1、 Tentative Interim Amendment NFPA70 National Electrical Code2014 Edition Reference: 625.17(B) TIA 14-8 (SC 15-4-5 / TIA Log #1162) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the National Fire Protection Association has issued the following Tentative In
2、terim Amendment to NFPA 70, National Electrical Code, 2014 edition. The TIA was processed by the National Electrical Code Panel 12 and the Correlating Committee on the National Electrical Code, and was issued by the Standards Council on April 7, 2015, with an effective date of April 27, 2015. A Tent
3、ative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public input of the proponent for the next edition of the standard; as suc
4、h, it then is subject to all of the procedures of the standards-making process. 1. Revise Section 625.17(B) to read as follows: (B) Output Cable to the Electric Vehicle. The output cable to the electric vehicle shall be Type EV, EVJ, EVE, EVJE, EVT, or EVJT flexible cable as specified in Table 400.4
5、. The output cable shall have an ampacity as specified in Table 400.5(A)(1) or, for 8 AWG and larger, in the 60C columns of Table 400.5(A)(2). Issue Date: April 7, 2015 Effective Date: April 27, 2015 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/codelist) Copyright 2015 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION