1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2012 SAE InternationalAll rights reserved. No part of this publication may b
3、e reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (outside USA)Fax
4、: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/AMSDTL23053/10AAEROSPACEMATERIALSPECIFICATIONAMS-DTL-23053/10REV. AIssued 1999-07Revised 2012-08Supersedi
5、ng AMS-DTL-23053/10Insulation Sleeving, Electrical, Heat Shrinkable,Silicone Rubber, FlexibleFSC 5970RATIONALERevise to include comments received by the government and industry, update references, align specification with SAE guidelines, and review specification for known technical problemsThe requi
6、rements for acquiring the sleeving described herein shall consist of this specification sheet and the issue of the following specification listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicitation: MIL-DTL-23053.REQUIREMENTS:Polyme
7、r type: The base elastomer used in formulating this sleeving shall be a silicone.Continuous operating temperature range: -103 F (-75 C) to +347 F (+175 C).Color: The sleeving shall be furnished in a black color that conforms to the requirements of Class II of MIL-STD-104. (See 1.2.1)Longitudinal cha
8、nge: +3, -10 percentSAE AMS-DTL-23053/10A Page 2 of 4Military part number: The Military part number shall consist of the basic number of this specification sheet and dash numbers shown as follows:M23053/10 - X X - XExample: Black, 2.000 inch (50.80 mm) as supplied ID sleeving shall be identified as
9、M23053/10-012-0.TABLE 1 - CONSTRUCTION DETAILS, INCHES (MM) 1/Militarypart number 3/As suppliedID minimumAfter unrestricted shrinkageID maximum Wall Thickness 2/M23053/10-001-0M23053/10-002-0M23053/10-003-0M23053/10-004-0M23053/10-005-0M23053/10-006-0M23053/10-007-0M23053/10-008-0M23053/10-009-0M230
10、53/10-010-0M23053/10-011-0M23053/10-012-00.125(3.18)0.250(6.35)0.375(9.53)0.500(12.70)0.625(15.88)0.750 (19.05)0.875(22.23)1.000(25.40)1.250(31.75)1.500(38.10)1.750(44.45)2.000(50.80)0.071(1.80)0.143(3.63)0.214(5.44)0.286(7.27)0.357(9.07)0.428(10.87)0.500(12.70)0.570(14.48)0.714(18.14)0.857(21.77)1.
11、000(25.40)1.140(28.96)0.020 0.006 (0.508 0.152)0.035 0.010 (0.889 0.254)0.040 0.010 (1.016 0.254)0.048 0.015 (1.219 0.381)0.052 0.015 (1.321 0.381)0.057 0.015 (1.448 0.381)0.065 0.015 (1.651 0.381)0.070 0.020 (1.778 0.508)0.087 0.020 (2.210 0.508)0.095 0.020 (2.413 0.508)0.107 0.020 (2.718 0.508)0.1
12、10 + 0.020 (2.794 + 0.508)1/ Diameter limits for the object to be enclosed shall be as recommended in technical data.2/ Wall thickness values are less when shrinkage is restricted.3/ The color code identified is the standard color.Unrestricted shrinkage: Test method 4.6.5.2 392 F 4 (200 C 2) for 10
13、minutes.Color code designator (See 1.2.1)Size identifier (See Table 1)Class (Where no classes are specified in thespecification sheet, the numeric “0” is used)Specification sheetSAE AMS-DTL-23053/10A Page 3 of 4TABLE 2 PHYSICAL PROPERTIESCharacteristic Requirement Test procedure and conditionAs supp
14、lied:ID, minimum Table 1 4.6.3.1.1Heat shock No cracks, flowing or dripping 4.6.8 572 F 7.2 (300 C 4) No mandrel bendTensile stress at 100 percent, psi (MPa), maximum1000(6.9) 4.6.12.2 ASTM D 412Cold impact No cracking 4.6.7.2 -105 F 4(-75 C 2)longitudinal strip. ASTM D 746Dielectric strength, volts
15、/mil (Kv/mm), minimum200(7.9) 4.6.2 ASTM D 2671Restricted shrinkage No cracks 4.6.6 392 F 4 (200 C 2)Voltage withstand Pass 4.6.6.3After unrestricted shrinkage:ID, maximum Table 1 4.6.3.1.2Wall thickness Table 1 4.6.3.2Tensile strength, psi (MPa), minimum600(4.2) 4.6.13 ASTM D 638, 20 inches/minuteU
16、ltimate elongation, percent, minimum200 4.6.13 ASTM D 638, 20 inches/minuteVolume resistivity, Ohm-cm, minimum1 x 10114.6.2 ASTM D 876Water absorption, Percent, maximum1.0 4.6.2 ASTM D 570, 24 hrs at 23 CCorrosion No corrosion or pitting 4.6.10.1 and 4.6.10.2,347 F 4 (175 C 2),16 hoursHeat resistanc
17、e, properties after:4.6.9 392 F 4 (200 C 3), 168 hoursTensile strength, psi (MPa), minimum450(3.1)Ultimate elongation,percent, minimum100SAE AMS-DTL-23053/10A Page 4 of 4TABLE 2 PHYSICAL PROPERTIES (CONT.)Characteristic Requirement Test procedure and conditionFluid resistance,properties after:4.6.11
18、Tensile strength,psi (MPa), minimum300 (2.1)Ultimate elongation,percent, minimum100Flammability Self-extinguishing, 1 minute, 25 percent maximum of indicator flagburned4.6.14 Procedure B,ASTM D 2671Fungus resistance properties after:Tensile Strength, psi (MPa), minimumUltimate elongation, percent, m
19、inimumDielectric strength, volts/mil (Kv/mm), minimumNo Growthor600 (4.2)200200 (7.9)4.6.2 ASTM G 214.6.17Storage life conditions: Supplier shall certify to storage at 65 to 95 F (18 to 35 C) for one year. Conformance to 3.5. See 3.5.2 for storage life extension.Intended use: Heat shrinkable, flexib
20、le, silicone sleeving is intended for use in high or low temperature applications or in ablative applications.NOTESA change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue o
21、f this document. An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (R) are not used in original publications, nor in documents that contain editorial changes only.Dimensions and properties in inch/pound units and the Fahrenheit temperatures are primary: dimensions and properties in SI units and the Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information.PREPARED BY AE-8D WIRE AND CABLE COMMITTEE