these documents may be superseded at any time by the issuance of new editions or
14、may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. An official NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendments and any Errata then in effect. In order to deter
15、mine whether a given document is the current edition and whether it has been amended through the issuance of Tentative Interim Amendments or corrected through the issuance of Errata, consult appropriate NFPA publications such as the National Fire CodesSubscription Service, visit the NFPA website at
16、www.nfpa.org, or contact the NFPA at the address listed below.Interpretations of NFPA StandardsA statement, written or oral, that is not processed in accordance with Section 6 of the Regulations Governing the Development of NFPA Standards shall not be considered the official position of NFPA or any
17、of its Committees and shall not be considered to be, nor be relied upon as, a Formal Interpretation.PatentsThe NFPA does not take any position with respect to the validity of any patent rights referenced in, related to, or asserted in connection with an NFPA Standard. The users of NFPA Standards bea
18、r the sole responsibility for determining the validity of any such patent rights, as well as the risk of infringement of such rights, and the NFPA disclaims liability for the infringement of any patent resulting from the use of or reliance on NFPA Standards.NFPA adheres to the policy of the American
19、 National Standards Institute (ANSI) regarding the inclusion of patents in American National Standards (“the ANSI Patent Policy”), and hereby gives the following notice pursuant to that policy:NOTICE: The users attention is called to the possibility that compliance with an NFPA Standard may require
20、use of an invention covered by patent rights. NFPA takes no position as to the validity of any such patent rights or as to whether such patent rights constitute or include essential patent claims under the ANSI Patent Policy. If, in connection with the ANSI Patent Policy, a patent holder has filed a
21、 statement of willingness to grant licenses under these rights on reasonable and nondiscriminatory terms and conditions to applicants desiring to obtain such a license, copies of such filed statements can be obtained, on request, from NFPA. For further information, contact the NFPA at the address li
22、sted below.Law and RegulationsUsers of NFPA Standards should consult applicable federal, state, and local laws and regulations. NFPA does not, by the publication of its codes, standards, recommended practices, and guides, intend to urge action that is not in compliance with applicable laws, and thes
23、e documents may not be construed as doing so.CopyrightsNFPA Standards are copyrighted. They are made available for a wide variety of both public and private uses. These include both use, by reference, in laws and regulations, and use in private self-regulation, standardization, and the promotion of
24、safe practices and methods. By making these documents available for use and adoption by public authorities and private users, the NFPA does not waive any rights in copyright to these documents.Use of NFPA Standards for regulatory purposes should be accomplished through adoption by reference. The ter
25、m “adoption by reference” means the citing of title, edition, and publishing information only. Any deletions, additions, and changes desired by the adopting authority should be noted separately in the adopting instrument. In order to assist NFPA in following the uses made of its documents, adopting
26、authorities are requested to notify the NFPA (Attention: Secretary, Standards Council) in writing of such use. For technical assistance and questions concerning adoption of NFPA Standards, contact NFPA at the address below.For Further InformationAll questions or other communications relating to NFPA
27、 Standards and all requests for information on NFPA procedures governing its codes and standards development process, including information on the procedures for requesting Formal Interpretations, for proposing Tentative Interim Amendments, and for proposing revisions to NFPA standards during regula
28、r revision cycles, should be sent to NFPA headquarters, addressed to the attention of the Secretary, Standards Council, NFPA, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101; email: stds_adminnfpa.orgFor more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes an
29、d standards can be viewed at no cost at www.nfpa.org/freeaccess.Copyright 2014 National Fire ProtectionAssociation.All Rights Reserved.NFPA1071Standard forEmergency Vehicle Technician Professional Qualifications2016 EditionThis edition of NFPA 1071, Standard for Emergency Vehicle Technician Professi
30、onal Qualifica-tions,waspreparedbytheTechnicalCommitteeonEmergencyVehicleMechanicTechniciansProfessionalQualificationsandreleasedbytheCorrelatingCommitteeonProfessionalQuali-fications. It was issued by the Standards Council on July 14, 2014, with an effective date of July29, 2014, and supersedes all
31、 previous editions.This edition of NFPA 1071 was approved as an American National Standard on July 29,2014.Origin and Development of NFPA 1071In July 1995, the Standards Council, after receipt of a request from the MaintenanceSection of the InternationalAssociation of Fire Chiefs for the development
32、 of a standard forthe professional qualifications of emergency vehicle technician, approved the establishmentofatechnicalcommitteeonEmergencyVehicleTechnicianProfessionalQualificationsunderthe Professional Qualifications project. The Committee developed the first edition ofNFPA 1071, Standard for Em
33、ergency Vehicle Technician Professional Qualifications, which estab-lished the minimum job performance requirements for a person qualified as an emergencyvehicle technician who is engaged in the inspection, diagnosis, maintenance, repair, andtesting of an emergency response vehicle.In the 2006 editi
34、on of the document, the Committee added a new chapter for EmergencyVehicle Technician III. The Committee also revised the document to comply with the newrequirements of the Manual of Style for NFPATechnical Committee Documents.The 2011 edition added a skills maintenance requirement for each level of
35、 EmergencyVehicle Technician (EVT). The Committee updated the EVT requirements to address tech-nological enhancements regarding new apparatus. The Technical Committee defined thedelineation between the three levels of EVT. Generally speaking, the EVT I is responsible foroperational checks, the EVT I
36、I is responsible for performance checks, and the EVT III isresponsible for supervision and managerial skills. The skills and knowledge requirements foreach level of EVT were updated and brought in line with NFPA 1901, Standard for AutomotiveFire Apparatus.The Technical Committee has revised several
37、areas of the document for the 2016 edition.A number of Manual of Style and formatting changes have been made to several job perfor-mance requirements (JPRs).Annex C, Qualifications and Certification, has been updated toreflect changes to programs such as the following: Automotive Service Excellence
38、(ASE);Emergency Vehicle Technicians (EVT) Certification Commission; and various Canadian pro-vincial journeyman license and registered apprentice programs. In addition, the TechnicalCommittee completed a job task analysis for emergency vehicle technicians.The Correlating Committee on Professional Qu
39、alifications is striving to standardize theprofessional qualifications documents. Chapter 1,Administration, andAnnex B, Explanationof the Professional Qualifications Standards and Concepts of JPRs, will be consistent for allprofessional qualifications documents.The Committee did not receive any comm
40、ents on the first draft revisions. As a result,NFPA1071 received early consent from the Standards Council. This does not change the editionyear for the document, but it does allow the document to be released earlier to the public.10711NFPAand National Fire ProtectionAssociation are registered tradem
41、arks of the National Fire ProtectionAssociation, Quincy, Massachusetts 02169.Correlating Committee on Professional Qualifications (PQU-AAC)William E. Peterson, ChairKissimmee, FL MRep. International Fire Service TrainingAssociationGregg A. Cleveland, La Crosse Fire Department, WI URep. NFPAFire Serv
42、ice SectionGordon Descutner, Alaska DPS Fire Standards Council,AK URep.Alaska Fire Standards CouncilDouglas P. Forsman, Fairfield Bay Fire Department,AR LScott M. Gorgon, North Las Vegas Fire Department,NV LRep. InternationalAssociation of Fire FightersR. Kirk Hankins, Fire Consulting or greater. 19
43、01, 20093.3.17 Low Voltage Circuit, Equipment, or System. An electri-cal circuit, equipment, or system where the voltage does notexceed 30 V rms (ac) or 42.4 V peak (dc), or 60 V dc; usually12 V dc in fire apparatus. 1901, 20093.3.18 Maintenance. The act of servicing an emergency re-sponse vehicle o
44、r a component in order to keep the vehicleand its components in proper operating condition.3.3.19 ManufacturersSpecifications. Anyrequirementorser-vice bulletin an emergency response vehicle builder or com-ponent producer provides with regard to the use, care, andmaintenance of its product(s).3.3.20
45、 Proper(ly). In accordance with the manufacturersspecifications or as recommended by the manufacturer.1911, 20123.3.21 Qualified Person. A person who, by possession of arecognized degree, certificate, professional standing, or skill,and who, by knowledge, training, and experience, has demon-strated
46、the ability to deal with problems related to the subjectmatter, the work, or the project. 1451, 20133.3.22 Rebuild. Tomakeextensiverepairsinordertorestorea component to like-new condition in accordance with theoriginal manufacturers specifications.3.3.23 Repair. To restore to sound condition after f
47、ailure ordamage. 1911, 20123.3.24 Requisite Knowledge. Fundamental knowledge onemust have in order to perform a specific task. 1031, 20143.3.25 Requisite Skills. The essential skills one must have inorder to perform a specific task. 1031, 20143.3.26 Standard Operating Procedures (SOPs). Written in-s
48、tructions that document and define the manner in which ac-tivities should be conducted. 1404, 20133.3.27 Structural Integrity. An unimpaired condition of anycomponent.3.3.28 Task. Aspecific job behavior or activity. 1002, 20143.3.29 Test. To verify serviceability by measuring the me-chanical, pneuma
49、tic, hydraulic, or electrical characteristics ofan item and comparing those characteristics with prescribedstandards. 1911, 2012Chapter 4 Emergency Vehicle Technician I4.1 General. To be considered qualified as an Emergency Ve-hicleTechnicianI,theindividualshallhavethegeneralknowl-edge defined in 4.1.1 and the general skills defined in 4.1.2and shall meet the job performance requirements of through4.4 and at least one specialty area as defined in Section 4.5,Section 4.6, or Section 4.7.4.1.1*GeneralKnowledgeRequirements.Theorganizationofthe fire d
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1