1、 AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5 Copyright 2007 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electr
2、onic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-04
3、REVISED 2007-09 THIRD ANGLE PROJECTION CUSTODIAN: SAE AE-8/AE-8D REV. A FEDERAL SUPPLY CLASS6010 AS5382/5 SHEET 1 OF 4 REV. A PROCUREMENT SPECIFICATION: NONESAE TechnicalStandards Board Rules provide that: “This report is published by SAE toadvance thestate of technical andengineering sciences.The u
4、se of thisreport is entirely voluntary, andits applicabilityandsuitability forany particularuse,including any patent infringement arising therefrom, is thesole responsibility oftheuser.” SAE reviews each technical report at least every five yearsat which time it may be reaffirmed, revised, orcancell
5、ed.SAE invites yourwritten commentsandsuggestions.RATIONALE REVISED TO MAKE CABLE MORE PRODUCIBLE. FIGURE 1 - CABLE CONFIGURATION 1. Construction Description 1.1 Optical Fiber Dimensions and Materials Core Diameter: 50 m 3.0 m (0.00195 in 0.00012 in) Core Material: Graded Index Silica Glass Cladding
6、 Diameter: 125 m 2 m (0.0049 in 0.00008 in) Cladding Material: Silica Glass Core to Cladding Ellipticity: 3% maximum Core to Cladding Offset: 3 m maximum Hermetic Coated: Yes Coating Diameter: 450 m 25 m (0.0177 in 0.001 in) Coating Material: Silicone Coating Concentricity: 65% minimum 125 MICRON OD
7、 HERMETIC COATED GLASS FIBER SILICONE BUFFER ETFE UPJACKET BRAIDED PARA-ARAMID FIBER STRENGTH MEMBER 1.8 MM ETFE OUTER JACKET AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5 SHEET 2 OF 4 REV. A 1.2 Cable Dimensions and Materials U
8、pjacket Diameter: 900 m 50 m (0.0354 in 0.002 in) Upjacket Material: Ethylene-Tetrafluoroethylene Copolymer (ETFE) Strength Member: Braided Para-Aramid Fiber Yarn Size: 380 Denier Number of Ends: 16 Braid Picks/Inch: 14.5 Outer Jacket Diameter: 1800 m 100 m (0.0709 in max 0.039 in max) Outer Jacket
9、Material: Ethylene-Tetrafluoroethylene Copolymer (ETFE) Outer Jacket Concentricity: 6% of Jacket Outer Diameter 1.3 Cable Performance Operational Mode: Multi-mode Temperature Rating: -55 to +165 C Storage Temperature: -55 to +85 C Outer Jacket Color: Orange Finished Cable Weight: 4.0 kg/km maximum 2
10、. Optical Fiber Requirements Maximum Attenuation: 6 dB/km 850 nm, 4 dB/km 1300 nm Numerical Aperture: 0.20 0.02 Fiber Tensile Proof Test: 200,000 psi minimum Bandwidth 400 MHz-km 850 nm & 1300 nm 3. Environmental Fluid Immersion: See Table 1 for test fluid listing. Freezing Water Immersion: 0.5 dB c
11、hange in optical transmittance during the test with 0.5 dB permanent change after test Humidity Resistance: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Wicking: Water Penetration of 88.5 mm maximum Fungus Resistance: Fungus inert per MIL-HDBK-454 Gu
12、ideline 4 Blocking: No areas of localized adhesion 4. Mechanical Cold Bend: 0.5 dB change in optical transmittance after test Cyclic Flex: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Test temps: -55 C, +25 C, +150 C Impact Resistance: 0.5 dB change
13、in optical transmittance during the test with 0.5 dB permanent change after test Test Cycles: 50 at -55 C, 100 at +25 C, 50 at +150 C Crush Resistance: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50
14、/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5 SHEET 3 OF 4 REV. A Corner Bend: 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Cable Tensile Load and 0.5 dB change in optical transmittance during the test with Bending: 0.5 dB permanen
15、t change after test Maximum tensile load 132 N Jacket Material Tensile Strength: 900 N/cm2minimum Tensile and Elongation: Elongation: 125% minimum Durability of Manufacturers Required unless identification marking is under a clear jacket Identification: Jacket Strippability: Easily Removed, No damag
16、e to Fiber at 10X 5. Thermal Flammability: After Flame: 30 seconds maximum Flame Travel: 3 inches maximum Tissue Flaming: None Thermal Shock: Temperature Range: -55 to +165 C Maximum Cable Diameter Change of 10% 0.5 dB change in optical transmittance after test Property Retention 750 h at 180 C Afte
17、r Thermal Aging: 300 h at 200 C 100 h at 220 C Maximum Cable Diameter Change of 10% 0.5 dB change in optical transmittance after test Jacket tensile and elongation: 75% of initial value Storage Life: Temperature Range: -55 to +85 C No Visual Damage at 10X Magnification 0.5 dB change in optical trans
18、mittance after test Temperature Cycling: 5 cycles, temperature range: -55 to +165 C Maximum Cable Diameter Change of 10% 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Temperature Cycling 5 cycles, temperature range: -55 to +165 C With Mandrel: Wrapped
19、 5 times around a 0.75 inch mandrel 0.5 dB change in optical transmittance during the test with 0.5 dB permanent change after test Jacket Shrinkage: 2.3 mm maximum in a 360 mm sample AEROSPACE STANDARD CABLE, FIBER OPTIC, MULTI-MODE, 50/125/450 m, GRADED INDEX, HERMETIC COATED, TIGHT BUFFER AS5382/5
20、 SHEET 4 OF 4 REV. A TABLE 1 - IMMERSION TEST FLUIDS TEST FLUID TEST TEMPERATURE IMMERSION TIMEMIL-PRF-23699, Lubricating Oil, Aircraft Turbine Engine, Synthetic Base 48 to 50 C 20 hours MIL-PRF-5606, Hydraulic Fluid, Petroleum Base, Aircraft, Missile and Ordnance 48 to 50 C 20 hours TT-I-735, Isopr
21、opyl Alcohol (Grade A or B) 20 to 25 C 168 hours MIL-DTL-5624, Turbine Fuel, Aviation, Grade JP-4 and JP-5 20 to 25 C 168 hours SAE AMS 1424, Deicing/Anti-Icing Fluid, Aircraft, SAE Type I Propylene Glycol Based 48 to 50 C 20 hours SAE AMS 1435, Fluid, Deicing/Anti-Icing, Runways and Taxiways 48 to
22、50 C 20 hours MIL-C-43616, Cleaning Compound, Aircraft Surface 48 to 50 C 20 hours ASTM D 1153, Methyl Isobutyl Ketone (for use in Organic Coatings) 20 to 25 C 168 hours MIL-PRF-7808, Lubricating Oil, Aircraft Turbine Engine, Synthetic Base 118 to 121 C 30 minutes MIL-PRF-85570, Type 3 Cleaning Comp
23、ound, Alkaline 63 to 68 C 20 hours MIL-PRF-87252, Coolant Fluid, Hydrolytically Stable, Dielectric (POA) 20 to 25 C 168 hours MIL-DTL-83133, Turbine Fuel, Aviation Grade, JP-8 20 to 25 C 168 hours MIL-PRF-83282, Hydraulic Fluid 48 to 50 C 20 hours Halon Bromotrifluoromethane (CFBR) 48 to 50 C 168 ho
24、urs Halon Bromotrifluoromethane (CFBR) -55 to -65 C 168 hours NOTES: THE CHANGE BAR ( l ) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT.