NFPA 30B AMD 3-2016 en Code for the Manufacture and Storage of Aerosol Products (Effective Date 4 26 2016).pdf

上传人:fuellot230 文档编号:1008579 上传时间:2019-03-19 格式:PDF 页数:1 大小:30.53KB
下载 相关 举报
NFPA 30B AMD 3-2016 en Code for the Manufacture and Storage of Aerosol Products (Effective Date 4 26 2016).pdf_第1页
第1页 / 共1页
亲,该文档总共1页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Tentative Interim Amendment NFPA30B Code for the Manufacture and Storage of Aerosol Products 2015 Edition Reference: 7.2.1, 7.2.2, 7.2.2.1, 7.2.2.1.1(new), 7.2.2.2 and Table 7.2.3.1 TIA 15-3 (SC 16-4-2 / TIA Log #1198R) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA

2、 Standards, the National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 30B, Code for the Manufacture and Storage of Aerosol Products, 2015 edition. The TIA was processed by the Technical Committee on Aerosol Products, and was issued by the Standards Council

3、 on April 6, 2016, with an effective date of April 26, 2016. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public

4、input of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. Revise sections 7.2.1, 7.2.2, 7.2.2.1, 7.2.2.1.1(new) and 7.2.2.2 to read as follows: 7.2 Sales Display Areas Aerosol Storage Not Exceeding 2.4 m (8 f

5、t) High. 7.2.1 Level 1 aerosol products and plastic aerosol 1 products in sales display areas shall not be limited in quantity. 7.2.2 When located in sales display areas, aerosol cooking spray products and Level 2 and Level 3 aerosol products shall be removed from combustible cartons or the combusti

6、ble cartons shall be display-cut, except as provided for in 7.2.2.1 and 7.2.2.2, respectively. 7.2.2.1 Cartoned aerosol cooking spray products shall be permitted in the sales display area, provided the area is protected in accordance with one of the following: (1) Table 6.3.2.3(a) or Table 6.3.2.3(b

7、), or (2) Paragraph 7.2.3.1. 7.2.2.1.1 Protection in accordance with Table 6.4.2.7(a) through Table 6.4.2.7(l) shall also be permitted for aerosol cooking spray products. 7.2.2.2 Cartoned Level 2 and Level 3 aerosol products shall be permitted in the sales display area, provided the area is protecte

8、d in accordance with one of the following: (1) Table 6.4.2.7(a) through Table 6.4.2.7(l), or (2) Paragraph 7.2.3.1. 2. Revise the title of Table 7.2.3.1 to read as follows: Table 7.2.3.1 Maximum Quantity per Floor of Aerosol Cooking Spray Products, and of Level 2 and Level 3 Aerosol Products Issue Date: April 6, 2016 Effective Date: April 26, 2016 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/codelist) Copyright 2016 All Rights Reserve NATIONAL FIRE PROTECTION ASSOCIATION

展开阅读全文
相关资源
猜你喜欢
  • KS C IEC 61666-2011 Industrial systems installations and equipment and industrial products-Identification of terminals within a system《工业系统、设施、设备和工业产品 系统中端子的识别》.pdf KS C IEC 61666-2011 Industrial systems installations and equipment and industrial products-Identification of terminals within a system《工业系统、设施、设备和工业产品 系统中端子的识别》.pdf
  • KS C IEC 61674-2007 Medical electrical equipment-Dosimeters with ionization chambers and or semi-conductor detectors as used in X-ray diagnostic imaging《医用电气设备 用于X射线诊断成像中带电离室和 或半导体.pdf KS C IEC 61674-2007 Medical electrical equipment-Dosimeters with ionization chambers and or semi-conductor detectors as used in X-ray diagnostic imaging《医用电气设备 用于X射线诊断成像中带电离室和 或半导体.pdf
  • KS C IEC 61675-2-2007 Radionuclide imaging devices-Characteristics and test conditions-Part 2:Single photon emission computed tomographs《放射性核素成像设备 性能和试验条件 第2部分 单光子发射计算断层摄影》.pdf KS C IEC 61675-2-2007 Radionuclide imaging devices-Characteristics and test conditions-Part 2:Single photon emission computed tomographs《放射性核素成像设备 性能和试验条件 第2部分 单光子发射计算断层摄影》.pdf
  • KS C IEC 61689-2005 Ultrasonics-Physiotherapy systems-Performance requirements and methods of measurement in the frequency range 0 5 MHz to 5 MHz《超音波学 物理疗法系统 频率范围0 5MHz~5MHz的现场规范和测.pdf KS C IEC 61689-2005 Ultrasonics-Physiotherapy systems-Performance requirements and methods of measurement in the frequency range 0 5 MHz to 5 MHz《超音波学 物理疗法系统 频率范围0 5MHz~5MHz的现场规范和测.pdf
  • KS C IEC 61724-2012 Photovoltaic system performance monitoring-Guidelines for measurement data exchange and analysis《光伏系统性能监测 测量、数据交换和分析指南》.pdf KS C IEC 61724-2012 Photovoltaic system performance monitoring-Guidelines for measurement data exchange and analysis《光伏系统性能监测 测量、数据交换和分析指南》.pdf
  • KS C IEC 61744-2007 Calibration of fibre optic chromatic dispersion test sets《光纤色散试验装置的校准》.pdf KS C IEC 61744-2007 Calibration of fibre optic chromatic dispersion test sets《光纤色散试验装置的校准》.pdf
  • KS C IEC 61745-2001 End-face image analysis procedure for the calibration of optical fibre geometry test setsthe calibration of optical fibre geometry test sets《光学纤维几何测试组件用端面图形分析结果.pdf KS C IEC 61745-2001 End-face image analysis procedure for the calibration of optical fibre geometry test setsthe calibration of optical fibre geometry test sets《光学纤维几何测试组件用端面图形分析结果.pdf
  • KS C IEC 61747-5-2-2006 Liquid crystal display devices-Part 5-2:Visual inspection of active matrix liquid crystal display modules《液晶显示装置 第5-2部分 环境、耐久性和机械试验方法 有源矩阵彩色液晶显示模块的外观检查》.pdf KS C IEC 61747-5-2-2006 Liquid crystal display devices-Part 5-2:Visual inspection of active matrix liquid crystal display modules《液晶显示装置 第5-2部分 环境、耐久性和机械试验方法 有源矩阵彩色液晶显示模块的外观检查》.pdf
  • KS C IEC 61747-5-3-2007 Liquid crystal display devices-Part 5-3:Glass strength and reliability measurement method《液晶显示装置 第5-3部分 环境、耐久性和机械试验方法 玻璃强度和可靠性》.pdf KS C IEC 61747-5-3-2007 Liquid crystal display devices-Part 5-3:Glass strength and reliability measurement method《液晶显示装置 第5-3部分 环境、耐久性和机械试验方法 玻璃强度和可靠性》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1