1、*USACE / NAVFAC / AFCESA / NASA UFGS-28 31 13.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-28 31 13.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*SECTION TABLE OF CONTENTSDIVISION 28 - ELECTRONIC SAFETY AND SECURITYSECTI

2、ON 28 31 13.00 40FIRE DETECTION AND ALARM CONTROL, GUI, AND LOGIC SYSTEMS05/13PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DESCRIPTION OF WORK1.3.1 Scope1.4 GENERAL REQUIREMENTS1.4.1 Nameplates1.4.2 Tags1.4.3 Verification of Dimensions1.4.4 Compliance1.4.5 Qualifications1.4.5.1 Engineer and Technic

3、ian1.4.5.2 Design Services1.4.5.3 Qualifications of Installer1.4.6 Detail Drawings1.5 RELATED REQUIREMENTS1.5.1 Basic Electrical Materials And Methods1.5.2 Predictive Testing And Inspection Technology Requirements1.6 QUALITY ASSURANCE1.6.1 Regulatory Requirements1.6.1.1 Requirements for Fire Protect

4、ion Service1.6.1.2 Testing Services or Laboratories1.6.2 Standard Products1.6.3 Modification of References1.7 SPARE PARTS AND TOOLS1.7.1 Interchangeable Parts1.7.2 Spare Parts1.7.3 Parts List1.8 KEYS1.9 SYSTEM DESIGN1.9.1 Operation1.9.2 Operational Features1.9.3 Alarm Functions1.9.4 Primary Power1.9

5、.5 Battery Backup PowerSECTION 28 31 13.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.9.6 Interface With Existing Fire Alarm Equipment1.9.7 Interface With Other Equipment1.10 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 EXISTING

6、FIRE ALARM EQUIPMENT2.1.1 Equipment Removal2.1.2 Repair Service/Replacement Parts2.1.3 Other Divisions To Be Coordinated With2.1.4 Manufacturer Qualifications2.2 INTERIOR FIRE ALARM SYSTEM DESIGN2.2.1 Definitions2.2.2 System Operation2.2.3 System Monitoring2.2.3.1 Valves2.2.3.2 Independent Fire Dete

7、ction System2.2.4 Overvoltage and Surge Protection2.2.4.1 Signaling Line Circuit Surge Protection2.2.4.2 Sensor Wiring Surge Protection2.2.5 Addressable Interface Devices2.2.6 Smoke Sensors2.2.6.1 Photoelectric Smoke Sensors2.2.6.2 Ionization Type Smoke Sensors2.2.6.3 Duct Smoke Sensors2.2.6.4 Smoke

8、 Sensor Testing2.2.6.5 Projected Beam Smoke Detectors2.2.7 Thermal Sensors2.2.8 Electric Power2.2.8.1 Primary Power2.2.8.2 Generator2.2.9 Emergency Power Supply2.2.9.1 Batteries2.2.9.2 Capacity2.2.9.3 Battery Chargers2.2.10 System Field Wiring2.2.10.1 Wiring Within Cabinets, Enclosures, Boxes, Junct

9、ion Boxes, and Fittings2.2.10.2 Terminal Cabinets2.2.10.3 Alarm Wiring2.2.10.4 Conductor Terminations2.2.10.5 Wiring to Station Telegraphic Fire Alarm Circuit2.2.11 Fire Alarm Control Panel (FACP)2.2.11.1 Cabinet2.2.11.2 Control Modules2.2.11.3 Silencing Switches2.2.11.4 Non-Interfering2.2.11.5 Fire

10、 Alarm Voice Message2.2.11.6 Fire Alarm Signal2.2.11.7 Memory2.2.11.8 Field Programmability2.2.11.9 Input/Output Modifications2.2.11.10 Resetting2.2.11.11 Instructions2.2.11.12 Walk Test2.2.11.13 History Logging2.2.11.14 RS-232-C Output2.2.12 Remote Fire Alarm Control Units2.2.12.1 CabinetSECTION 28

11、 31 13.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2.12.2 Control Modules2.2.12.3 Silencing Switches2.2.12.4 Non-Interfering2.2.12.5 Memory2.2.12.6 Field Programmability2.2.12.7 Input/Output Modifications2.2.12.8 Resetting2.2.12.9 I

12、nstructions2.2.12.10 Walk Test2.2.12.11 History Logging2.2.13 Amplifiers, Preamplifiers, Tone Generators2.2.13.1 Construction2.2.13.2 Inputs2.2.13.3 Tone Generator2.2.13.4 Protection Circuits2.2.14 Video Display Unit (VDU)2.2.15 Graphic Annunciator2.2.15.1 Annunciator Panel2.2.15.2 Indicating Lights

13、2.2.15.3 Material2.2.15.4 Programming2.2.16 System Printers2.2.17 Firefighter Telephone Communication System2.2.18 Manual Stations2.2.19 Notification Appliances2.2.19.1 Fire Alarm Speakers2.2.19.2 Visual Alarm Signals2.2.19.3 Fire Alarm Horns2.2.19.4 Fire Alarm Bells2.2.19.5 Connections2.2.19.6 Chim

14、es2.2.19.7 Combination Audible/Visual Notification Appliances2.2.19.8 Voice Evacuation System2.2.20 Valve Monitor Switches (Tamper Switches)2.2.21 Waterflow Detectors2.2.22 Electromagnetic Door Holders2.2.23 Automatic Transmitters2.2.23.1 Telegraphic Transmitter2.2.23.2 Radio Transmitter and Interfa

15、ce Panels2.2.23.3 Digital Alarm Communicator Transmitter (DACT)2.2.23.4 Signals To Be Transmitted To The Base Receiving Station2.3 NAMEPLATES2.4 WIRING2.5 CONTROL PANEL2.5.1 Remote System Audible/Visual Display2.5.2 Circuit Connections2.5.3 System Expansion and Modification Capabilities2.5.4 Address

16、able Control Module2.5.5 Addressable Initiating Device Circuits Module2.6 STORAGE BATTERIES2.6.1 Battery Power Calculations2.6.1.1 Low Battery Voltage2.7 ADDRESSABLE MANUAL FIRE ALARM STATIONS2.8 FIRE DETECTING DEVICES2.8.1 Heat Detectors2.8.1.1 Combination Fixed-Temperature and Rate-of-Rise Detecto

17、rs2.8.1.2 Rate Compensating Detectors2.8.1.3 Fixed Temperature Detectors2.8.2 Combination Smoke and Heat DetectorsSECTION 28 31 13.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.8.3 Flame Detectors2.8.3.1 Infrared (IR) Single Frequency

18、 Flame Detector2.8.3.2 Infrared (IR) Dual Frequency Flame Detector2.8.3.3 Ultraviolet (UV) Flame Detectors2.8.3.4 Combination UV/IR Flame Detector2.9 FIRE DETECTION AND ALARM SYSTEM PERIPHERAL EQUIPMENT2.9.1 Conduit2.9.2 Wiring2.9.3 Special Tools and Spare Parts2.10 TRANSMITTERS2.10.1 Radio Alarm Tr

19、ansmitters2.10.1.1 Transmitter Power Supply2.10.1.2 Radio Alarm Transmitter Housing2.10.1.3 Antenna2.10.2 Master Fire Alarm Boxes2.10.3 Telephonic Reporting SystemPART 3 EXECUTION3.1 INSTALLATION OF FIRE ALARM INITIATING AND INDICATING DEVICES3.1.1 Power Supply for the System3.1.2 Wiring3.1.3 Contro

20、l Panel3.1.4 Detectors3.1.5 Notification Appliances3.1.6 Annunciator Equipment3.1.7 Addressable Initiating Device Circuits Module3.1.8 Addressable Control Module3.2 DISCONNECTION AND REMOVAL OF EXISTING SYSTEM3.3 CONNECTION OF NEW SYSTEM3.4 FIRESTOPPING3.5 PAINTING3.6 FIELD QUALITY CONTROL3.6.1 Test

21、s3.6.2 Minimum System Tests3.7 OVERVOLTAGE AND SURGE PROTECTION3.7.1 Power Line Surge Protection3.7.2 Low Voltage DC Circuits Surge Protection3.7.3 Signal Line Circuit Surge Protection3.8 GROUNDING3.9 SUPERVISING STATION PROVISIONS3.9.1 Revisions to Existing Facilities3.9.2 Additions to Existing Fac

22、ilities3.10 TESTING3.10.1 Preliminary Tests3.10.2 Acceptance Test3.11 TRAINING3.11.1 Instruction Of Government Employees3.11.1.1 Instructor3.11.1.2 Qualifications3.11.1.3 Required Instruction Time3.11.2 Training- End of Section Table of Contents -SECTION 28 31 13.00 40 Page 4Provided by IHSNot for R

23、esaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-28 31 13.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-28 31 13.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*

24、SECTION 28 31 13.00 40FIRE DETECTION AND ALARM CONTROL, GUI, AND LOGIC SYSTEMS05/13*NOTE: This guide specification covers the requirements for analog/ addressable interior fire alarm systems in single or multiple buildings, requirements for fire detection and alarm systems, and addressable systems.A

25、dhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choo

26、se applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Req

27、uest (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Refer

28、ence Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update SECTION 28 31 13.00 40 Page 5Provided by IHSNot for ResaleNo reproduction

29、or networking permitted without license from IHS-,-,-the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this sp

30、ecification to the extent referenced. The publications are referred to within the text by the basic designation only.ACOUSTICAL SOCIETY OF AMERICA (ASA)ASA S3.41 (1990; R 2008) Audible Emergency Evacuation Signal (ASA 96)ASME INTERNATIONAL (ASME)ASME A17.1/CSA B44 (2010) Safety Code for Elevators an

31、d EscalatorsFM GLOBAL (FM)FM APP GUIDE (updated on-line) Approval Guide http:/ OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)IEEE C62.41 (1991; R 1995) Recommended Practice on Surge Voltages in Low-Voltage AC Power CircuitsIEEE C62.41.1 (2002; R 2008) Guide on the Surges Environment in Low-Voltage (

32、1000 V and Less) AC Power CircuitsIEEE C62.41.2 (2002) Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and Less) AC Power CircuitsNATIONAL AERONAUTICS AND SPACE ADMINISTRATION (NASA)RCBEA GUIDE (2004) NASA Reliability Centered Building and Equipment Acceptance GuideNATIONAL

33、 FIRE PROTECTION ASSOCIATION (NFPA)NFPA 101 (2012; Amendment 1 2012) Life Safety CodeNFPA 1221 (2013) Standard for the Installation, Maintenance and Use of Emergency Services Communications SystemsNFPA 241 (2013) Standard for Safeguarding Construction,Alteration, and Demolition OperationsNFPA 70 (20

34、11; Errata 2 2012) National Electrical SECTION 28 31 13.00 40 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-CodeNFPA 72 (2013) National Fire Alarm and Signaling CodeNFPA 90A (2012) Standard for the Installation of Air Conditioning and Ventila

35、ting SystemsU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)47 CFR 15 Radio Frequency Devices47 CFR 90 Private Land Mobile Radio ServicesUNDERWRITERS LABORATORIES (UL)UL 1242 (2006; Reprint Jul 2012) Standard for Electrical Intermediate Metal Conduit - SteelUL 1971 (2002; Reprint Oct 2008) S

36、ignaling Devices for the Hearing ImpairedUL 228 (2006; Reprint Nov 2008) Door Closers-Holders, With or Without Integral Smoke DetectorsUL 268 (2009) Smoke Detectors for Fire Alarm SystemsUL 268A (2008; Reprint Sep 2009) Smoke Detectors for Duct ApplicationUL 38 (2008; Reprint Dec 2008) Manual Signal

37、ing Boxes for Fire Alarm SystemsUL 464 (2009; Reprint Apr 2012) Standard for Audible Signal AppliancesUL 521 (1999; Reprint May 2010) Heat Detectors for Fire Protective Signaling SystemsUL 6 (2007; reprint Nov 2010) Electrical Rigid Metal Conduit-SteelUL 632 (2000) Standard for Electrically-Actuated

38、 TransmittersUL 797 (2007; Reprint Dec 2012) Electrical Metallic Tubing - SteelUL 864 (2003; Reprint Aug 2012) Standard for Control Units and Accessories for Fire Alarm SystemsUL Electrical Constructn (2012) Electrical Construction Equipment DirectoryUL Fire Prot Dir (2012) Fire Protection Equipment

39、 DirectorySECTION 28 31 13.00 40 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submitt

40、als required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is

41、 not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags ma

42、y be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ f

43、or Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for sub

44、mittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance

45、 with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsBattery Power Calculations; G; G, _Detail Drawings; G; G, _SD-03 Product DataFire Alarm Control Panel (FACP); G; G, _Printers,; G; G, _Video display unit (VDU); G; G, _Terminal Cabinets; G; G, _SECTION 28 31 13.00 40 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Manual Stations; G; G, _Transmitters; G; G, _