NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf

上传人:Iclinic170 文档编号:1008286 上传时间:2019-03-19 格式:PDF 页数:67 大小:2.90MB
下载 相关 举报
NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf_第1页
第1页 / 共67页
NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf_第2页
第2页 / 共67页
NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf_第3页
第3页 / 共67页
NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf_第4页
第4页 / 共67页
NFPA 13D-2016 Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (Effective Date 06 15 2015).pdf_第5页
第5页 / 共67页
点击查看更多>>
资源描述

1、NFPA 13D Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes 2016 Edition NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 An International Codes and Standards OrganizationIMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DI

2、SCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS NFPA codes, standards, recommended practices, and guides (“NFPA Standards”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute

3、. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on re and other safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or ve

4、rify the accuracy of any information or the soundness of any judgments contained in NFPA Standards. The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting fro

5、m the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information published herein. In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on

6、 behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of

7、reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document. Any certication or o

8、ther statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the responsibility of the certier or maker of the statement. REMINDER: UPDATING OF NFPA STANDARDS Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards

9、”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendment and any Erra

10、ta then in effect. In order to determine whether an NFPA Standard has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, visit the Document Information Pages on NFPAs website. The Document Information Pages provide up-to-date, document specic information includ

11、ing any issued Tentative Interim Amendments and Errata. To access the Document Information Page for a specic NFPA Standard, go to http:/www.nfpa.org/docinfo to choose from the list of NFPA Standards or use the search feature on the right to select the NFPA Standard number (e.g., NFPA 101). In additi

12、on to posting all existing Tentative Interim Amendments and Errata, the Document Information Page also includes the option to sign-up for an “Alert” feature to receive an email notication when new updates and other information are posted regarding the document. ISBN: 978-145591157-8 (Print) ISBN: 97

13、8-145591194-3 (PDF)IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS ADDITIONAL NOTICES AND DISCLAIMERS Updating of NFPA Standards Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that these documents may be superseded at any time by the

14、issuance of new editions or may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendments and any Errata then in

15、 effect. In order to determine whether a given document is the current edition and whether it has been amended through the issuance of Tentative Interim Amendments or corrected through the issuance of Errata, consult appropriate NFPA publications such as the National Fire Codes Subscription Service,

16、 visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed below. Interpretations of NFPA Standards A statement, written or oral, that is not processed in accordance with Section 6 of the Regulations Governing the Development of NFPA Standards shall not be considered the ofci

17、al position of NFPA or any of its Committees and shall not be considered to be, nor be relied upon as, a Formal Interpretation. Patents The NFPA does not take any position with respect to the validity of any patent rights referenced in, related to, or asserted in connection with an NFPA Standard. Th

18、e users of NFPA Standards bear the sole responsibility for determining the validity of any such patent rights, as well as the risk of infringement of such rights, and the NFPA disclaims liability for the infringement of any patent resulting from the use of or reliance on NFPA Standards. NFPA adheres

19、 to the policy of the American National Standards Institute (ANSI) regarding the inclusion of patents in American National Standards (“the ANSI Patent Policy”), and hereby gives the following notice pursuant to that policy: NOTICE: The users attention is called to the possibility that compliance wit

20、h an NFPA Standard may require use of an invention covered by patent rights. NFPA takes no position as to the validity of any such patent rights or as to whether such patent rights constitute or include essential patent claims under the ANSI Patent Policy. If, in connection with the ANSI Patent Poli

21、cy, a patent holder has led a statement of willingness to grant licenses under these rights on reasonable and nondiscriminatory terms and conditions to applicants desiring to obtain such a license, copies of such led statements can be obtained, on request, from NFPA. For further information, contact

22、 the NFPA at the address listed below. Law and Regulations Users of NFPA Standards should consult applicable federal, state, and local laws and regulations. NFPA does not, by the publication of its codes, standards, recommended practices, and guides, intend to urge action that is not in compliance w

23、ith applicable laws, and these documents may not be construed as doing so. Copyrights NFPA Standards are copyrighted. They are made available for a wide variety of both public and private uses. These include both use, by reference, in laws and regulations, and use in private self-regulation, standar

24、dization, and the promotion of safe practices and methods. By making these documents available for use and adoption by public authorities and private users, the NFPA does not waive any rights in copyright to these documents. Use of NFPA Standards for regulatory purposes should be accomplished throug

25、h adoption by reference. The term “adoption by reference” means the citing of title, edition, and publishing information only. Any deletions, additions, and changes desired by the adopting authority should be noted separately in the adopting instrument. In order to assist NFPA in following the uses

26、made of its documents, adopting authorities are requested to notify the NFPA (Attention: Secretary, Standards Council) in writing of such use. For technical assistance and questions concerning adoption of NFPA Standards, contact NFPA at the address below. For Further Information All questions or oth

27、er communications relating to NFPA Standards and all requests for information on NFPA procedures governing its codes and standards development process, including information on the procedures for requesting Formal Interpretations, for proposing Tentative Interim Amendments, and for proposing revisio

28、ns to NFPA standards during regular revision cycles, should be sent to NFPA headquarters, addressed to the attention of the Secretary, Standards Council, NFPA, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101; email: stds_adminnfpa.org For more information about NFPA, visit the NFPA website

29、 at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/freeaccess.13D-1 NFPA and National Fire Protection Association are registered trademarks of the National Fire Protection Association, Quincy, Massachusetts 02169. Copyright 2015 National Fire Protection Associati

30、on . All Rights Reserved. NFPA 13D Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes 2016 Edition This edition of NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, was prepare

31、d by the Technical Committee on Residential Sprinkler Systems and released by the Correlating Committee on Automatic Sprinkler Systems. It was issued by the Standards Council on May 26, 2015, with an effective date of June 15, 2015, and supersedes all previous editions. This edition of NFPA 13D was

32、approved as an American National Standard on June 15, 2015. Origin and Development of NFPA 13D Recognizing the need to reduce the annual life loss from re in residential occupancies (about 50 percent of total loss of life by re), the Committee on Automatic Sprinklers appointed a subcommittee in May

33、1973 to prepare the Standard on the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Mobile Homes. The subcommittee was composed of members of the Committee on Automatic Sprinklers and other technically competent experts. The standard was submitted and adopted at the NFPA Annua

34、l Meeting in Chicago, Illinois, on May 1216, 1975. The 1980 edition was a complete rewrite of the 1975 edition, including SI units where appropriate. The 1980 edition incorporated the results of the residential sprinkler test program administered by the National Fire Protection Association and funde

35、d by a research grant from the United States Fire Administration. Factory Mutual Research Corporation and the Los Angeles City Fire Department conducted the dwelling tests. Factory Mutual Research Corporation, McNeary Insurance Consulting Services, and the Charlotte, North Carolina, Fire Department

36、conducted the mobile home tests. After gaining practical experience using the 1980 edition, modications to the standard, including removal of design parameters for dry pipe systems, were made in the 1984 edition. The 1989 and 1991 editions established criteria for the use of antifreeze systems as we

37、ll as some of the installation criteria associated with specially listed piping materials. The 1994 edition provided expanded information on nonmetallic pipe and introduced a new design option that reduced water storage requirements for limited area dwellings. The 1996 edition of the standard includ

38、ed expanded information on the use and placement of residential sprinklers near heat sources. For the rst time since 1941, the use of in. (12.7 mm) piping material was permitted again for sprinkler systems under specic conditions. A number of appendix gures were also added to address methods for pro

39、tecting pipe from freezing in unheated attics. The 1999 edition revised criteria for certain types of multipurpose piping systems and added requirements to mitigate the effect of water softeners and lters on system performance. Information on the application of solvent cement for nonmetallic piping

40、systems was provided, and the exception for omitting sprinkler coverage in attics and crawl spaces was modied. The 2002 edition incorporated revisions to update the standard to comply with the 2000 edition of the Manual of Style for NFPA Technical Committee Documents. These revisions included editor

41、ially rewording any exceptions as requirements. The 2002 edition also included changes that established a minimum design discharge density. The requirements for multipurpose systems were changed to require a bypass valve for installations with water softeners or water ltration equipment installedINS

42、TALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO-FAMILY DWELLINGS AND MANUFACTURED HOMES 13D-2 2016 Edition and to update the requirements for network systems. The chapter specically addressing limited area dwelling systems was no longer included in the standard. The 2007 edition included new spacing

43、and obstruction rules addressing sloped ceilings, ceiling pockets, ceiling fans, and kitchen cabinets. Also new to this edition were installation, design, and acceptance requirements for pumps. The acceptability of insulation as a method of freeze protection and the acceptability of wells as a water

44、 source were claried for this edition. New requirements for listed dry pipe/preaction residential sprinkler systems, as well as claried requirements for multipurpose combined and networked sprinkler systems, were incorporated. Finally, specic obstruction rules were added for residential sprinklers.

45、In the 2010 edition new requirements were added for a prescriptive pipe sizing method as an alternative to the hydraulic calculation method. The standard added the term townhouses to the denition of dwelling in order to clarify that townhouses that meet the denition of dwelling can be protected by a

46、n NFPA 13D system. Finally, annex material was added to provide clear guidance for the owner on how to properly inspect, test, and maintain the system. The 2013 edition of NFPA 13D included a restructuring to make the document easier to use. Four new chapters were added, breaking out freeze protecti

47、on, acceptance testing, maintenance, and discharge criteria into their own chapters. This edition has also seen modication to the denitions of multipurpose and stand-alone systems, along with a new denition for passive purge systems. New language addressing the number of heads to be calculated for c

48、ertain sloped and beamed ceiling congurations was added based on a Fire Protection Research Foundation report. The antifreeze requirements were updated through a series of TIAs that were developed based on FPRF testing. Several signicant revisions have been made during the development of the 2016 ed

49、ition. A new gure addresses positioning of sprinklers to avoid obstructions where there are sloped ceilings. Clarication has been added that once a sprinkler is removed from a tting or welded outlet it should not be reinstalled if torque was applied to the sprinkler itself. A new sketch shows an insulation practice using tenting in an attic or concealed space. One of the largest changes to the 2016 edition of NFPA 13D is the review of all metric conversions. Historically the document has used an “exact“ conversion process, but in the 2016 edi