1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards DEPOSIT BOX REAR FLOOR COVER TEST PROCEDURE Do Not Use on New Programs. Being Replaced by GMW14457 EDS-T-4303 ISSUED DATE: 2000. 09. 15 REVISED DATE: 2008. 10. 15 VERSION: 3 (Superceded) EDS-T-4303DEPOSIT BOX REAR FLO
2、OR COVER TEST PROCEDURE PAGE: 1/3 ISSUED DATE: 2000. 09. 15 REVISED DATE: 2008. 10. 15 VERSION: 3 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW14457. 1. PURPOSE This standard
3、aims at specifying the method of checking the operating effort and durability of the cover A-D/box, RR floor hereinafter called “floor cover”). 2. SCOPE This standard applies only to the floor cover for passenger cars. Details not specified here shall conform to the requirements in drawings. 3. TEST
4、 EQUIPMENT 3.1. Fixture jig 3.2. Hydraulic cylinder & control box 3.3. Push-pull gauge 3.4. Hot-cold chamber 4. PREPARATION OF TEST SAMPLE 4.1. No of test samples Three finished test samples shall be used for approval test. 4.2. Requirements of test sample The test sample shall show no signs of defe
5、cts in visual inspection. 5. TEST METHOD AND REQUIREMENTS The sample shall meet all the following requirements: 5.1. Preparation for test 5.1.1. Mount the floor cover assy to the test jig in the vehicle condition. 5.1.2. Operate the sample 10 times prior to test. 5.2. Operating effort 5.2.1. Test me
6、thod (1) Using the push-pull gauge, measure the open effort around the grip. EDS-T-4303DEPOSIT BOX REAR FLOOR COVER TEST PROCEDURE PAGE: 2/3 ISSUED DATE: 2000. 09. 15 REVISED DATE: 2008. 10. 15 VERSION: 3 GM DAEWOO Auto & Technology (2) Unless specified otherwise, the open effort shall be measured b
7、y applying the load to the cover tip at an angle of 8090with respect to the cover. See Fig 1. Figure 1 5.2.2. Requirements Unless specified otherwise in drawings, the open effort before and after durability test shall be 1030N. 5.3. Durability test 5.3.1. Test method With opening of the floor cover
8、to the full from the closed state (opening angle: Min 110) and subsequent closing to the original closed state as 1 cycle, perform test at a rate of 4 cycles a minute. Test sequence Temperature condition No of cycle 1 Ambient 3,000 2 70 500 3 -30 500 EDS-T-4303DEPOSIT BOX REAR FLOOR COVER TEST PROCE
9、DURE PAGE: 3/3 ISSUED DATE: 2000. 09. 15 REVISED DATE: 2008. 10. 15 VERSION: 3 GM DAEWOO Auto & Technology Figure 2 5.3.2. Requirements Each part shall show no signs of deformation, breakage, abnormal noise, poor opening, cracks, etc after open-close durability test under each temperature condition. 6. CODING This test method shall be called up in drawings as follows: “The parts must comply with EDS-T-4303.” Additional requirements other than those in this standard shall be indicated in drawings and shall prevail over this standard.
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1