SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf

上传人:medalangle361 文档编号:1022995 上传时间:2019-03-21 格式:PDF 页数:6 大小:46.40KB
下载 相关 举报
SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf_第1页
第1页 / 共6页
SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf_第2页
第2页 / 共6页
SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf_第3页
第3页 / 共6页
SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf_第4页
第4页 / 共6页
SAE ARP 488E-2010 Exits and Their Operation - Air Transport Cabin Emergency《出口及其操作 航空运输客舱紧急状况》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref

2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2010 SAE International All rights reserved. No part of this publication ma

3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US

4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/ARP488EAEROSPACERECOMMENDEDPRACTICEARP488 REV. E Issued 1957-08 Reaffirmed 1991-05 Revised 2010

5、-04Superseding ARP488D (R) Exits and Their Operation Air Transport Cabin Emergency RATIONALEThis revision updates the recommended design practices for emergency exits installed in the passenger cabin of transport category airplanes.1. SCOPE This SAE Aerospace Recommended Practice (ARP) provides desi

6、gn and performance recommendations for emergency exits in the passenger cabin. 1.1 PURPOSE The purpose of this ARP is to supplement the emergency exit certification requirements and guidance (e.g., FAA Part 25, EASA Part 25, FAA Advisory Circular 25.783-1A, etc.) by identifying design features that

7、will help to make the operation of airplane passenger exits safe, simple, quick, and more intuitive under normal and emergency conditions. This document is not intended to specify particular design methods or mechanisms to be used to accomplish the objectives established herein. 2. APPLICABLE DOCUME

8、NTS The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. However, nothing in this d

9、ocument supersedes applicable laws or regulations unless a specific exemption has been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA or Canada) or 724-776-4970 (outside USA), www.sae.org. ARP503 Emerg

10、ency Evacuation Illumination ARP577 Emergency Placarding - Internal and External2.2 FAA Publications Available from the Federal Aviation Administration, 800 Independence Avenue SW, Washington, D.C. 20591, Tel. 866-835-5322, www.faa.gov. Advisory Circular No. 25.783-1A Fuselage Doors and Hatches Copy

11、right SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP488E Page 2 of 62.3 Code of Federal Regulations Available from the United States Government Printing Office, 732 North Capitol Street, NW, Washingto

12、n, DC 20401, Tel: 202-512-0000, www.gpoaccess.gov. 14 CFR Part 25 Airworthiness Standards, Transport Category Airplanes 2.4 EASA Publications Available from European Aviation Safety Agency, Postfach 10 12 53, D-50452 Koeln, GermanyCS-25 EASA Certification Specifications for Large Aeroplanes 2.5 Tran

13、sport Canada Publications Available from Transport Canada, 330 Sparks Street, Ottawa, ON, K1A 0N5Advisory Circular No. 500-003 Emergency Exits Exposed to Freezing Rain 2.6 Definitions 2.6.1 5thPercentile Female: A female that is approximately 60 inches tall and weighs no more than 102 pounds.2.6.2 5

14、0thPercentile Male: A male that is approximately 70 inches tall and weighs 170 (+/- 5) pounds.2.6.3 95thPercentile Male: A male that is approximately 74 inches tall and weighs no less than 210 pounds. 2.6.4 Emergency Mode: The exit is in a condition such that its emergency power assist and evacuatio

15、n assist means (as applicable) are automatically activated upon opening the exit from the inside of the airplane (e.g., armed mode).2.6.5 Normal Mode: The exit is in a condition such that its emergency power assist and evacuation assist means (as applicable) are not activated upon opening the exit f

16、rom the inside of the airplane (e.g., disarmed mode).2.7 Mandating and Recommending Words 2.7.1 Shall: indicates a mandatory criterion 2.7.2 Should: indicates a criterion for which an alternative, including non-compliance, may be applied if it is documented and justified. 3. RECOMMENDATIONS 3.1 Gene

17、ral Recommendations 3.1.1 Each floor-level passenger cabin emergency exit should have similar operating procedures to the other floor-level emergency exits on an aircraft.3.1.2 An exit with a door/hatch that is automatically stowed out of the egress path when opened is preferable to a removable hatc

18、h that must be manually stowed. 3.1.3 For each exit design, the ability to operate the exit shall be demonstrated with the evacuation system in both the Normal and Emergency Modes. This should be accomplished by using a test sample of at least five participants who are representative of those expect

19、ed to operate the exit, including a 5thpercentile female and a 95thpercentile male. Each test participant should open the exit from the inside with it in the Normal Mode and separately with it in the Emergency Mode. 3.1.4 Increasing cabin differential pressure should act to increase the security and

20、 retention of the exit door/hatch. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP488E Page 3 of 63.1.5 Opening the exit at the maximum residual cabin differential pressure at which the exit

21、can be opened shall not create a hazard to the person opening the exit. 3.1.6 Means shall be provided to safeguard against inadvertent exit opening by passengers or crew during movement of the airplane on the ground or in flight. In addition, design precautions shall be taken to minimize the possibi

22、lity of a person intentionally opening the exit during flight, except where emergency procedures require in-flight opening of the exit (e.g., smoke evacuation). 3.1.7 The exit shall be fully openable in the Emergency Mode when the airplane is in adverse attitudes that correspond to the loss of one o

23、r more legs of landing gear. This should be demonstrated, using a 5thpercentile female, with the exit positioned in the worst-case attitude and taking into account the combined effects of the door/hatch weight, door/hatch motion and deployment of the evacuation assist means. 3.1.8 An exit equipped w

24、ith an emergency power assist system should be fully openable in the event of airplane power loss, while the airplane is positioned at its normal attitude (i.e., losing the power to an emergency power assisted exit shall not cause the exit to be unopenable). It should be demonstrated that a 50thperc

25、entile male can open the exit from inside the airplane without the benefit of the power assist system when the airplane is positioned at normal airplane attitude. 3.1.9 An exit designated as an entry or service door and equipped with an emergency power assist system and/or an evacuation assist means

26、 that can be automatically deployed when the exit is opened, shall be provided with a means inside the airplane, on or adjacent to the door/hatch, to allow opening of the exit without activation of these devices (i.e., the ability to arm/disarm the system). This exit shall also have a means to autom

27、atically prevent deployment of the assist means if the exit is opened from outside the airplane. The power assist system may activate if the exit is opened from the outside, provided it does not create a hazard to the person opening the exit. 3.1.9.1 An exit dedicated for emergency use only and equi

28、pped with an emergency power assist system and/or an evacuation assist means that is automatically deployed when the exit is opened, should be provided with a means inside the airplane, on or adjacent to the door/hatch, to allow opening of the exit without activation of these devices (i.e., the abil

29、ity to arm/disarm the system). For non-floor level exits, the means shall not be accessible to passengers. 3.1.9.2 Any potential hazards associated with opening an exit, which is dedicated for emergency use only, from the outside shall be identified in warning placards on the exterior of the exit (i

30、.e., automatic activation of a descent device and/or a door power assist system),3.1.9.3 The exit shall be openable in the event of ice buildup on the outside of the airplane. The ability to do so should be demonstrated by test. An acceptable test method is described in Transport Canada Advisory Cir

31、cular No. 500-003.3.1.9.4 The exit shall have a visual means that indicates when all required operations to close, latch, and lock the door have been completed. 3.1.9.5 The exit shall have a means to permit viewing of the conditions outside the airplane. If the outside viewing means cannot be positi

32、oned on the door, it may be located adjacent to the exit, provided there are no obstructions between it and the exit. The outside viewing means shall also permit viewing of the ground in the vicinity of where the evacuees would normally be expected to contact the ground when using the deployed evacu

33、ation assist means with the airplane in the normal attitude (all landing gear intact) and in the adverse attitudes corresponding to the loss of one or more legs of landing gear. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted wi

34、thout license from IHS-,-,-SAE ARP488E Page 4 of 63.2 Detail Recommendations 3.2.1 Opening Handle, Interior, Floor-Level Exits 3.2.1.1 The handle used for opening an exit in normal (non-emergency) conditions shall also be used for opening the exit in Emergency Mode. 3.2.1.2 The handle location and o

35、peration shall be obvious. The handle should be located on the door. If the handle cannot be located on the door, it should be positioned immediately adjacent to the door away from seated passengers.3.2.1.3 The entire operation of the handle shall be a smooth continuous motion, with no abrupt change

36、s in force or direction. Adequate hand clearance shall be provided throughout the handle travel, and the arc of handle rotation shall not exceed 180 degrees. 3.2.1.4 Secondary operations (e.g., removing covers, unlocking stops, straps, bars, or catches) shall not be necessary to open the exit in the

37、 emergency mode. 3.2.1.5 In the event that an exit is for some reason limited to partial opening, the handle should not further impede someones ability to use the exit. 3.2.1.6 The handle grip should be at least 10.2 cm (4 inches) wide, and the initial movement of the handle grip should be generally

38、 upwards. 3.2.1.7 The motion of the handle grip should provide the maximum mechanical advantage to assist in opening the exit. With the airplane in the normal attitude and subjected to the maximum normal allowable on-ground cabin pressure differential, the force required to operate the handle in the

39、 Emergency Mode should not exceed 222 newtons (50 pounds), and it shall be demonstrated that a 5thpercentile female can fully open the exit. 3.2.1.8 The range of motion of the handle grip, through its full travel, should be between 76 cm (30 inches) and 140 cm (55 inches) above the floor. 3.2.1.9 Th

40、e handle grip shall not be covered, hidden or obstructed by any cabin furnishings and shall contrast in color with the background and adjacent trim to enable locating the handle grip in emergency lighting conditions (see ARP503 for recommended emergency evacuation illumination levels). 3.2.1.10 The

41、interior handle shall automatically return to the closed position when the exit is closed from outside the airplane. When the exit is closed from the outside, movement of the interior handle shall not be hazarous to someone positioned inside of the airplane near the exit. 3.2.2 Opening Handle, Inter

42、ior, Non-Floor-Level Exits 3.2.2.1 The opening handle location and operation shall be obvious. The handle should be located on and positioned near the top of the door/hatch. The handle should be clearly visible and accessible, even if covered by a cover intended to preclude inadvertent opening by a

43、passenger.3.2.2.2 The handle grip should be at least 10.2 cm (4 inches) wide. 3.2.2.3 The motion of the handle grip shall provide the maximum mechanical advantage to assist in opening the exit. For removable hatches, the motion of the handle grip should facilitate the removal and handling of the hat

44、ch. With the airplane in the normal attitude and subjected to the maximum allowable on-ground cabin pressure differential, the force required to operate the handle in Emergency Mode should not exceed 222 newtons (50 pounds), and it shall be demonstrated that a 5thpercentile female can fully open the

45、 exit. 3.2.2.4 If the exit can be closed from the outside, the interior handle shall automatically return to the closed position when the exit is closed from outside the airplane. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted

46、without license from IHS-,-,-SAE ARP488E Page 5 of 63.2.3 Opening Handle, Exterior, Floor-Level and Non-Floor-Level Exits 3.2.3.1 For floor-level exits that are normally opened from an elevated platform (jetway, aerostand, etc.), the range of motion of the handle grip, through its full travel, shoul

47、d be between 76 cm (30 inches) and 140 cm (55 inches) above the exit sill. 3.2.3.2 The handle grip should be at least 12.7 cm (5 inches) wide. 3.2.3.3 Clearance shall be provided to allow gripping the exterior handle with gloved hands. 3.2.3.4 With the airplane in the normal attitude and subjected t

48、o the maximum allowable on-ground cabin pressure differential, the force required to operate the handle should not exceed 222 newtons (50 pounds) on each handle grip, if two handle grips are provided, or 334 newtons (75 pounds) if a single handle grip is provided. It shall be demonstrated that a 50t

49、hpercentile male can fully open the exit under these conditions. 3.2.3.5 The exterior handle shall automatically return to the closed and stowed position when the exit is closed from inside the airplane. When the exit is closed from the inside, movement of the exterior handle shall not be hazarous to someone positioned outside

展开阅读全文
相关资源
猜你喜欢
  • ETSI TR 102 021-8-2003 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 Part 8 Air - Ground - Air services (V1 1 1)《陆地集群无线电(TETRA) TETRA的用户需求规范第2次发布.pdf ETSI TR 102 021-8-2003 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 Part 8 Air - Ground - Air services (V1 1 1)《陆地集群无线电(TETRA) TETRA的用户需求规范第2次发布.pdf
  • ETSI TR 102 021-8-2003 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 Part 8 Air - Ground - Air services (V1 1 1)《陆地集群无线电(TETRA) TETRA的用户需求规范第2次发布_1.pdf ETSI TR 102 021-8-2003 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 Part 8 Air - Ground - Air services (V1 1 1)《陆地集群无线电(TETRA) TETRA的用户需求规范第2次发布_1.pdf
  • ETSI TR 102 021-9-2010 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 1 Part 9 Peripheral Equipment Interface (V1 2 1)《陆地集群无线电(TETRA) TETRA的用户需求规范.pdf ETSI TR 102 021-9-2010 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 1 Part 9 Peripheral Equipment Interface (V1 2 1)《陆地集群无线电(TETRA) TETRA的用户需求规范.pdf
  • ETSI TR 102 021-9-2010 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 1 Part 9 Peripheral Equipment Interface (V1 2 1)《陆地集群无线电(TETRA) TETRA的用户需求规范_1.pdf ETSI TR 102 021-9-2010 Terrestrial Trunked Radio (TETRA) User Requirement Specification TETRA Release 2 1 Part 9 Peripheral Equipment Interface (V1 2 1)《陆地集群无线电(TETRA) TETRA的用户需求规范_1.pdf
  • ETSI TR 102 022-1-2012 User Requirement Specification Mission Critical Broadband Communication Requirements (V1 1 1 Includes Diskette)《用户需求规范 关键任务宽带通信需求 版本1 1 1 包括磁盘》.pdf ETSI TR 102 022-1-2012 User Requirement Specification Mission Critical Broadband Communication Requirements (V1 1 1 Includes Diskette)《用户需求规范 关键任务宽带通信需求 版本1 1 1 包括磁盘》.pdf
  • ETSI TR 102 022-2-2015 User Requirements Specification Mission Critical Broadband Communications Part 2 Critical Communications Application (V1 1 1)《用户需求 规范任务关键宽带通信 第2部分 关键通信应用 (V1.pdf ETSI TR 102 022-2-2015 User Requirements Specification Mission Critical Broadband Communications Part 2 Critical Communications Application (V1 1 1)《用户需求 规范任务关键宽带通信 第2部分 关键通信应用 (V1.pdf
  • ETSI TR 102 022-2-2018 User Requirements Specification Mission Critical Broadband Communications Part 2 Critical Communications Application (V1 2 1).pdf ETSI TR 102 022-2-2018 User Requirements Specification Mission Critical Broadband Communications Part 2 Critical Communications Application (V1 2 1).pdf
  • ETSI TR 102 024-1-2003 Telecommunications and Internet Protocol Harmonization Over Networks (TIPHON) Release 4 End-to-end Quality of Service in TIPHON Systems Part 1 General aspect.pdf ETSI TR 102 024-1-2003 Telecommunications and Internet Protocol Harmonization Over Networks (TIPHON) Release 4 End-to-end Quality of Service in TIPHON Systems Part 1 General aspect.pdf
  • ETSI TR 102 024-1-2003 Telecommunications and Internet Protocol Harmonization Over Networks (TIPHON) Release 4 End-to-end Quality of Service in TIPHON Systems Part 1 General aspect_1.pdf ETSI TR 102 024-1-2003 Telecommunications and Internet Protocol Harmonization Over Networks (TIPHON) Release 4 End-to-end Quality of Service in TIPHON Systems Part 1 General aspect_1.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1