CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf

上传人:deputyduring120 文档编号:592952 上传时间:2018-12-16 格式:PDF 页数:15 大小:336.56KB
下载 相关 举报
CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf_第1页
第1页 / 共15页
CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf_第2页
第2页 / 共15页
CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf_第3页
第3页 / 共15页
CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf_第4页
第4页 / 共15页
CEPT I-ETS 300 440-1994 Technical Characteristics and Test Methods for Radio Equipment to be Used in the 1 GHz to 25 GHz Frequency Range《要在1 GHz-25 GHz频率范围中使用的无线电设备技术特征和测试方法》.pdf_第5页
第5页 / 共15页
亲,该文档总共15页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、STD-CEPT I-ETS 300 440-ENGL L994 D 232b4L4 00/4958 686 W ER0 Report form for testing to I-ETS 300 440 Short Range Devices Technical characteristics and test methods for radio equipment to be used in the 1 GHr to 25 GHr frequency range The submission documentation to a National Regulatory Body for Ty

2、pe approval purposes shall consist of two parts; Part one. Application form Part two. Test report form Important copvriciht notice: No modification whatsoever of any part of the text of this Report Form may be made. The only amendments permissible in reproduction are modifications to the layout, enl

3、arge- ment of the fields or the addition of logos of test laboratories making use of this form. Version: Adopted by ERC WG RR: 1 2/94 November 1995 Published by: European Radiocommunications Office cs- From 1 May 1996 Telephone: +45 35 43 24 42 Holsteinsgade 63 Midtermolen 1 Telefax: -1-45 35 43 35

4、14 DK-21 O0 Copenhagen DK-2100 Copenhagen BBS: +45 35 43 27 81 Denmark Denmark Internet: http:/www.ERO. DKK STD-CEPT I-ETS 300 440-ENGL 1994 W 2326414 0034959 532 nLr un I I univi I un I LQ I IIYU I w I-L I e duu -.*u The accreditation terms of the laboratory will prescribe the format and content of

5、 the title page. As a minimum the title page should include the following: 1. Name of the laboratory performing the tests 2. Test report reference number 3. 4. The name of the manufacturer Reference to I-ETS 300 440 5. Manufacturer?s declared type designation 6. The type of equipment (e.g. fixed sta

6、tion, mobile station, portable station, plug-in card) 7. Equipment serial number 1 STDmCEPT I-ETS 300 440-ENGL 1994 m 232b41i4 00143b0 23Y m nLr wn I I wnivi I un I 1-4 I IIYU I w I-L I o rw -tu The test laboratory should note the following when using the test report form: I. 2. 3. 4. 5. 6. 7. 8. 9.

7、 1 o. NOTE In the “list of measurements“, sub-clause numbers have not been included because full testing may not be required in all cases. The test laboratory should enter the sub-clause numbers of tests actually conducted in each case. The relevant reference number from the list “Test equipment and

8、 ancillaries used for tests“ should be entered under the heading “Test equipment used“ for each test. For equipment designed for intermittent use, take care that the stated duty cycle is not exceed. The actual duty cycle used should be stated on the test report. Where the equipment under test can no

9、t be tested in an unmodulated condition, then full description of the modulated signal should be given. For equipment with an integral antenna state, where applicable, whether a test fixture, temporary connector or permanent internal connector is used. For battery operated equipment, state whether t

10、he recommended internal batteries are used or the external test power source. For radiated measurements state the type of test site used. It is recommended that where clarification of a test method or an agreed test procedure is required, this should be described on the final page of the test report

11、 title “Additional information supplementary to the standard test report“. The bandwidth column in the spurious emission tables refers to the bandwidth of the measuring receiver. No undefined abbreviations are to be used in the test report. Page numbers have been temporarily added to the TEST REPORT

12、 FORM to facilitate drafting. When the document is approved the numbers will be removed. 2 STDmCEPT I-ETS 300 440-ENGL 1994 232b414 00149b3 170 I LU I nLr un I nu LnLIvwL LIST OF MEASUREMENTS The complete list of measurements called for in I-ETS 300-440 is given below. The complete list of measureme

13、nts called for in I-ETS 300-440 is given below. SUBCLAUSE PARAMETER TO BE MEASURED Transmitter parameters Equivalent isotropically radiated power Operating frequency range Spurious emissions conducted - Transmitter operating Spurious emissions conducted - Transmitter on Standby Spurious emissions ra

14、diated - Transmitter operating Spurious emissions radiated - Transmitter on Standby Receiver parameters Spurious radiations - Conducted Spurious radiations - Radiated PAOE . . , . . , . . 3 STD-CEPT I-ETS 300 440-ENGL 1994 TEST REPORT REFERENCE Ambient temperature OC EQUIVALENT ISOTROPICALLY RADIATE

15、D POWER Rated output power (maximum) . Antenna (where applicable): Reference No. Bandwidth of measurement receiver. W Class I II 232b414 0014962 007 rnuL VI Radiated peak power (e.i.r.p.) W 5,O .e f 5 20,O GHz 1 ,O I f I5,O GHz 20 c f GHz 100mW 10 mW 25 mW 500 mW Relative humidity ?6 SUBCLAUSE 7.1 G

16、ain dBi LIMIT SUBCLAUSE 7.1.3 III I 500 mW I 2w I A separate page shall be filled in for each antenna assembly submitted for type testing. REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 4 STDmCEPT I-ETS 300 440-ENGL TEST REPORT REFERENCE Ambient temperature “C

17、OPERATING FREQUENCY RANGE Applicants declared operating frequency band: Lowest frequency GHz 1994 2326414 0014763 T43 m rnuL VI Relative humidity % SUBCLAUSE 7.2 Highest frequency GHz Limit Frequency GHz Test conditions I Tnom( .)OC v-(. . .)V Ill Measurement uncertainty Hz Where FL FH Lowest freque

18、ncy at the appropriate spurious emission level Highest frequency at the appropriate spurious emission level Band edge limits FL = Lowest FL (measured) FH = Highest FH (measured) and REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 5 STD-CEPT I-ETS 300 440-ENGL 19

19、94 TEST REPORT REFERENCE Measuring receiver bandwidth (MHz) Ambient temperature . .O C TRANSM ITER SPURIOUS EM ISS1 ONS (CON DUCTED) Rated output power W Transmitter operating/ctandby* Frequency hopping/static* _ Spurious emissions level (nW) W 232b4L4 00L49b4 98T rnuL VI State Operating Standby Rel

20、ative humidity % SUBCLAUSE 7.3.3 47 to 74 MHz Other frequencies Frequencies 1 O00 87,5 to 11 8 MHz 174 to 230 MHz 470 to 862 MHz 2 25 to 5 lo00 MHz MHz 4 nW 250 nW 1 ww 2 nW 2 nW 20 nW Modulated/Unmodulated* *(Delete whichever is inappropriate) Measurement uncertainty (dB) LIMIT SUBCLAUSE 7.3.7 REFE

21、RENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference see test equipment listing) 6 STD-CEPT I-ETS 300 440-ENGL 1994 TEST REPORT REFERENCE Ambient temperature OC TRANSMITTER SPURIOUS EMISSIONS (RADIATED) Rated output power W Transmitter operating/standby* Frequency hopping/static* f (MH4 M 232b414 O

22、014965 8Lb = rnuL VI Measuring receiver bandwidth Spurious emissions level (nW) (MHz) Relative humidity % SUBCLAUSE7.3.4 Short range devices; Technical characteristics and test methods for radio equipment to be used in the 1 GHz to 25 GHz frequency range Adm I Imp1 1 Remarks AUT I Yes I Yes Yes 2.9.1997. Regulation on technical requirements for radio stations, art. 17 (ff.Gaz. of SVN, No. 50/97) in accordance with T/R O1 -04

展开阅读全文
相关资源
猜你喜欢
  • BS EN ISO 8510-2-2010 Adhesives Peel test for a flexible-bonded-to-rigid test specimen assembly 180 degree peel《粘合剂 软料与硬料粘合试样组件剥离试验 180剥离》.pdf BS EN ISO 8510-2-2010 Adhesives Peel test for a flexible-bonded-to-rigid test specimen assembly 180 degree peel《粘合剂 软料与硬料粘合试样组件剥离试验 180剥离》.pdf
  • BS EN ISO 8528-13-2016 Reciprocating internal combustion engine driven alternating current generating sets Safety《往复式内燃机驱动的交流发电机组 安全性》.pdf BS EN ISO 8528-13-2016 Reciprocating internal combustion engine driven alternating current generating sets Safety《往复式内燃机驱动的交流发电机组 安全性》.pdf
  • BS EN ISO 8534-2017 Animal and vegetable fats and oils Determination of water content Karl Fischer method (pyridine free)《动物和植物的脂肪和油 水分的测定 卡尔·费休法(无吡啶)》.pdf BS EN ISO 8534-2017 Animal and vegetable fats and oils Determination of water content Karl Fischer method (pyridine free)《动物和植物的脂肪和油 水分的测定 卡尔·费休法(无吡啶)》.pdf
  • BS EN ISO 8536-1-2011 Infusion equipment for medical use Infusion glass bottles《医用输液设备 输液玻璃瓶》.pdf BS EN ISO 8536-1-2011 Infusion equipment for medical use Infusion glass bottles《医用输液设备 输液玻璃瓶》.pdf
  • BS EN ISO 8536-10-2015 Infusion equipment for medical use Accessories for fluid lines for single use with pressure infusion equipment《医用输液设备 与压力输液仪器一起单一使用的输液管附件》.pdf BS EN ISO 8536-10-2015 Infusion equipment for medical use Accessories for fluid lines for single use with pressure infusion equipment《医用输液设备 与压力输液仪器一起单一使用的输液管附件》.pdf
  • BS EN ISO 8536-11-2015 Infusion equipment for medical use Infusion filters for single use with pressure infusion equipment《医用输液设备 与压力输液仪器一起单一使用的输液过滤器》.pdf BS EN ISO 8536-11-2015 Infusion equipment for medical use Infusion filters for single use with pressure infusion equipment《医用输液设备 与压力输液仪器一起单一使用的输液过滤器》.pdf
  • BS EN ISO 8536-13-2016 Infusion equipment for medical use Graduated flow regulators for single use with fluid contact《输液用医疗器械 一次性流体接触的刻度式流体调节器》.pdf BS EN ISO 8536-13-2016 Infusion equipment for medical use Graduated flow regulators for single use with fluid contact《输液用医疗器械 一次性流体接触的刻度式流体调节器》.pdf
  • BS EN ISO 8536-2-2010 Infusion equipment for medical use - Closures for infusion bottles《医用输液设备 输液瓶塞》.pdf BS EN ISO 8536-2-2010 Infusion equipment for medical use - Closures for infusion bottles《医用输液设备 输液瓶塞》.pdf
  • BS EN ISO 8536-3-2009 Infusion equipment for medical use - Part 3 Aluminium caps for infusion bottles (ISO 8536-3 2009)《医用输液设备 第3部分 输液瓶的铝制瓶盖(ISO 8536-3-2009)》.pdf BS EN ISO 8536-3-2009 Infusion equipment for medical use - Part 3 Aluminium caps for infusion bottles (ISO 8536-3 2009)《医用输液设备 第3部分 输液瓶的铝制瓶盖(ISO 8536-3-2009)》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1