1、 Tentative Interim Amendment NFPA13 Standard for the Installation of Sprinkler Systems 2016 Edition Reference: 8.5.5.3.1.1(New) TIA 16-6 (SC 16-8-7 / TIA Log #1225) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the National Fire Protection Association has

2、 issued the following Tentative Interim Amendment to NFPA 13, Standard for the Installation of Sprinkler Systems, 2016 edition. The TIA was processed by the Technical Committee on Sprinkler System Installation Criteria and the Correlating Committee on Automatic Sprinkler Systems, and was issued by t

3、he Standards Council on August 4, 2016, with an effective date of August 24, 2016. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatic

4、ally becomes a public input of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. Add a new paragraph 8.5.5.3.1.1 and renumber subsequent paragraphs to read as follows: 8.5.5.3.1* Sprinklers shall be installed

5、under fixed obstructions over 4 ft (1.2 m) in width. 8.5.5.3.1.1 Open grate flooring over 4 ft (1.2 m) in width shall require sprinkler protection below the grating. 8.5.5.3.1.2 Sprinklers shall be located below the obstruction and not more than 3 in. (75 mm) from the outside edge of the obstruction

6、 8.5.5.3.1.3 Where sprinklers are located adjacent to the obstruction, they shall be of the intermediate level rack type. 8.5.5.3.1.4 The deflector of automatic sprinklers installed under fixed obstructions shall be positioned no more than 12 in. (300 mm) below the bottom of the obstruction. 8.5.5.

7、3.1.5 Sprinklers shall not be required under noncombustible obstructions over 4 ft (1.2 m) wide where the bottom of the obstruction is 24 in. (600 mm) or less above the floor or deck. Issue Date: August 4, 2016 Effective Date: August 24, 2016 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/docinfo) Copyright 2016 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION

展开阅读全文
相关资源
猜你喜欢
  • STAS CEI 721-2-7-1993 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS Part 2 Environmental conditions appearing in nature Fauna and flora《环境条件分类 第2部分:自然中出现的环境条件 动物和植物 》.pdf STAS CEI 721-2-7-1993 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS Part 2 Environmental conditions appearing in nature Fauna and flora《环境条件分类 第2部分:自然中出现的环境条件 动物和植物 》.pdf
  • STAS CEI 731-1992 Medical electrical equipment Dosimeters with ionisation chambers as used in radiotherapy《医用电子设备 与放射治疗中使用相同的电离室放射量测定计》.pdf STAS CEI 731-1992 Medical electrical equipment Dosimeters with ionisation chambers as used in radiotherapy《医用电子设备 与放射治疗中使用相同的电离室放射量测定计》.pdf
  • STAS CEI 747-10-1992 Semiconductor devices Part 10 Generic specification for discrete devices and integrated circuits《半导体器件 第10部分:分离设备和集成电路的通用规格》.pdf STAS CEI 747-10-1992 Semiconductor devices Part 10 Generic specification for discrete devices and integrated circuits《半导体器件 第10部分:分离设备和集成电路的通用规格》.pdf
  • STAS CEI QC 001001-1992 Basic Rules of the IEC Quality Assessment System for Electronic Components (IECQ)《国际电工委员会质量评价系统对电子元件的基本要求 》.pdf STAS CEI QC 001001-1992 Basic Rules of the IEC Quality Assessment System for Electronic Components (IECQ)《国际电工委员会质量评价系统对电子元件的基本要求 》.pdf
  • STAS E 10702 2-1980 Protection of steel overground constructions PROTECTIVE COATINGS FOR CONSTRUCTIONS PLACED IN-NON-AGGRESSIVE OR WEAKLY- AGGRESSIVE MEDIUMS AND WITH MIDDLE AGGRES.pdf STAS E 10702 2-1980 Protection of steel overground constructions PROTECTIVE COATINGS FOR CONSTRUCTIONS PLACED IN-NON-AGGRESSIVE OR WEAKLY- AGGRESSIVE MEDIUMS AND WITH MIDDLE AGGRES.pdf
  • STAS E 10719 2-1986 Medical instruments RESISTANCE TESTING AT CORROSION AND REPEATED STERILIZATIONS STAINLESS STEEL MEDICAL INSTIUMENTS《医疗器械 抗腐蚀试验和反复消毒试验 不锈钢医疗器械 》.pdf STAS E 10719 2-1986 Medical instruments RESISTANCE TESTING AT CORROSION AND REPEATED STERILIZATIONS STAINLESS STEEL MEDICAL INSTIUMENTS《医疗器械 抗腐蚀试验和反复消毒试验 不锈钢医疗器械 》.pdf
  • STAS E 11017-1978 THREE PHASE ASYNCHRONOUS MOTORS WiTH SHORT-CIRCUITED ROTOR Test method for reliability《三相异步电机的短路转子可靠性测试法 》.pdf STAS E 11017-1978 THREE PHASE ASYNCHRONOUS MOTORS WiTH SHORT-CIRCUITED ROTOR Test method for reliability《三相异步电机的短路转子可靠性测试法 》.pdf
  • STAS E 11041-1977 Land reclamation works DRAINAGE OF IRIGATED GROUNDS Design specifications《土地复垦工程 灌溉地域排水 设计规范 》.pdf STAS E 11041-1977 Land reclamation works DRAINAGE OF IRIGATED GROUNDS Design specifications《土地复垦工程 灌溉地域排水 设计规范 》.pdf
  • STAS E 11115 4-1989 ENVIRONMENTAL CONDITIONS AND TEST PROCEDURES FOR AIRBORNE EQUIPMENT Temperature and height《机载设备的环境条件和试验程序 温度和高度》.pdf STAS E 11115 4-1989 ENVIRONMENTAL CONDITIONS AND TEST PROCEDURES FOR AIRBORNE EQUIPMENT Temperature and height《机载设备的环境条件和试验程序 温度和高度》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1