SAE AMS 3813 3A-1987 Rope Aramid Fiber Jacketed Parallel Yarn Braided Jacket《编织护套、平行纱线、套式、芳族聚酰胺纤维绳索》.pdf

上传人:twoload295 文档编号:1021178 上传时间:2019-03-21 格式:PDF 页数:4 大小:20.67KB
下载 相关 举报
SAE AMS 3813 3A-1987 Rope Aramid Fiber Jacketed Parallel Yarn Braided Jacket《编织护套、平行纱线、套式、芳族聚酰胺纤维绳索》.pdf_第1页
第1页 / 共4页
SAE AMS 3813 3A-1987 Rope Aramid Fiber Jacketed Parallel Yarn Braided Jacket《编织护套、平行纱线、套式、芳族聚酰胺纤维绳索》.pdf_第2页
第2页 / 共4页
SAE AMS 3813 3A-1987 Rope Aramid Fiber Jacketed Parallel Yarn Braided Jacket《编织护套、平行纱线、套式、芳族聚酰胺纤维绳索》.pdf_第3页
第3页 / 共4页
SAE AMS 3813 3A-1987 Rope Aramid Fiber Jacketed Parallel Yarn Braided Jacket《编织护套、平行纱线、套式、芳族聚酰胺纤维绳索》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、SAE-AMS3813/3ADOPTION NOTICESAE-AMS3813/3, “ROPE, ARAMID FIBER, JACKETED PARALLEL YARN,BRAIDED JACKET“, was adopted on 14-AUG-95 for use by theDepartment of Defense (DoD). Proposed changes by DoDactivities must be submitted to the DoD Adopting Activity:Commander, Defense Supply Center Philadelphia,

2、ATTN: DSCP-ITAA,700 Robbins Avenue, Philadelphia, PA 19111-5096. Copies of thisdocument may be purchased from the Society of AutomotiveEngineers 400 Commonwealth Drive Warrendale, Pennsylvania, UnitedStates, 15096-0001. http:/www.sae.org/_Custodians: Adopting Activity:DLA - ISArmy - GLNavy - SHAir F

3、orce - 99DLA - ISFSC 4020DISTRIBUTION STATEMENT A: Approved for public release; distributionis unlimited.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE Technical Standards Board Rules provide that

4、: “This report is published by SAE to advance the state of technical and enginee ring sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.”SAE

5、reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invit es your written comments and suggestions.Copyright 1998 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.QUESTIONS REGARDING THIS DOCUMENT: (724) 772

6、-7161 FAX: (724) 776-0243TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS: http:/www.sae.org400 Commonwealth Drive, Warrendale, PA 15096-0001AEROS PACE MATERIAL SPECIFIC ATIONSubmitted for recognition as an American National StandardAMS 3813/3AIssued APR 1978Revised JUL 1

7、987Reaffirmed SEP 1998Superseding AMS 3813/3Rope, Aramid Fiber, JacketedParallel Strand, Braided Jacket1. SCOPE:1.1 Form: This specification covers parallel-yarn ropes formed from impregnated aramid fibers.1.2 Application: Primarily for nonconductive tension elements in antenna-supports.1.3 Classifi

8、cation: The ropes are classified by size, based on the nominal diameter of the finished rope as shown in Table I.2. APPLICABLE DOCUMENTS: See AMS 3813.3. TECHNICAL REQUIREMENTS: 3.1 Basic Specification: The complete requirements for procuring the ropes described herein shall consist of this document

9、 and the latest issue of the basic specification, AMS 3813.3.2 Material and Construction: The rope shall consist of aramid fiber constructional yarns gathered together in a parallel arrangement without twist, and covered with a braided jacket. The yarns shall be impregnated with an elastomeric formu

10、lation, filling the interstices between the yarns and between the yarns and the jacket so that the yarns are flexibly bonded to each other and to the jacket.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IH

11、S-,-AMS 3813/3A SAE AMS 3813/3A- 2 -3.2.1 Constructional Yarn: Each single yarn shall conform to AMS 3904/5 and shall be free of splices.3.2.2 Elastomeric Formulation: Shall be chloroprene rubber, applied so that each constructional yarn is heavily coated.3.2.3 Jacket: Shall be a braided polyester j

12、acket, bonded to the rope with a flexible, impervious layer of chloroprene rubber.3.2.4 Rope Size: Shall be designated by the finished nominal diameter as shown in Table I.3.3 Properties: Shall be as specified in Table I and as follows; the properties of ropes having sizes other than those listed in

13、 Table I shall be as agreed upon by purchaser and vendor.3.3.1 Breaking Strength: Shall be as specified in Table I.3.3.2 Linear Density: Shall be within 10% of the value determined during preproduction testing. Nominal values are shown in Table I.3.3.3 Weatherability: The breaking strength, after ex

14、posure to accelerated weathering conditions, shall be not less than 95% of the value specified in Table I.3.3.4 Vibration Fatigue: The breaking strength, after exposure to simulated aeolian vibration conditions, shall be not less than 95% of the value specified in Table I.3.3.5 Flashover Voltage: Sh

15、all be not less than 165 kilovolts.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-AMS 3813/3A SAE AMS 3813/3A- 3 -4. QUALITY ASSURANCE PROVISIONS: See AMS 3813.5. PREPARATION FOR DELIVERY: See AMS 381

16、3.6. ACKNOWLEDGMENT: See AMS 3813.7. REJECTIONS: See AMS 3813.8. NOTES: See AMS 3813.TABLE INominal SizeBreaking StrengthminLinear DensityNominalInch Millimetres lbf kNlb per1000 ft g/m3/8 9.5 9,000 40 55 807/16 11.0 12,000 55 75 1101/2 12.5 18,000 80 97 1455/8 16.0 28,800 130 152 2253/4 19.0 41,500

17、 185 219 3257/8 22.0 56,000 250 298 4451 25.0 74,000 330 389 5801-1/8 28.5 93,500 415 492 7301-1/4 32.0 115,000 510 608 9051-3/8 35.0 140,000 625 735 10951-1/2 37.5 166,000 740 875 13001-5/8 41.0 194,000 865 1027 15301-3/4 44.0 225,000 1000 1191 17702 50.0 295,000 1310 1556 2315Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-

展开阅读全文
相关资源
猜你喜欢
  • ETSI TS 103 161-10-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 10 Management Information Base _1.pdf ETSI TS 103 161-10-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 10 Management Information Base _1.pdf
  • ETSI TS 103 161-11-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 11 Media terminal adapter (MTA).pdf ETSI TS 103 161-11-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 11 Media terminal adapter (MTA).pdf
  • ETSI TS 103 161-11-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 11 Media terminal adapter (MTA)_1.pdf ETSI TS 103 161-11-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 11 Media terminal adapter (MTA)_1.pdf
  • ETSI TS 103 161-12-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 12 Management Event Mechanism (.pdf ETSI TS 103 161-12-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 12 Management Event Mechanism (.pdf
  • ETSI TS 103 161-12-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 12 Management Event Mechanism (_1.pdf ETSI TS 103 161-12-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 12 Management Event Mechanism (_1.pdf
  • ETSI TS 103 161-13-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 13 Trunking Gateway Control Pro.pdf ETSI TS 103 161-13-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 13 Trunking Gateway Control Pro.pdf
  • ETSI TS 103 161-13-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 13 Trunking Gateway Control Pro_1.pdf ETSI TS 103 161-13-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 13 Trunking Gateway Control Pro_1.pdf
  • ETSI TS 103 161-14-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 14 Embedded MTA Analog Interfac.pdf ETSI TS 103 161-14-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 14 Embedded MTA Analog Interfac.pdf
  • ETSI TS 103 161-14-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 14 Embedded MTA Analog Interfac_1.pdf ETSI TS 103 161-14-2011 Access Terminals Transmission and Multiplexing (ATTM) Integrated Broadband Cable and Television Networks IPCablecom 1 5 Part 14 Embedded MTA Analog Interfac_1.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1