1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AMS2816W AEROSPACE MATERIAL SPECIFICATION AMS2816 REV. W Issued 1963-01 Revised 2
5、008-06 Reaffirmed 2013-10 Superseding AMS2816V Identification Welding Wire, Tab Marking Method RATIONALE AMS2816W has been reaffirmed to comply with the SAE five-year review policy. 1. SCOPE This specification covers procedures for tab marking of bare welding wire to provide positive identification
6、of cut lengths and spools. 2. APPLICABLE DOCUMENTS The issue of the following documents in effect on the date of the purchase order forms a part of this specification to the extent specified herein. The supplier may work to a subsequent revision of a document unless a specific document issue is spec
7、ified. When the referenced document has been cancelled and no superseding document has been specified, the last published issue of that document shall apply. 2.1 SAE Publication Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Can
8、ada) or 724-776-4970 (outside USA), www.sae.org. AS478 Identification Marking Methods 3. TECHNICAL REQUIREMENTS 3.1 Cut Lengths All envelopes shall be marked in accordance with 3.1.1. Individual cut lengths shall be tab marked in accordance with 3.1.2, unless purchaser specifies specification number
9、 marking in accordance with 3.1.3 or provides other requirements for marking. SAE INTERNATIONAL AMS2816W Page 2 of 3 3.1.1 Envelope Marking All envelopes shall be identified with a pressure sensitive label marked with not less than the following information: (Alloy name) WELDING WIRE WIRE SPECIFICAT
10、ION NUMBER SIZE QUANTITY OR WEIGHT HEAT NUMBER (If Applicable) MANUFACTURERS IDENTIFICATION 3.1.1.1 Bar Code Marking When specified, all required identification shall be bar code marked on envelopes or unit containers by a method acceptable to purchaser. 3.1.2 Tab Marking Each length of wire shall h
11、ave applied, between 1/2 to 1 inch (12.7 to 25 mm) from one end, a plastic label bearing the specification number, including type, class and/or grade designation, and the prefix indicating the source of the specification. When wire is ordered to an AMS specification in conjunction with other specifi
12、cations, the wire may be solely identified with the AMS specification. Revision letters are not necessary. The label may be either pressure-sensitive adhesive type or heat-shrinkable tubing in accordance with AS478. Imprints on the label shall be legible, fade-proof, and resistant to oils, solvents,
13、 shipping hazards, and temperatures up to 120 F (49 C). 3.1.3 Specification Number Marking When specified in lieu of 3.1.2 tab marking, each length of wire shall be marked, by a method specified by purchaser in accordance with AS478, with the specification number, including type, class and/or grade
14、of designation, and the prefix indicating the source of the specification. When wire is ordered to an AMS specification in conjunction with other specifications, the wire may be solely identified with the AMS specification. Revision letters are not necessary. The marking method used shall be fade-pr
15、oof and resistant to oils, solvents, shipping hazards, and temperatures up to 120 F (49 C). 3.2 Spooled Wire Wire shall not be marked but the outer face of one or both flanges of each spool shall be permanently and legibly marked with a pressure sensitive label including not less than the following
16、information; if only one flange of each spool is marked, the marking shall be on the flange of the spool which will face the operator when the spool is installed on a welding machine and removed in a clockwise fashion. (Alloy Name) WELDING WIRE WIRE SPECIFICATION NUMBER SIZE QUANTITY OR WEIGHT HEAT
17、NUMBER (If Applicable) MANUFACTURERS IDENTIFICATION 3.2.1 When specified, all required identification may be bar coded on envelopes or unit containers by a method acceptable to purchaser. 4. QUALITY ASSURANCE PROVISIONS Not applicable. SAE INTERNATIONAL AMS2816W Page 3 of 3 5. PREPARATION FOR DELIVE
18、RY Not applicable. 6. ACKNOWLEDGMENT A vendor shall mention this specification number and its revision letter in all quotations and when acknowledging purchase orders. 7. REJECTIONS Wire not identified in accordance with this specification, or with modifications authorized by purchaser, will be subj
19、ect to rejection. 8. NOTES 8.1 A change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this specification. An (R) symbol to the left of the document title indicates a co
20、mplete revision of the specification, including technical revisions. Change bars and (R) are not used in original publications, nor in specifications that contain editorial changes only. 8.2 Tab marking is commonly referred to as flag tagging. 8.3 Terms used in AMS are clarified in ARP1917. 8.4 Dimensions and properties in inch/pound units and the Fahrenheit temperatures are primary; dimensions and properties in SI units and the Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information. PREPARED BY AMS COMMITTEE “B“