1、AEROSPACE STANDARDWIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED,EXTRA HIGH STRENGTH COPPER ALLOY,200 C, 600 VOLT, ROHSAS22759TM/95Copyright 2016 SAE InternationalAll rights reserved. No part of this publication may be reproduced, stored in a retrieval sys
2、tem or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA)Fax: 724-776-0790 Email: CustomerServices
3、ae.org SAE WEB ADDRESS: http:/www.sae.orgISSUED2016-07THIRD ANGLE PROJECTIONCUSTODIAN: AE-8/AE-8DFEDERAL SUPPLY CLASS6145AS22759TM/95SHEET 1 OF 4PROCUREMENT SPECIFICATION: AS22759SAE Technical Standards BoardRules providethat:“This reportis publishedby SAE to advance thestateoftechnical andengineeri
4、ng sciences. The useofthis reportis entirely voluntary, and its applicability and suitability forany particularuse, includingany patent infringement arising therefrom, is thesole responsibility of theuser.”SAE reviews eachtechnical reportatleastevery five years at whichtime it may bereaffirmed, revi
5、sed, stabilized or cancelled. SAE invites your written commentsand suggestions.SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS22759/95RATIONALESPECIFICATION DEVELOPED FOR APPLICATIONS REQUIRING HIGHER CONDUCTOR TENSILE STRENGT
6、H WHILE MAINTAINING ELECTRICAL CONDUCTIVITY. THIS SPECIFICATION USES THE EXTRA HIGH STRENGTH CLASSIFICATION OF SILVER PLATED COPPER ALLOY CONDUCTOR FROM AS29606.NOTICETHE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759.T
7、HIS SPECIFICATION IS NOT INTENDED FOR USE IN NAVAL AIRCRAFT OR NAVAL AIR SYSTEMS APPLICATIONS.FP / POLYIMIDE / FP TAPE FP TAPEFP FLUOROCARBON POLYMER MODIFIED POLYTETRAFLUOROETHYLENE (PTFE)CONDUCTOR STRANDED SILVER COATED EXTRA HIGH STRENGTH COPPER ALLOYFIGURE 1 - AS22759/95 CONFIGURATIONTABLE 1 - C
8、ONSTRUCTION DETAILS FOR FINISHED WIREPART NO. 1/WIRESIZECONDUCTOR 3/ FINISHED WIRESTRANDING(NUMBER OFSTRANDSX SIZEGAUGE OFSTRANDS)DIAMETER(IN) RESISTANCEAT 20 C(68 F)(OHMS/1000FEET MAX)DIAMETER(IN)WEIGHT(LB/1000 FEET) 2/MIN MAX MIN MAX MIN TARGET MAXM22759/95-30-*M22759/95-28-*M22759/95-26-*M22759/9
9、5-24-*M22759/95-22-*M22759/95-20-*3028262422207 X 387 X 3619 X 3819 X 3619 X 3419 X 320.01170.01470.01840.02310.02930.03730.01240.01540.02040.02440.03140.0395117.474.444.828.417.510.70.0260.0290.0330.0380.0430.0510.0290.0330.0370.0420.0470.0550.750.971.341.872.704.250.831.051.472.042.904.450.911.121
10、.602.203.104.651/ PART NUMBER: THE ASTERISKS IN THE PART NUMBER COLUMN OF TABLE 1 SHALL BE REPLACED BY COLOR CODE DESIGNATORS IN ACCORDANCE WITH MIL-STD-681. EXAMPLES: M22759/95-20-93 IS A 20 AWG WHITE WITH ORANGE STRIPE.2/ THE ACCEPTABLE VALUE FOR THE CPK FOR THE FINISHED WIRE WEIGHT LISTED SHALL B
11、E 1.3, USING A NORMAL (GAUSSIAN) DISTRIBUTION TO OBTAIN THOSE CPK VALUES.3/ CONDUCTOR SHALL CONFORM TO AS29606 TYPE SCS SMALL DIAMETER SILVER COATED EXTRA HIGH STRENGTH COPPER ALLOY CONDUCTOR.AEROSPACE STANDARDAS22759TM/95SHEET 2 OF 4WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, NORM
12、AL WEIGHT, SILVER COATED,EXTRA HIGH STRENGTH COPPER ALLOY,200 C, 600 VOLT, ROHSREQUIREMENT: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759.1. WIRE CONSTRUCTION:WIRE CONSTRUCTION SHALL BE IN ACCORDANCE WITH FIGURE 1 AND TABLES 1, 2, 3, AND 4.TABLE 2 - WIRE INSULATION
13、MATERIALS TAPE CODE THICKNESS (NOM) MATERIAL1 0.0020 0.0005 (FP)/0.0010 (POLYIMIDE)/0.0005 (FP)2 0.0020 FP (UNSINTERED)TABLE 3 - TAPE OVERLAP REQUIREMENTS 1/WIRESIZEWRAP 1 WRAP 2 NOMINALWALLTHICKNESS(MILS)TAPECODEPERCENTOVERLAP TAPECODEPERCENTOVERLAPMIN MAX MIN MAX30 1 50.5 54.0 2 50.5 54.0 7.428 1
14、50.5 54.0 2 50.5 54.0 7.426 1 50.5 54.0 2 50.5 54.0 7.424 1 50.5 54.0 2 50.5 54.0 7.422 1 50.5 54.0 2 50.5 54.0 7.420 1 50.5 54.0 2 50.5 54.0 7.41/ WRAP 1 IS INNERMOST TAPE WHICH IS IN CONTACT WITH THE CONDUCTOR. 2. WIRE PERFORMANCE RATING:TEMPERATURE RATING: 200 C (392 F) MAXIMUM CONDUCTOR CONTINUO
15、US TEMPERATURE.VOLTAGE RATING: 600 VOLTS (RMS) AT SEA LEVEL. THIS INSULATION SYSTEM HAS BEEN USED IN AEROSPACE APPLICATIONS USING 115 VOLTS (PHASE TO NEUTRAL), 400 HERTZ AC AND 28 VOLTS DC. VERIFICATION OF THE SUITABILITY OF THIS PRODUCT FOR USE IN OTHER ELECTRICAL SYSTEM CONFIGURATIONS IS THE RESPO
16、NSIBILITY OF THE USER.3. MATERIALS AND PHYSICAL PROPERTIES:SEE AS22759 FOR MATERIAL REQUIREMENT. MATERIALS USED IN THE MANUFACTURE OF THESE PRODUCTS SHALL COMPLY WITH THE RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 2002/95/EC. 4. FINISH WIRE INSULATION PROPERTIES:FINISH WIRE INSULATION PROPERTIES
17、SHALL BE IN ACCORDANCE WITH TABLE 4.TABLE 4 - FINISHED WIRE INSULATION PROPERTIES REQUIREMENTSINSULATION PROPERTIESIMPULSE TEST VOLTAGE 8.0 KILOVOLTS (PEAK)HIGH FREQUENCY TEST VOLTAGE 5.7 KILOVOLTS (RMS) INSULATION STATE OF SINTER 3.0 JOULES PER GRAM MAXIMUMTAPE OVERLAP TABLE 3LAMINATION SEALING 260
18、 C 2 C (500 F 3.6 F), 6 HOURSINSULATION BLOCKING 200 C 2 C (392 F 3.6 F)SHRINKAGE 230 C 2 C (446 F 3.6 F)MAXIMUM CHANGE .091 INCHESELECTRICAL RESISTANCE (IR) 5000 MEGOHMS (MIN)-1000 FEETWET DIELECTRIC VOLTAGE 2500 VOLTS (RMS), 60 HERTZINSULATION STRIP FORCE .25 - 6.0 POUNDS: WIRE SIZES 26 - 20NOT RE
19、QUIRED FOR WIRE SIZES 30 - 28UV LASER MARKING 55% MINIMUM AVERAGECONTINUOUS LENGTH SCHEDULE BAEROSPACE STANDARDAS22759TM/95SHEET 3 OF 4WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED,EXTRA HIGH STRENGTH COPPER ALLOY,200 C, 600 VOLT, ROHS5. FINISH WIRE IDENT
20、IFICATION:WIRE IDENTIFICATION EXCEPTIONS: NONEWIRE IDENTIFICATION DURABILITY: 125 CYCLES (250 STROKES) WITH 250 GRAMS WEIGHT STRIPE AND BAND DURABILITY: 125 CYCLES (250 STROKES) WITH 250 GRAMS WEIGHT6. FINISH WIRE PERFORMANCE:FINISH WIRE FIXTURES APPLICABLE TO EACH WIRE SIZE SHALL BE IN ACCORDANCE W
21、ITH TABLE 5.TABLE 5 - TEST MANDREL AND TEST LOAD REQUIREMENTSWIRESIZE(AWG)TEST MANDREL DIAMETER 1/(INCHES)TEST LOAD 1/(LB)COLD BENDLIFE CYCLE/BEND TEST WRAP COLD BENDLIFE CYCLE/BEND TEST3028262422201.001.001.001.001.001.000.3750.3750.3750.5000.5000.5000.1250.1250.1250.1250.1250.1252.002.003.003.004.
22、004.00 0.250.250.500.751.001.501/ TOLERANCE SHALL BE 3% OF THE GIVEN VALUES.FINISH WIRE PERFORMANCE CHARACTERISTICS SHALL BE IN ACCORDANCE WITH TABLE 6.TABLE 6 - FINISH WIRE PERFORMANCE CHARACTERISTICSPERFORMANCE CHARACTERISTIC REQUIREMENTMANDREL BEND RESISTANCE (TAPES/BRAIDS) REQUIREDTHERMAL SHOCK
23、MECHANICAL RESISTANCE TEMPERATURE EXPOSURE 200 C 2 C (392 F 3.6 F)MAXIMUM CHANGE .091 INCHESTHERMAL MECHANICAL RESISTANCE (LIFE CYCLE)EXPOSURE 500 HOURS, 230 C 2 C (446 F 3.6 F)HUMIDITY RESISTANCE (IR) 5000 MEGOHMS (MIN)-1000 FEETFLUID RESISTANCE DIAMETER INCREASE 5% (MAX)SMOKE RESISTANCE 200 C 5 C
24、(392 F 9 F)FLAME RESISTANCE SELF-EXTINGUISH TIME: 3 SECONDSBURN LENGTH 3 INCHESWET ARC RESISTANCE MINIMUM 67 WIRES PASS WET DIELECTRIC TEST3 OR LESS WIRES FAIL IN ONE BUNDLEDAMAGE LENGTH: 3.0 INCHES OF LESSDRY ARC RESISTANCE MINIMUM 67 WIRES PASS WET DIELECTRIC TEST3 OR LESS WIRES FAIL IN ONE BUNDLE
25、DAMAGE LENGTH: 3.0 INCHES OF LESSDYNAMIC CUT-THROUGH WIRE SIZE 2610 POUNDS AT 23 C, 8 POUNDS AT 150 C, 6 POUNDS AT 200 CWIRE SIZE 2015 POUNDS AT 23 C, 12 POUNDS AT 150 C, 10 POUNDS AT 200 CFORCED HYDROLYSIS INSULATION RESISTANCEWIRE SIZE 2070 C 2 C (158 F 3.6 F), 5000 HOURSLONGEVITY RESISTANCE (THER
26、MAL INDEX) 200 C 2 C (392 F 3.6 F), 10000 HOURSAEROSPACE STANDARDAS22759TM/95SHEET 4 OF 4WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, NORMAL WEIGHT, SILVER COATED,EXTRA HIGH STRENGTH COPPER ALLOY,200 C, 600 VOLT, ROHS7. REQUIREMENT EXCEPTION TO THE AS22759:NONEAPPLICATION NOTES1. PR
27、ODUCTS MANUFACTURED TO THIS SPECIFICATION ARE ROHS COMPLIANT. SPECIFICATION NOTES1. REVISION INDICATOR:A CHANGE BAR (l) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS NOR IN DOCUMENTS THATCONTAIN EDITORIAL CHANGES ONLY.