1、STD-CEPT I-ETS 300 440-ENGL L994 D 232b4L4 00/4958 686 W ER0 Report form for testing to I-ETS 300 440 Short Range Devices Technical characteristics and test methods for radio equipment to be used in the 1 GHr to 25 GHr frequency range The submission documentation to a National Regulatory Body for Ty
2、pe approval purposes shall consist of two parts; Part one. Application form Part two. Test report form Important copvriciht notice: No modification whatsoever of any part of the text of this Report Form may be made. The only amendments permissible in reproduction are modifications to the layout, enl
3、arge- ment of the fields or the addition of logos of test laboratories making use of this form. Version: Adopted by ERC WG RR: 1 2/94 November 1995 Published by: European Radiocommunications Office cs- From 1 May 1996 Telephone: +45 35 43 24 42 Holsteinsgade 63 Midtermolen 1 Telefax: -1-45 35 43 35
4、14 DK-21 O0 Copenhagen DK-2100 Copenhagen BBS: +45 35 43 27 81 Denmark Denmark Internet: http:/www.ERO. DKK STD-CEPT I-ETS 300 440-ENGL 1994 W 2326414 0034959 532 nLr un I I univi I un I LQ I IIYU I w I-L I e duu -.*u The accreditation terms of the laboratory will prescribe the format and content of
5、 the title page. As a minimum the title page should include the following: 1. Name of the laboratory performing the tests 2. Test report reference number 3. 4. The name of the manufacturer Reference to I-ETS 300 440 5. Manufacturer?s declared type designation 6. The type of equipment (e.g. fixed sta
6、tion, mobile station, portable station, plug-in card) 7. Equipment serial number 1 STDmCEPT I-ETS 300 440-ENGL 1994 m 232b41i4 00143b0 23Y m nLr wn I I wnivi I un I 1-4 I IIYU I w I-L I o rw -tu The test laboratory should note the following when using the test report form: I. 2. 3. 4. 5. 6. 7. 8. 9.
7、 1 o. NOTE In the “list of measurements“, sub-clause numbers have not been included because full testing may not be required in all cases. The test laboratory should enter the sub-clause numbers of tests actually conducted in each case. The relevant reference number from the list “Test equipment and
8、 ancillaries used for tests“ should be entered under the heading “Test equipment used“ for each test. For equipment designed for intermittent use, take care that the stated duty cycle is not exceed. The actual duty cycle used should be stated on the test report. Where the equipment under test can no
9、t be tested in an unmodulated condition, then full description of the modulated signal should be given. For equipment with an integral antenna state, where applicable, whether a test fixture, temporary connector or permanent internal connector is used. For battery operated equipment, state whether t
10、he recommended internal batteries are used or the external test power source. For radiated measurements state the type of test site used. It is recommended that where clarification of a test method or an agreed test procedure is required, this should be described on the final page of the test report
11、 title “Additional information supplementary to the standard test report“. The bandwidth column in the spurious emission tables refers to the bandwidth of the measuring receiver. No undefined abbreviations are to be used in the test report. Page numbers have been temporarily added to the TEST REPORT
12、 FORM to facilitate drafting. When the document is approved the numbers will be removed. 2 STDmCEPT I-ETS 300 440-ENGL 1994 232b414 00149b3 170 I LU I nLr un I nu LnLIvwL LIST OF MEASUREMENTS The complete list of measurements called for in I-ETS 300-440 is given below. The complete list of measureme
13、nts called for in I-ETS 300-440 is given below. SUBCLAUSE PARAMETER TO BE MEASURED Transmitter parameters Equivalent isotropically radiated power Operating frequency range Spurious emissions conducted - Transmitter operating Spurious emissions conducted - Transmitter on Standby Spurious emissions ra
14、diated - Transmitter operating Spurious emissions radiated - Transmitter on Standby Receiver parameters Spurious radiations - Conducted Spurious radiations - Radiated PAOE . . , . . , . . 3 STD-CEPT I-ETS 300 440-ENGL 1994 TEST REPORT REFERENCE Ambient temperature OC EQUIVALENT ISOTROPICALLY RADIATE
15、D POWER Rated output power (maximum) . Antenna (where applicable): Reference No. Bandwidth of measurement receiver. W Class I II 232b414 0014962 007 rnuL VI Radiated peak power (e.i.r.p.) W 5,O .e f 5 20,O GHz 1 ,O I f I5,O GHz 20 c f GHz 100mW 10 mW 25 mW 500 mW Relative humidity ?6 SUBCLAUSE 7.1 G
16、ain dBi LIMIT SUBCLAUSE 7.1.3 III I 500 mW I 2w I A separate page shall be filled in for each antenna assembly submitted for type testing. REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 4 STDmCEPT I-ETS 300 440-ENGL TEST REPORT REFERENCE Ambient temperature “C
17、OPERATING FREQUENCY RANGE Applicants declared operating frequency band: Lowest frequency GHz 1994 2326414 0014763 T43 m rnuL VI Relative humidity % SUBCLAUSE 7.2 Highest frequency GHz Limit Frequency GHz Test conditions I Tnom( .)OC v-(. . .)V Ill Measurement uncertainty Hz Where FL FH Lowest freque
18、ncy at the appropriate spurious emission level Highest frequency at the appropriate spurious emission level Band edge limits FL = Lowest FL (measured) FH = Highest FH (measured) and REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 5 STD-CEPT I-ETS 300 440-ENGL 19
19、94 TEST REPORT REFERENCE Measuring receiver bandwidth (MHz) Ambient temperature . .O C TRANSM ITER SPURIOUS EM ISS1 ONS (CON DUCTED) Rated output power W Transmitter operating/ctandby* Frequency hopping/static* _ Spurious emissions level (nW) W 232b4L4 00L49b4 98T rnuL VI State Operating Standby Rel
20、ative humidity % SUBCLAUSE 7.3.3 47 to 74 MHz Other frequencies Frequencies 1 O00 87,5 to 11 8 MHz 174 to 230 MHz 470 to 862 MHz 2 25 to 5 lo00 MHz MHz 4 nW 250 nW 1 ww 2 nW 2 nW 20 nW Modulated/Unmodulated* *(Delete whichever is inappropriate) Measurement uncertainty (dB) LIMIT SUBCLAUSE 7.3.7 REFE
21、RENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 6 STD-CEPT I-ETS 300 440-ENGL 1994 TEST REPORT REFERENCE Ambient temperature OC TRANSMITTER SPURIOUS EMISSIONS (RADIATED) Rated output power W Transmitter operating/standby* Frequency hopping/static* f (MH4 M 232b414 O
22、014965 8Lb = rnuL VI Measuring receiver bandwidth Spurious emissions level (nW) (MHz) Relative humidity % SUBCLAUSE7.3.4 Short range devices; Technical characteristics and test methods for radio equipment to be used in the 1 GHz to 25 GHz frequency range Adm I Imp1 1 Remarks AUT I Yes I Yes Yes 2.9.1997. Regulation on technical requirements for radio stations, art. 17 (ff.Gaz. of SVN, No. 50/97) in accordance with T/R O1 -04
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1