资源描述

1、AEROSPACE STANDARDTERMINAL, LUG, UNINSULATED, RECTANGULARTONGUE, CRIMP STYLE, COPPER, TYPE I, CLASS 1FOR 175 C TOTAL CONDUCTOR TEMPERATUREAS21004Copyright 2016 SAE InternationalAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any for

2、m or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA)Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/

3、www.sae.orgISSUED2002-02REVISED2016-10THIRD ANGLE PROJECTIONCUSTODIAN: AE-8/AE-8C2REV. CFEDERAL SUPPLY CLASS5940AS21004SHEET 1 OF 3REV.CPROCUREMENT SPECIFICATION: AS7928SAE Technical Standards BoardRules providethat:“This reportis publishedby SAE to advance thestateoftechnical andengineering science

4、s. The useofthis reportis entirely voluntary, and its applicability and suitability forany particularuse, includingany patent infringement arising therefrom,is thesole responsibility of theuser.”SAE reviews eachtechnical reportatleastevery fiveyears at whichtime it may berevised, reaffirmed, stabili

5、zed, or cancelled. SAEinvites your written comments and suggestions.SAE values your input. To provide feedback on thisTechnical Report, please visit http:/standards.sae.org/AS21004CRATIONALEREVISION REQUIRED TO INSERT DIVIDING LINES IN TABLE 1 AS ORIGINALLY SHOWN IN AS21004A AND CHANGE DIMENSION H F

6、OR THE MS21004-11.NOTICETHE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THISDOCUMENT AND THE LATEST ISSUE OF AS7928.FIGURE 1 - TERMINAL CONFIGURATIONAEROSPACE STANDARDAS21004SHEET 2 OF 3REV.CTERMINAL, LUG, UNINSULATED, RECTANGULARTONGUE, CRIMP STYLE, COPPER, TYP

7、E I, CLASS 1FOR 175 C TOTAL CONDUCTOR TEMPERATURETABLE 1 - TERMINAL CONFIGURATION DIMENSIONSDASHNO.WIRESIZESTUDSIZEAMAXBMINC+.010 D E FG H L W MIL-T-16366(SHIPS)REFERENCEMAX MIN MIN MAX .00522 1/22-182 (.086) .759 .240 .110.037.023.165.110.070.052.098 .090 .203 .125 .1821 4 (.112) .826.250.143 .122

8、.114 .237 .125 .237 L-86, 1-22 5 (.125) .858 .143 .137 .129 .277 .125 .277 L-83, 1-23 8 (.164) 1.040 .227 .178 .168 .465 .250 .302 L-82, 1-24 6 (.138) 1.040 .227 .152 .142 .465 .250 .302 L-81, 1-25 4 (.112) .980 .195 .122 .114 .404 .156 .237 L-85, 1-26 6 (.138) .980 .195 .152 .142 .404 .166 .237 L-8

9、4, 1-27 8 (.164) 1.290 .310 .178 .168 .621 .281 .390 L-80, 1-2816-144 (.112) .889.250.143.037.023.192.139.090.081.122 .114 .237 .125 .237 L-86, 2-1/2-49 5 (.125) .921 .143 .137 .129 .277 .125 .277 L-83, 2-1/2-410 8 (.164) 1.075 .227 .178 .168 .465 .250 .302 L-82, 2-1/2-411 6 (.138) 1.075 .227 .152 .

10、142 .465 .250 .302 L-81, 2-1/2-412 4 (.112) 1.043 .195 .122 .114 .404 .166 .237 L-85, 2-1/2-413 6 (.138) 1.043 .195 .152 .142 .404 .156 .237 L-84, 2-1/2-414 8 (.164) 1.294 .310 .178 .168 .621 .281 .390 L-80, 2-1/2-41512-104 (.112) 1.014.250.143.043.033.255.199.135.128.122 .114 .237 .125 .237 L-86, 6

11、-916 5 (.125) 1.146 .143 .137 .129 .277 .125 .277 L-83, 6-917 8 (.164) 1.200 .227 .178 .168 .465 .250 .302 L-82, 6-918 6 (.138) 1.200 .227 .152 .142 .465 .250 .302 L-81, 6-919 4 (.112) 1.168 .195 .122 .114 .404 .156 .237 L-85, 6-920 6 (.136) 1.168 .195 .152 .142 .404 .156 .237 L-84, 6-921 8 (.164) 1

12、.419 .310 .178 .168 .621 .281 .390 L-80, 6-91/ TERMINAL SIZE 22 IS NOT RECOMMENDED FOR USAGE. THERE IS NO KNOWN SOURCE OF SUPPLY. CONTACT THE AS21004 QUALIFIED SOURCE FOR FURTHER SUPPORT.REQUIREMENTS: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS7928.1. TERMINAL CONFIGUR

13、ATION:TERMINAL CONFIGURATION IS AS SHOWN IN FIGURE 1 AND TABLE 1. DESIGN IS OPTIONAL WITHIN THE DIMENSIONS SHOWN. DIMENSIONS ARE INCHES. STUD SIZE DIMENSIONS ARE SHOWN IN PARENTHESES.2. MATERIAL:TERMINAL SHALL BE TIN PLATED OVER COPPER BASE METAL.3. PART IDENTIFICATION NUMBER (PIN):MS21004 -21I II I

14、_ DASH NUMBER (SEE TABLE 1)I_ AS7928 DETAIL SPECIFICATION NUMBER4. CRIMP TOOLS:TERMINAL SHALL BE CRIMP WITH THE TOOLS SPECIFIED IN TABLE 2. CLASS II TOOLS MAY BE USED IN ACCORDANCE WITH AS7928.TABLE 2 - CRIMP TOOLS PART NUMBERSMS21004 WIRE SIZEM22520/38-1 CRIMP CAVITYM22520/24-1 CRIMP CAVITY 1/22 TH

15、ROUGH 14 AB AB12 THROUGH 10 C C1/ AS22520/38 SUPERSEDES MIL-DTL-22520/24 WHICH IS NOT RECOMMENDED FOR FUTURE USE.AEROSPACE STANDARDAS21004SHEET 3 OF 3REV.CTERMINAL, LUG, UNINSULATED, RECTANGULARTONGUE, CRIMP STYLE, COPPER, TYPE I, CLASS 1FOR 175 C TOTAL CONDUCTOR TEMPERATURE5. QUALIFICATION CABLES:A

16、S7928 QUALIFICATION SHALL BE PERFORMED WITH MIL-DTL-915 SINGLE CONDUCTOR CABLE.6. APPLICATIONS:FOR SIMILAR MIL-T-16366 TERMINALS FOR SHIP BOARD APPLICATION SEE TABLE 1.FOR TERMINAL BOARD APPLICATIONS THE COMBINATION OF DIMENSIONS H, C, AND L PERMITS WIRED TERMINALS TO BE STACKED ON ONE STUD AS LISTE

17、D IN TABLE 3.TABLE 3 - A-A-55125STYLETERMINAL BOARDA-A-59125QUANTITY OFWIRED TERMINALSL80 -/10 4L81 -/12 4L82 -/19 4L83 -/14 2L84 -/16 4L85 -/25 3L86 -/24 2PURE TIN COATED TERMINALS CLOSELY SPACED ON ELECTRONIC EQUIPMENT NEED TO BE CONSIDERED, BECAUSE OF THE POTENTIAL FOR TIN WHISKER GROWTH.SPECIFIC

18、ATION NOTES1. REVISION INDICATOR: A CHANGE BAR (I) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THISDOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.