1、INCH-POUND MIL-DTL-5423/16E 17 February 2009 SUPERSEDING MIL-DTL-5423/16D AMENDMENT 1 12 May 2003 DETAIL SPECIFICATION SHEET BOOT, DUST AND WATER SEAL, BUSHING SEAL, TYPE A (FOR TOGGLE SWITCH 0.469 DIAMETER) STYLE 10 (PANEL BUSHING SEAL ONLY) This specification sheet is approved for use by all Depar
2、tments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-5423. ALTERNATE CONFIGURATION BOTH VERSIONS ARE ACCEPTABLE AND ARE MUTUALLY INTERCHANGEABLE PROVIDED THEY MEET THE SPECIFIED REQUIREMENT
3、S FIGURE 1. Dimensions and configuration boots type A, style 10. AMSC N/A FSC 5930 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5423/16E 2 DETAIL OF BUSHING SEAL ASSEMBLY Inches mm Inches mm .015 0.38 .420 10.67 .062 1.57 .432 10.97 .072 1
4、.83 .461 11.71 .083 2.11 .472 11.99 .105 2.67 .650 16.51 .120 3.05 .677 17.20 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .15 (0.38 mm) for three place decimals. 4. This seal is intended for use with
5、toggle switches per MIL-DTL-3950, MIL-DTL-8834, and MIL-DTL-83731. 5. Bushing seal to be assembled so that surface marked “Top” is up, or “Bottom” is down. FIGURE 1. Dimensions and configuration boots type A, style 10 Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted wi
6、thout license from IHS-,-,-MIL-DTL-5423/16E 3 REQUIREMENTS Dimensions and configuration: See figure 1. Silicon rubber: Grade 50. Qualification: First Article Testing in accordance with MIL-DTL-5423. Watertightness: The boot (bushing seal) shall be assembled to the test enclosure using a solid bushin
7、g of dimensions equivalent to a bushing of an applicable switch (including the non-turn notch). The solid bushing and bushing seal shall be assembled per figure I. The test shall be conducted in accordance with the “Final” watertightness test of MIL-DTL-5423, except that the pressure shall be limite
8、d to 6 pounds-force per square inch gauge, external pressure only, and no operations are required. At the conclusion of this procedure, the test enclosure shall be examined in the bushing area for evidence of water leakage. The following tests are not required: Restoring force, durability, sand and
9、dust, vibration, salt spray, endurance and lubricant. Part or Identifying Number (PIN): M5423/16-01 The margins of this specification are marked with vertical lines to indicate where modifications were made. This was done as a convenience only and the Government assumes no liability whatsoever for a
10、ny inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Reference Documents: MIL-DTL-5423 MIL-DTL-3950 MIL-DTL-8834 MIL-DTL-83731 Custodians: Preparing activity: Army -
11、 CR DLA - CC Navy - AS Air Force - 85 (Project 5930-2008-072) DLA - CC Review activities: Army AT, AV, CR4, MI Navy CG, EC, MC, OS Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1