1、 TIA-222-G-4 (Addendum to TIA-222-G) December 2014Structural Standards for Steel Antenna Towers and Antenna Supporting Structures- Addendum 4 ANSI/TIA-222-G-4-2014 APPROVED: DECEMBER 15, 2014 NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminat
2、ing misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publications shall not
3、in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or internationally. St
4、andards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Stand
5、ard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its us
6、e. Any use of trademarks in this document are for information purposes and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Project No. ANSI/TIA-PN-222-G-4, formulated under the cognizance of the TIA TR-14 Structural Standards for Communicat
7、ion and Small Wind Turbine Support Structures). Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology and Standards Department 1320 N. Courthouse Road, Suite 200 Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION STANDARDS AND E
8、NGINEERING PUBLICATIONS or call IHS, USA and Canada (1-877-413-5187) International (303-397-2896) or search online at http:/www.tiaonline.org/standards/catalog/ All rights reserved Printed in U.S.A. NOTICE OF COPYRIGHT This document is copyrighted by the TIA. Reproduction of these documents either i
9、n hard copy or soft copy (including posting on the web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact the TIA Standards Department or go to the TIA website (www.tiaonline.org) for details on how to request permission. Deta
10、ils are located at: http:/www.tiaonline.org/standards/catalog/info.cfm#copyright or Telecommunications Industry Association Technology (b) there is no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any other form; (c) the Document may be amen
11、ded, modified or changed in the standards development or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investi
12、gation for IPR. When IPR consisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate
13、 or inquire into, the scope or validity of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or conditions are reasonable or non-discriminato
14、ry. TIA does not warrant or represent that procedures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References to a document published by another organization (“other SSO”) engaged in
15、the formulation, development or publication of standards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined in the TIA Procedures for American National Standards) then (i) TIA discla
16、ims any duty or obligation to search or investigate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see TIA Procedures for American National Standards Annex C.1.2.3) of Essential Patent(
17、s) and published pending patent applications shall apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) or published pending patent applications. TIA does not enforce or monitor c
18、ompliance with the contents of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANT
19、IES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES N
20、O REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR AN
21、Y AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BAS
22、ED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY
23、TIA WITHOUT SUCH LIMITATIONS. ANSI/TIA-222-G Addendum 4 1 Small Wind Turbine Support Structures TABLE OF CONTENTS OBJECTIVE 3 SCOPE 3 1.0 GENERAL 3 1.1 Design Criteria 3 1.2 Turbine Model 4 1.3 Definitions 4 1.4 Abbreviations 4 2.0 TURBINE MANUFACTURER DATA 5 3.0 EFFECTIVE PROJECTED AREA 5 4.0 DRAG
24、FACTORS FOR POLE STRUCTURES 6 5.0 EXTREME WIND CONDITION 6 6.0 EXTREME ICE CONDITION 6 7.0 EXTREME EARTHQUAKE CONDITION 7 8.0 CRITICAL TURBINE MOMENTS 7 9.0 STIFFNESS REQUIREMENTS FOR TOP MOUNTED TURBINES 7 10.0 DYNAMIC REQUIREMENTS 7 11.0 DESIGN FOR FATIGUE 8 11.1 Equivalent Constant Range Fatigue
25、Wind Loading on 8 Supporting Structure 11.2 Equivalent Constant Range Fatigue Turbine Loads 9 11.3 Fatigue Analysis 10 11.4 Design Stress Ranges 11 11.5 Miscellaneous Requirements for Fatigue Strength 16 ANSI/TIA-222-G Addendum 4 12.0 OTHER STRUCTURAL MATERIALS 17 12.1 Extreme Loading Conditions 18
26、12.2 Fatigue Loading Condition 18 13.0 FOUNDATIONS 18 14.0 MAINTENANCE AND CONDITION ASSESSMENT 18 15.0 MODIFICATION OF SUPPORT STRUCTURES 19 REFERENCE TABLES 20 ANNEX A: REFERENCES (INFORMATIVE) 27 Note: Informative annexes contain additional information that are not considered part of the standard
27、. ANSI/TIA-222-G Addendum 4 3 Small Wind Turbine Support Structures OBJECTIVE The objective of this Standard is to provide recognized literature intended to be used in conjunction with the ANSI/TIA-222-G-2 Standard, “Structural Standard for Antenna Supporting Structures and Antennas” (TIA) for the d
28、esign and analysis of structures supporting Small Wind Turbines (SWTs) defined as wind turbines with rotor swept areas less than 2,200 sq. feet 200 sq. m. This Standard defines how specific portions of TIA shall be applied to SWT supporting structures and provides supplementary requirements that per
29、tain specifically to the unique characteristics of SWT supporting structures. Provisions of this Standard have been derived from the IEC 61400-2 Standard, “Wind Turbines - Part 2: Design Requirements for Small Wind Turbines” (IEC) and other industry standards. The provisions of this Standard are int
30、ended to represent the minimum structural standards for SWT support structures. The user is cautioned that turbine specific requirements for the supporting structure specified by the turbine manufacturer may take precedence over the minimum requirements of this standard. All precautions and warnings
31、 outlined in TIA also apply to this Standard. SCOPE This Standard is intended to apply to self-supporting or bracketed latticed towers, guyed masts and tubular pole structures that support small wind turbines that may also support antennas and other appurtenances. The design and analysis of turbine
32、components are not included within the scope of this Standard. Strength requirements for erection and maintenance are not within the scope of this Standard. Refer to the ANSI/TIA-1019-A Standard “Standard for Installation, Alteration and Maintenance of Antenna Supporting Structures and Antennas” for
33、 construction considerations and strength requirements. 1.0 GENERAL 1.1 Design Criteria SWT supporting structures including foundations shall be in conformance with the requirements of TIA and the additional supplementary requirements of this Standard. Turbine operating loading conditions are not co
34、nsidered in this Standard unless specific loading and associated wind conditions are specified by the turbine manufacturer. It is assumed that the requirements specified in this Standard govern over the requirements for normal turbine operating conditions. Conformance to this Standard is not require
35、d for structures supporting wind turbines with rotor swept areas less than 22 sq. feet 2 sq. m. Structures supporting turbines with rotor swept areas less than 22 sq. feet 2 sq. m may be designed and/or analyzed in accordance with TIA considering each turbine as an appurtenance with the effective pr
36、ojected area of each turbine determined in accordance with Section 3.0. The effective projected area shall be considered to ANSI/TIA-222-G Addendum 4 be constant for all wind directions. The wind force based on the effective projected area of each turbine shall be considered as a wind load using a l
37、oad factor equal to 1.6 and a wake interference factor, Ka, equal to 1.0. Mast type supports for all small wind turbines, regardless of swept area, shall conform to this Standard. 1.2 Turbine Model A turbine shall be modeled as a mass and an effective projected area. For the fatigue loading conditio
38、n specified in Section 11.0, wind loads from the effective projected area of the turbine shall be replaced with the equivalent constant range fatigue turbine loads specified in 11.2. Unless otherwise specified, the center of mass and the centroid of the effective projected area shall be considered t
39、o be at the hub height for horizontal axis turbines and the mid-turbine height for vertical axis turbines and assumed to be distributed symmetrically about the vertical centerline of the turbine base connection to the supporting structure. For investigating the extreme loading conditions specified i
40、n Sections 5.0 through 8.0, when a horizontal offset of the turbine center of mass from the vertical centerline of the turbine base is specified by the turbine manufacturer, the additional overturning moment on the supporting structure due to turbine weight shall be considered to occur in the direct
41、ion which adds to the overturning moment from the horizontal force from the turbine. For the purpose of determining factored extreme loading conditions, turbine weight shall be considered as dead load and turbine forces and moments shall be considered as wind or earthquake loads. 1.3 Definitions Equ
42、ivalent constant range fatigue load: a constant amplitude load range intended to represent the fatigue effects of actual variable amplitude loading events. Flange plate: a base, top or intermediate flange welded to a latticed tower leg or tubular pole structure. Hub height above turbine base: the he
43、ight of the center of the wind turbine rotor above the turbine base connection to the supporting structure (for horizontal axis turbines). Initial tension condition: the equilibrium position of a guyed mast (with corresponding forces in the components of the mast) with guys at their specified instal
44、lation tension. Turbine base: the base of the turbine that interfaces with the supporting structure. 1.4 Abbreviations AWEA American Wind Energy Association Standard AWEA 9.1 EPA Effective Projected Area (projected area times drag factor) IEC International Electrotechnical Commission Standard 61400-
45、2 SWT Small Wind Turbine ANSI/TIA-222-G Addendum 4 5 TIA Telecommunications Industry Association Standard ANSI/TIA-222-G-2 2.0 TURBINE MANUFACTURER DATA The following turbine data shall be provided by the turbine manufacturer: 1. Type of turbine: horizontal or vertical axis machine 2. Rotor diameter
46、, feet m 3. Rotational rotor speed at AWEA electrical power rating of turbine, RPM 4. Hub height (horizontal axis turbines) or mid-turbine height (vertical axis turbines) above turbine base connection to supporting structure, feet m 5. Maximum turbine horizontal thrust in parked stationary position
47、(unfactored), pounds N 6. Wind speed at hub height associated with the specified maximum turbine horizontal thrust, mph m/s 7. Weight of turbine, pounds N 8. Horizontal offset of turbine center of mass from vertical centerline of turbine base, feet m 9. Weight of rotor (blades and hub), pounds N 10.
48、 Distance from center of rotor mass to vertical centerline of turbine base, feet m 11. Critical turbine operating moments (unfactored), foot-pounds N-m 12. Clearance requirements of turbine blades (considering deflected shape of blades and supporting structure) 13. Connection details for the turbine base to the supporting structure including required tolerances 14. Natural frequencies and other limitations