NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf

上传人:amazingpat195 文档编号:1008886 上传时间:2019-03-19 格式:PDF 页数:27 大小:237.33KB
下载 相关 举报
NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf_第1页
第1页 / 共27页
NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf_第2页
第2页 / 共27页
NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf_第3页
第3页 / 共27页
NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf_第4页
第4页 / 共27页
NFPA 99B-2018 Standard for Hypobaric Facilities (Effective Date 08 21 2017).pdf_第5页
第5页 / 共27页
点击查看更多>>
资源描述

1、 NFPA 99B Standard for Hypobaric Facilities 2018IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDS NFPA codes, standards, recommended practices, and guides (“NFPA Standards”), of which the document contained herein is o

2、ne, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on re and other safety issues. While the NFPA administers the process a

3、nd establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards. The NFPA disclaims liability for any personal injury, property, or other damage

4、s of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information published herein. In i

5、ssuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or he

6、r own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of NFPA Standards. Nor does the NFPA l

7、ist, certify, test, or inspect products, designs, or installations for compliance with this document. Any certication or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the responsibility of the certier or maker of the statemen

8、t. REVISION SYMBOLS IDENTIFYING CHANGES FROM THE PREVIOUS EDITION Text revisions are shaded. A before a section number indicates that words within that section were deleted and a to the left of a table or gure number indicates a revision to an existing table or gure. When a chapter was heavily revis

9、ed, the entire chapter is marked throughout with the symbol. Where one or more sections were deleted, a is placed between the remaining sections. Chapters, annexes, sections, gures, and tables that are new are indicated with an N. Note that these indicators are a guide. Rearrangement of sections may

10、 not be captured in the markup, but users can view complete revision details in the First and Second Draft Reports located in the archived revision information section of each code at www.nfpa.org/docinfo. Any subsequent changes from the NFPA Technical Meeting, Tentative Interim Amendments, and Erra

11、ta are also located there. REMINDER: UPDATING OF NFPA STANDARDS Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of a Tentative Interim Amendment (TIA) or corrected by Errata

12、. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any TIAs and Errata then in effect. To determine whether an NFPA Standard has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, go to www.nfpa.org/doci

13、nfo to choose from the list of NFPA Standards or use the search feature to select the NFPA Standard number (e.g., NFPA 13). The document information page provides up-to-date document-specic information as well as postings of all existing TIAs and Errata. It also includes the option to register for a

14、n “Alert” feature to receive an automatic email notication when new updates and other information are posted regarding the document. ISBN: 978-145591681-8 (Print) ISBN: 978-145591682-5 (PDF) ISBN: 978-145591761-7 (eBook)IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA STANDARDS ADDITIONAL NOTICES A

15、ND DISCLAIMERS Updating of NFPA Standards Users of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of Tentative Inte

16、rim Amendments or corrected by Errata. An ofcial NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendments and any Errata then in effect. In order to determine whether a given document is the current edition and whether it has b

17、een amended through the issuance of Tentative Interim Amendments or corrected through the issuance of Errata, consult appropriate NFPA publications such as the National Fire Codes Subscription Service, visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed below. Interpret

18、ations of NFPA Standards A statement, written or oral, that is not processed in accordance with Section 6 of the Regulations Governing the Development of NFPA Standards shall not be considered the ofcial position of NFPA or any of its Committees and shall not be considered to be, nor be relied upon

19、as, a Formal Interpretation. Patents The NFPA does not take any position with respect to the validity of any patent rights referenced in, related to, or asserted in connection with an NFPA Standard. The users of NFPA Standards bear the sole responsibility for determining the validity of any such pat

20、ent rights, as well as the risk of infringement of such rights, and the NFPA disclaims liability for the infringement of any patent resulting from the use of or reliance on NFPA Standards. NFPA adheres to the policy of the American National Standards Institute (ANSI) regarding the inclusion of paten

21、ts in American National Standards (“the ANSI Patent Policy”), and hereby gives the following notice pursuant to that policy: NOTICE: The users attention is called to the possibility that compliance with an NFPA Standard may require use of an invention covered by patent rights. NFPA takes no position

22、 as to the validity of any such patent rights or as to whether such patent rights constitute or include essential patent claims under the ANSI Patent Policy. If, in connection with the ANSI Patent Policy, a patent holder has led a statement of willingness to grant licenses under these rights on reas

23、onable and nondiscriminatory terms and conditions to applicants desiring to obtain such a license, copies of such led statements can be obtained, on request, from NFPA. For further information, contact the NFPA at the address listed below. Law and Regulations Users of NFPA Standards should consult a

24、pplicable federal, state, and local laws and regulations. NFPA does not, by the publication of its codes, standards, recommended practices, and guides, intend to urge action that is not in compliance with applicable laws, and these documents may not be construed as doing so. Copyrights NFPA Standard

25、s are copyrighted. They are made available for a wide variety of both public and private uses. These include both use, by reference, in laws and regulations, and use in private self-regulation, standardization, and the promotion of safe practices and methods. By making these documents available for

26、use and adoption by public authorities and private users, the NFPA does not waive any rights in copyright to these documents. Use of NFPA Standards for regulatory purposes should be accomplished through adoption by reference. The term “adoption by reference” means the citing of title, edition, and p

27、ublishing information only. Any deletions, additions, and changes desired by the adopting authority should be noted separately in the adopting instrument. In order to assist NFPA in following the uses made of its documents, adopting authorities are requested to notify the NFPA (Attention: Secretary,

28、 Standards Council) in writing of such use. For technical assistance and questions concerning adoption of NFPA Standards, contact NFPA at the address below. For Further Information All questions or other communications relating to NFPA Standards and all requests for information on NFPA procedures go

29、verning its codes and standards development process, including information on the procedures for requesting Formal Interpretations, for proposing Tentative Interim Amendments, and for proposing revisions to NFPA standards during regular revision cycles, should be sent to NFPA headquarters, addressed

30、 to the attention of the Secretary, Standards Council, NFPA, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101; email: stds_adminnfpa.org. For more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/docinfo.99

31、B-1 NFPA and National Fire Protection Association are registered trademarks of the National Fire Protection Association, Quincy, Massachusetts 02169. Copyright 2017 National Fire Protection Association . All Rights Reserved. NFPA 99B Standard for Hypobaric Facilities 2018 Edition This edition of NFP

32、A 99B, Standard for Hypobaric Facilities, was prepared by the Technical Committee on Hyperbaric and Hypobaric Facilities and released by the Correlating Committee on Health Care Facilities. It was issued by the Standards Council on August 1, 2017, with an effective date of August 21, 2017, and super

33、sedes all previous editions. This edition of NFPA 99B was approved as an American National Standard on August 21, 2017. Origin and Development of NFPA 99B In 1965, when the Subcommittee on Hyperbaric Facilities was appointed, several hospitals were employing hypobaric therapy to treat respiratory di

34、seases. Additionally, NASA and the U.S. Air Force were working with hypobaric chambers for space and air ight. The name of the subcommittee was then changed to Hyperbaric and Hypobaric Facilities, and the initial version of a document on this subject was prepared. A tentative standard on the subject

35、, NFPA 56E-T, was adopted at the 1971 Annual Meeting. In May 1972, the document was adopted as an ofcial standard. The document was revised again for the 1977 NFPA Annual Meeting. A complete review of NFPA 56E was accomplished for the 1981 Fall Meeting. That edition was designated NFPA 56E-1982. In

36、1984, NFPA 56E was combined with 11 other health care documents to form NFPA 99, Standard for Health Care Facilities. NFPA 56E essentially became Chapter 11 of NFPA 99. In that revision, the major change made to the 1982 edition of NFPA 56E was a complete revision of requirements for Class D chamber

37、s to reect their use for high-altitude training purposes. (Such chambers do not require as extensive safety precautions as research and clinical chambers.) During the revision for the 1987 edition of NFPA 99, it was brought to the attention of the Subcommittee on Hyperbaric and Hypobaric Facilities

38、that hypobaric chambers were no longer used for medical purposes. As such, the material on hypobaric facilities really did not belong in NFPA 99. Thus, the subcommittee proposed that this material be separated from NFPA 99 and again published as a distinct NFPA document. It was designated NFPA 99B.

39、Minor revisions were made to editions adopted in 1987 and 1990. For the 1993 edition of Standard for Hypobaric Facilities, the one signicant change was the identication of the safety director as the person responsible for disseminating information on hazards associated with operating hypobaric facil

40、ities. For the 1996 edition, the major changes included clarifying the application of the document (Chapters 14) and deleting a Class Ftype chamber because the committee was unaware of hypobaric techniques involving articial atmospheres. The 1999 edition modied several paragraphs to conform to the M

41、anual of Style for NFPA Technical Committee Documents for enforceable language. Other changes were editorial in nature. The 2002 edition included format revisions. The Manual of Style for NFPA Technical Committee Documents was applied in this documents restructure and format. Introductory material i

42、n Chapter 1 was formatted for consistency among all NFPA documents. Referenced publications that applied to the document were relocated to Chapter 2, resulting in the renumbering of chapters. Informational references remained in the last annex. Appendices were designated as annexes. Denitions in Cha

43、pter 3 were reviewed for consistency with denitions in other NFPA documents, were systematically aligned, and were individually numbered. Paragraph structuring was revised with the intent of having one mandatory requirement per section, subsection, or paragraph. Information thatHYPOBARIC FACILITIES

44、99B-2 2018 Edition often accompanied many of the requirements was moved to Annex A. Exceptions were deleted or rephrased in mandatory text, unless the exception represented an allowance or required alternate procedure to a general rule when limited specied conditions existed. The revised format appe

45、arance and structure provided continuity among NFPA documents, clarity of mandatory text, and greater ease in locating specic mandatory text. The 2005 edition was slightly modied to clarify some requirements. The ventilation rate was specied by the purchaser, detection in Class D chambers was made o

46、ptional, the wiring method in Class E chambers was downgraded, aviation-type masks in chambers were made optional, the hazards of titanium were discussed, and ttings were listed for oxygen service. The 2010 edition of the standard made minor changes in denitions to correlate with other denitions fro

47、m the Glossary of Terms. The 2015 edition of the standard was revised to update the referenced standards to the most current editions available and to correct several references to NFPA 99 to match the 2015 edition of that code. The 2018 edition of the standard was revised to update the referenced s

48、tandards to the most current editions available. It also changed language throughout the standard to better align with NFPA 99, specically in regards to interior paint/coating and ooring for Class D and E chambers and changing the wording “ame resistant (hypobaric)” to “limited-combustible (material

49、).”COMMITTEE PERSONNEL 99B-3 2018 Edition Correlating Committee on Health Care Facilities Michael A. Crowley, Chair JENSEN HUGHES, TX SE Chad E. Beebe, ASHE - AHA, WA U Constance Bobik, B b) from re and explosion hazards; c) in connection with the use of hyperbaric and hypobaric facilities for medical purposes; d) through performance, maintenance and testing criteria for electrical systems, both normal and essential; and e) through performance, maintenance and testing, and installation criteria: (1) for vacuum systems for medical or s

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1