SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf

上传人:livefirmly316 文档编号:1024250 上传时间:2019-03-21 格式:PDF 页数:7 大小:485.75KB
下载 相关 举报
SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf_第1页
第1页 / 共7页
SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf_第2页
第2页 / 共7页
SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf_第3页
第3页 / 共7页
SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf_第4页
第4页 / 共7页
SAE AS 39029 104-2000 Contacts Electrical Connector Concentric Twinax Pin Shielded Size 8 (for MIL-C-28840)《接触点 电气连接件 屏蔽双导线馈电线 插头 带护鞘的的电气连接件 尺寸8》.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、Copyright 2000 Society of Automotive Engineers, Inc. Printed in the U.S.A.All rights reserved. .TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX: (724) 776-0790 SAE WEB ADDRESS: http:/www.sae.org400 Commonwealth Drive, Warrendale, PA 15096-0001SAE Technical StandardsBoard Rulesprovidethat:“Thisreport i

2、s published by SAEtoadvance thestateoftechnical and engineeringsciences. The useofthis reportisentirelyvoluntary, and its applicabilityand suitability for any particularuse, includingany patent infringement arising therefrom, isthe soleresponsibility of the user.”SAE reviews each technical report at

3、 least every five years at whichtime it maybereaffirmed, revised, or cancelled. SAE invites your writtencomments and suggestions.SHEET 1 OF 7AS39029/104THIRD ANGLE PROJECTIONAEROSPACE STANDARDAS39029/104ISSUED2000-07CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28

4、840)PREPARED BY SAE SUBCOMMITTEE AE-8C1FEDERAL SUPPLY CLASS 5935NOTICETHIS DOCUMENT HAS BEEN TAKEN DIRECTLY FROM U.S. MILITARY SPECIFICATION MIL-C-39029/104 AND CONTAINS ONLY MINOR EDITORIAL AND FORMAT CHANGES REQUIRED TO BRING IT INTO CONFORMANCE WITH THE PUBLISHING REQUIREMENTS OF SAE TECHNICAL ST

5、ANDARDS. THE INITIAL RELEASE OF THIS DOCUMENT IS INTENDED TO REPLACE MIL-C-39029/104. ANY PART NUMBERS ESTABLISHED BY THE ORIGINAL SPECIFICATION REMAIN UNCHANGED.THE ORIGINAL MILITARY SPECIFICATION WAS ADOPTED AS AN SAE STANDARD UNDER THE PROVISIONS OF THE SAE TECHNICAL STANDARDS BOARD (TSB) RULES A

6、ND REGULATIONS (TSB 001) PERTAINING TO ACCELERATED ADOPTION OF GOVERNMENT SPECIFICATIONS AND STANDARDS. TSB RULES PROVIDE FOR (A) THE PUBLICATION OF PORTIONS OF UNREVISED GOVERNMENT SPECIFICATIONS AND STANDARDS WITHOUT CONSENSUS VOTING AT THE SAE COMMITTEE LEVEL, AND (B) THE USE OF THE EXISTING GOVE

7、RNMENT SPECIFICATION OR STANDARD FORMAT.UNDER DEPARTMENT OF DEFENSE POLICIES AND PROCEDURES, ANY QUALIFICATION REQUIREMENTS AND ASSOCIATED QUALIFIED PRODUCTS LISTS ARE MANDATORY FOR DOD CONTRACTS. ANY REQUIREMENT RELATING TO QUALIFIED PRODUCTS LISTS (QPLS) HAS NOT BEEN ADOPTED BY SAE AND IS NOT PART

8、 OF THIS SAE TECHNICAL DOCUMENT.400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 2 OF 7AS39029/104THE REQUIREMENTS FOR ACQUIRING THE CONTACTS DESCRIBED HEREIN SHALL CONSIST OF

9、THIS SPECIFICATION AND THE LATEST ISSUE OF MIL-C-39029.FIGURE 1. CONCENTRIC TWINAX CONTACT.400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 3 OF 7AS39029/104FIGURE 2. INTERMEDI

10、ATE SOCKET CONTACT.FIGURE 3. CENTER PIN CONTACT.400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 4 OF 7AS39029/104REQUIREMENTS:Qualification:Contacts shall comply with the reli

11、ability assurance provisions of MIL-STD-790 as specified in MIL-C-28840.Design and construction:Dimensions and configurations: See figures 1 through 3 and table I.TABLE I. DESIGN CHARACTERISTICS.Assembly procedure: Manufacturers recommended assembly instructions shall be shipped with unit package.El

12、ectrical:Low signal level contact resistance (center and intermediate contacts only): See table II.Contact resistance: See table III.Frequency: 0 to 20 MHz (operating frequency range).Voltage rating: 500 volts rms maximum; working voltage at sea level, 125 volts rms maximum at 70,000 feet.TABLE II.

13、LOW SIGNAL LEVEL CONTACT, RESISTANCE (CENTER AND INTERMEDIATE CONTACTS ONLY).TABLE III. CONTACT RESISTANCE.400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 5 OF 7AS39029/104Die

14、lectric withstanding voltage: Shall be as specified in table IV.TABLE IV. DIELECTRIC WITHSTANDING VOLTAGE.Mating contact: Shall be in accordance with MIL-C-39029/105.Mechanical:Contact engagement and separation force (socket contacts only): The engagement depth shall be a minimumof 0.7 of the minimu

15、m socket bored depth. The test pins shall be in accordance with MS3197, except thediameters shall be as specified in table V. Provision for clearance hole on outer contact. Test pins shall beprovided.TABLE V. CONTACT ENGAGEMENT AND SEPARATION FORCE.Crimp tensile strength (center, intermediate, and o

16、uter contact crimp joint): See table VI.TABLE VI. CRIMP TENSILE STRENGTH (AT AMBIENT).Vibration: Method 2005 of MIL-STD-1344, test condition V. The following details shall apply:a. Use the vibration envelope shown on figure 4.b. Vibration: To be conducted at standard test conditions.c. Duration: Eig

17、ht hours in the longitudinal direction and 8 hours in a perpendicular direction (16 hours).400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 6 OF 7AS39029/104FIGURE 4. VIBRATION

18、 ENVELOPE.High impact shock: All contacts shall be wired in a series circuit with 100 milliampers maximum current flow through the series circuit during shock. Contacts shall be monitored for any discontinuities. A detector capable of detecting all discontinuities in excess of 1 microsecond shall be

19、 used. Wired and mated contacts shall be subjected to the test specified in MIL-S-901, grade A with the following modifications and additions. Mounting fixture shall be in accordance with MIL-S-901. The cable or wire bundle shall be supported on a stationary frame to provide a free flexing cable len

20、gth between the frame and fixture of not less than 36 inches (914.4 mm).a. Coupling: Coupled by normal mounting means.b. Test condition A: The wire bundle shall be provided with straight, open frame, strain relief accessory hardware.Tools: Shall be as specified in tables VII and VIII.TABLE VII. TOOL

21、S (INSTALLING AND REMOVAL).400 Commonwealth Drive, Warrendale, PA 15096-0001CONTACTS, ELECTRICAL CONNECTOR,CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8(FOR MIL-C-28840)AEROSPACE STANDARD AS39029/104SHEET 7 OF 7AS39029/104TABLE VIII. TOOLS (CRIMPING).Environmental:Temperature rating: -55C to +200C.Humidity: In accordance with MIL-STD-1344, method 1002, type II.Part number: See table IX.TABLE IX. PART NUMBER.QPL evaluating activity: Naval Weapons Support Center, Crane, IN 47522.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1