SAE AMS-DTL-23053 15A-2012 Insulation Sleeving Electrical Heat Shrinkable Polyolefin Heavy-Wall Coated Flexible Outer Wall Crosslinked《外墙交联弹性涂层厚壁聚烯烃热收缩性电气绝缘套管》.pdf

上传人:dealItalian200 文档编号:1022618 上传时间:2019-03-21 格式:PDF 页数:4 大小:51.47KB
下载 相关 举报
SAE AMS-DTL-23053 15A-2012 Insulation Sleeving Electrical Heat Shrinkable Polyolefin Heavy-Wall Coated Flexible Outer Wall Crosslinked《外墙交联弹性涂层厚壁聚烯烃热收缩性电气绝缘套管》.pdf_第1页
第1页 / 共4页
SAE AMS-DTL-23053 15A-2012 Insulation Sleeving Electrical Heat Shrinkable Polyolefin Heavy-Wall Coated Flexible Outer Wall Crosslinked《外墙交联弹性涂层厚壁聚烯烃热收缩性电气绝缘套管》.pdf_第2页
第2页 / 共4页
SAE AMS-DTL-23053 15A-2012 Insulation Sleeving Electrical Heat Shrinkable Polyolefin Heavy-Wall Coated Flexible Outer Wall Crosslinked《外墙交联弹性涂层厚壁聚烯烃热收缩性电气绝缘套管》.pdf_第3页
第3页 / 共4页
SAE AMS-DTL-23053 15A-2012 Insulation Sleeving Electrical Heat Shrinkable Polyolefin Heavy-Wall Coated Flexible Outer Wall Crosslinked《外墙交联弹性涂层厚壁聚烯烃热收缩性电气绝缘套管》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref

2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2012 SAE InternationalAll rights reserved. No part of this publication may b

3、e reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (outside USA)Fax

4、: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/AMSDTL23053/15AAEROSPACEMATERIALSPECIFICATIONAMS-DTL-23053/15REV. AIssued 1999-07Revised 2012-10Supersedi

5、ng AMS-DTL-23053/15Insulation Sleeving, Electrical, Heat Shrinkable,Polyolefin, Heavy-Wall, Coated, Flexible, Outer Wall CrosslinkedFSC 5970RATIONALERevise to include comments received by the government and industry, update references, align specification with SAE guidelines, and review specificatio

6、n for known technical problems.The requirements for acquiring the sleeving described herein shall consist of this specification sheet and the issue of the following specification listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicit

7、ation: MIL-DTL-23053.REQUIREMENTS:Polymer type: The base polymer used in formulating the outer wall of this sleeving shall be a polyolefin.Continuous operating temperature range: -67 F (-55 C) to +230 F (+110 C).Color: The heat shrinkable sleeving shall be furnished in colors that conform to the req

8、uirements of Class II of MIL-STD-104. Black shall be the standard acquisition color. (See 1.2.1 and 3.4.2.1)Longitudinal change: +1 -10 percentClasses: The sleeving shall be furnished in the following classes, as specified (See 6.4a and 6.8):Class 1 - Heavy WallClass 2 - Medium WallCoatings: The inn

9、er wall of the sleeving shall be coated with an adhesive or sealant type material which shall effectively seal the enclosed area against moisture.Adhesive: Adhesive is for pressure retention and load bearing applications.Sealant: Sealant is for water hold out applications.SAE AMS-DTL-23053/15A Page

10、2 of 4Military part number: The Military part number shall consist of the basic number of this specification sheet and dash numbers shown as follows:M23053/15 - X XX - XExample: Class 1, black sleeving, 3.00 inch (76.2 mm) as supplied ID sleeving shall be identified as M23053/15-105-0.TABLE 1 - CONS

11、TRUCTION DETAILS, INCHES (MM) 1/Militarypart number 1/As suppliedID minimumAfter unrestricted shrinkageID maximum Wall Thickness 2/Class 1M23053/15-101-0 0.750 (19.05) 0.220 (5.59) 0.105 (2.667)M23053/15-102-0 1.100 (27.94) 0.375 (9.53) 0.120 (3.048)M23053/15-103-0 1.500 (38.10) 0.500 (12.70) 0.140

12、(3.556)M23053/15-104-0 2.000 (50.80) 0.750 (19.05) 0.155 (3.937)M23053/15-105-0 3.000 (76.20) 1.250 (31.75) 0.155 (3.937)M23053/15-106-0 4.000 (101.60) 1.750 (44.45) 0.155 (3.937)M23053/15-107-0 0.300 (7.62) 0.100 (2.54) 0.050 (1.270)M23053/15-108-0 0.400 (10.16) 0.150 (3.81) 0.060 (1.524)M23053/15-

13、109-0 1.300 (33.02) 0.375 (9.53) 0.120 (3.048)M23053/15-110-0 1.700 (43.18) 0.500 (12.70) 0.155 (3.937)M23053/15-111-0 2.700 (68.58) 0.900 (22.86) 0.155 (3.937)M23053/15-112-0 4.500 (114.30) 1.750 (44.45) 0.170 (4.318)Class 2M23053/15-201- 0.400 (10.16) 0.150 (3.81) 0.060 (1.524)M23053/15-202- 0.750

14、 (19.05) 0.220 (5.59) 0.060 (1.524)M23053/15-203- 1.100 (27.94) 0.375 (9.53) 0.105 (2.667)M23053/15-204- 1.300 (33.02) 0.375 (9.53) 0.105 (2.667)M23053/15-205- 1.500 (38.10) 0.500 (12.70) 0.120 (3.048)M23053/15-206- 1.700 (43.18) 0.500 (12.70) 0.140 (3.556)M23053/15-207- 2.700 (68.58) 0.900 (22.86)

15、0.155 (3.937)M23053/15-208- 2.000 (50.80) 0.750 (19.05) 0.140 (3.556)1/ Diameter limits for objectsto be enclosed shall be as recommended in technical data.2/ Wall thickness values are less when shrinkage is restricted.3/ As supplied ID is for uncoated product. An allowance of approximately 0.050 in

16、ch (1.3 mm) may be necessary depending on coating.Unrestricted shrinkage: Test method 4.6.5.2; 392 F 4 (200 C 2) for 10 minutes maximum.Color code designator (See 1.2.1)Size identifier (See Table 1)Class (Where no classes are specified in thespecification sheet, the numeric “0” is used)Specification

17、 sheetSAE AMS-DTL-23053/15A Page 3 of 4TABLE 2 - PHYSICAL PROPERTIESCharacteristic Requirement Test procedure and conditionsAs supplied:ID, minimum Table 1 4.6.3.1.1Low temperature flexibility No cracking 4.6.7.1 -67 F 4 (-55 C 2)Heat shock No cracking, flowing or dripping of outer wall4.6.8 437 F 6

18、 (225 C 3)Secant modulus, psi (MPa), maximum25 000 (172.4) 4.6.12.1 2 percent strain, ASTM D 882Color stability Pass 4.6.15 347 F 4 (175 C 2) 24 hoursAfter unrestricted shrinkage:ID, maximum Table 1 4.6.3.1.2Wall thickness Table 1 4.6.3.2Tensile strength, psi (MPa), minimum1200 (8.3) 4.6.13 ASTM D 6

19、38, 2 inches/minuteUltimate elongation, percent, minimum200 4.6.13 ASTM D 638, 2 inches/minuteDielectric strength, volts/mil (Kv/mm) minimum200 (7.9) 4.6.2 ASTM D 2671Volume resistivity, 0hm-cm, minimum10134.6.2 ASTM D 876Corrosion No corrosion 4.6.10.1 and 4.6.10.2, 250 F 4 (121 C 2) for 16 hoursFl

20、ammability 1/ 4.6.14 Procedure C ASTM D 2671Water absorption, percent, maximum0.5 4.6.2 ASTM D570 24 hrs at 23 CHeat resistance, properties after:4.6.9 347 F 4 (175 C 2), 168 hoursUltimate elongation, percent, minimum100Tensile strength, psi (MPa), minimum1000 (6.9)SAE AMS-DTL-23053/15A Page 4 of 4T

21、ABLE 2 - PHYSICAL PROPERTIES (CONT.)Characteristic Requirement Test procedure and conditionsFluid resistance, properties after:4.6.11Tensile strength, psi (MPa), minimum750 (5.2)Dielectric strength, volt/mil (Kv/mm), minimum200 (7.9)Fungus resistanceproperties after:Tensile Strength, psi (MPa), mini

22、mumUltimate elongation, percent, minimumDielectric strength, volts/mil (Kv/mm), minimumNo growthor1200 (8.2)200200 (7.9)4.6.2 ASTM G 214.6.171/ Record whether any flaming or glowing particles or flaming drops fall from the specimen. If more than 25 percent of the indicator flag is burned away or cha

23、rred (brown scorching and soot shall be ignored) after all of the five applications of flame or if flaming or glowing particles or flaming drops fall from the specimen at any time and ignite the cotton (flameless charring of the cotton shall be ignored), the specimen shall be judged to have conveyed

24、 flame and shall be considered as failing. In addition, any specimen which continues to flame or glow from one flame application longer than one minute shall not be acceptable.Storage life conditions: Supplier shall certify to storage at 65 to 95 F (18 to 35 C) for 2 years. Conformance to 3.5. See 3

25、.5.2 for storage life extension.Flammability: Only the outer jacket is flame retardant.Intended use: Heat shrinkable, flexible, heavy wall, coated sleeving is used for repair of heavy duty cables, splice covers.NOTESA change bar (l) located in the left margin is for the convenience of the user in lo

26、cating areas where technical revisions, not editorial changes, have been made to the previous issue of this document. An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (R) are not used in original publication

27、s, nor in documents that contain editorial changes only.Dimensions and properties in inch/pound units and the Fahrenheit temperatures are primary: dimensions and properties in SI units and the Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information.PREPARED BY AE-8D WIRE AND CABLE COMMITTEE

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1