1、 Errata NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents 2013 Edition Reference: Various Errata No.: 1951-13-1 The Technical Committee on Special Operations Protective Clothing and Equipment notes the following errors in the 2013 edition of NFPA 1951, Standard on Protective
2、Ensembles for Technical Rescue Incidents. 1. Delete 8.5.13.13.1 as follows: 8.5.13.13.1 The container shall be filled with tap water to a height within 25 mm (1 in.) of the footwear height as determined in 6.2.4.4. 2. Delete 8.32.4.2 and 8.32.4.3 as follows: 8.32.4.2 A freestanding flame height indi
3、cator shall be used to assist in adjusting the burner flame height. The indicator shall mark a flame height of 75 mm (3 in.) above the top of the burner. 8.32.4.3 A specimen support assembly shall be used to support the footwear specimen above the burner flame. 3. Revise 8.32.5.5 (1) to read as foll
4、ows: 8.32.5.5 (1) The toe shall be at a 7.5 degree, +/1 2.5 degree angle above the heel. Issue Date: May 1, 2013 (Note: Electronic products and pamphlet reprints may have this errata incorporated. For current information about the NFPA Codes and Standards, including this errata, please see www.nfpa.org/codelist) Copyright 2013 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION