SAE AS 5756 4B-2014 CABLE ELECTRICAL 600 VOLTS PORTABLE MULTICONDUCTOR OZONE RESISTANT.pdf

上传人:priceawful190 文档编号:1024942 上传时间:2019-03-21 格式:PDF 页数:4 大小:143.53KB
下载 相关 举报
SAE AS 5756 4B-2014 CABLE ELECTRICAL 600 VOLTS PORTABLE MULTICONDUCTOR OZONE RESISTANT.pdf_第1页
第1页 / 共4页
SAE AS 5756 4B-2014 CABLE ELECTRICAL 600 VOLTS PORTABLE MULTICONDUCTOR OZONE RESISTANT.pdf_第2页
第2页 / 共4页
SAE AS 5756 4B-2014 CABLE ELECTRICAL 600 VOLTS PORTABLE MULTICONDUCTOR OZONE RESISTANT.pdf_第3页
第3页 / 共4页
SAE AS 5756 4B-2014 CABLE ELECTRICAL 600 VOLTS PORTABLE MULTICONDUCTOR OZONE RESISTANT.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AEROSPACE STANDARD CABLE, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR, OZONE RESISTANT AS5756/4Copyright 2014 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, ph

2、otocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-06REVISED 2014-12TH

3、IRD ANGLE PROJECTION CUSTODIAN: AE-8D REV.BFEDERAL SUPPLY CLASS 6145AS5756/4SHEET 1 OF 4REV. BPROCUREMENT SPECIFICATION: AS5756SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technicalandengineering sciences. Theuse ofthisreportis entirelyvolunt

4、ary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, is thesole responsibilityoftheuser.”SAE reviews eachtechnicalreport at least every five years at which time itmay berevised,reaffirmed, stabilized, orcancelled. SAE invites yourwritte

5、ncomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS5756_4BRATIONALE REVISION REQUIRED TO ADDRESS THE OUTER CABLE DIAMETERS. NOTICE THE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHAL

6、L CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS5756. FIGURE 1 EXAMPLE OF 3 CONDUCTOR CABLE REQUIREMENTS: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF A5756. QUALIFICATION: REQUIRED. CONSTRUCTION: (SEE TABLE 1) FIRST - COPPER CONDUCTOR, SEE TABLE 1 OF AS5756 FOR REQUI

7、REMENTS, SIZES 10 AWG AND SMALLER SHALL BE TIN-COATED, SIZES 8 AWG AND LARGER SHALL BE UNCOATED. SECOND - SEPARATOR, REQUIRED WHERE UNCOATED CONDUCTORS ARE USED, OPTIONAL WHERE TIN-COATED CONDUCTORS ARE USED. THIRD - INSULATION OF OZONE RESISTANT SYNTHETIC RUBBER (SEE TABLE 1 FOR THICKNESS), COLOR C

8、ODED PER 3.4.6 OF AS5756. FOURTH - THE REQUIRED NUMBER OF CONDUCTORS CABLED TOGETHER WITH A LEFT-HAND LAY NOT GREATER THAN 16 TIMES THE DIAMETER UNDER THE JACKET. WHEN NEEDED, FILLERS SHALL BE EMPLOYED TO OBTAIN A FIRM, WELL-ROUNDED ASSEMBLY. FIFTH - BINDER TAPE APPLIED HELICALLY WITH OVERLAP. SIXTH

9、 - JACKET OF OZONE RESISTANT SYNTHETIC RUBBER (SEE TABLE 1 FOR THICKNESS), COLORED BLACK. CABLE SURFACE MARKING REQUIRED. OZONE RESISTANCE: REQUIRED. AEROSPACE STANDARD AS5756/4SHEET 2 OF 4REV. BCABLE, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR, OZONE RESISTANT TABLE 1 - DETAILS OF CONSTRUCTION

10、 MILITARY PART NO. M5756/4 CONDUCTOR SIZE NUMBER OF CONDUCTORSNOMINAL INSULATIONTHICKNESS(INCH) 1/NOMINAL JACKET THICKNESS(INCH) 2/OVERALL DIAMETER OF JACKETED CABLECONDUCTOR RESISTANCE PER1000 FEET (MAX) 20 C (OHMS) NOMINAL WEIGHT PER1000 FEET (POUNDS)3/MIN (INCHES) MAX(INCHES) -001 18 2 .031 .0625

11、 .316 .395 7.49 60.9 -002 16 2 .031 .0625 .338 .419 4.70 72.5 -003 14 2 .047 .078 .429 .530 2.96 127.9 -004 12 2 .047 .078 .523 .600 1.86 159.3 -005 10 2 .047 .094 .549 .648 1.20 217.7 -006 8 2 .063 .109 .705 .824 .699 335.0 -007 6 2 .063 .125 .831 .962 .444 487.2 -008 4 2 .063 .141 .965 1.100 .279

12、676.9 -009 2 2 .063 .156 1.150 1.270 .177 945.1 -010 1 2 .078 .156 1.270 1.410 .141 1173.1 -011 1/0 2 .078 .172 1.360 1.540 .111 1422.5 -012 2/0 2 .078 .187 1.560 1.740 .0893 1780.0 -013 3/0 2 .078 .187 1.710 1.890 .0708 2131.3 -014 4/0 2 .078 .203 1.840 2.050 .0562 2586.6 -015 250 2 .094 .203 2.010

13、 2.220 .0476 3045.2 -016 18 3 .031 .0625 .331 .412 7.49 71.9 -017 16 3 .031 .0625 .356 .438 4.70 87.2 -018 14 3 .047 .078 .482 .557 2.96 154.0 -019 12 3 .047 .094 .587 .656 1.86 213.9 -020 10 3 .047 .094 .611 .692 1.20 268.9 -021 8 3 .063 .109 .772 .869 .699 429.9 -022 6 3 .063 .141 .910 1.100 .444

14、639.5 -023 4 3 .063 .156 1.050 1.190 .279 888.4 -024 2 3 .063 .172 1.270 1.370 .177 1252.9 -025 1 3 .078 .172 1.350 1.520 .141 1556.6 -026 1/0 3 .078 .172 1.480 1.630 .111 1837.1 -027 2/0 3 .078 .187 1.680 1.840 .0893 2295.1 -028 3/0 3 .078 .203 1.820 2.030 .0708 2832.2 -029 4/0 3 .078 .203 1.990 2.

15、180 .0562 3369.2 -030 250 3 .094 .203 2.140 2.360 .0476 3995.8 -031 18 4 .031 .0625 .358 .441 7.49 85.2 -032 16 4 .031 .0625 .385 .470 4.70 104.8 -033 14 4 .047 .078 .523 .601 2.96 185.6 -034 12 4 .047 .094 .633 .719 1.86 258.4 -035 10 4 .047 .109 .688 .773 1.20 349.2 1/ THE MINIMUM INSULATION THICK

16、NESS SHALL BE AT LEAST 90% OF THE NOMINAL. 2/ THE MINIMUM JACKET THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 3/ THE NOMINAL WEIGHT IS FOR INFORMATION ONLY. AEROSPACE STANDARD AS5756/4SHEET 3 OF 4REV. BCABLE, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR, OZONE RESISTANT TABLE 1 - DETAILS OF CO

17、NSTRUCTION (CONTINUED) MILITARY PART NO. M5756/4 CONDUCTOR SIZE NUMBER OF CONDUCTORSNOMINAL INSULATIONTHICKNESS(INCH) 1/NOMINAL JACKET THICKNESS(INCH) 2/OVERALL DIAMETER OF JACKETED CABLECONDUCTOR RESISTANCE PER1000 FEET (MAX) 20 C (OHMS) NOMINAL WEIGHT PER1000 FEET (POUNDS)3/MIN (INCHES) MAX(INCHES

18、) -036 8 4 .063 .109 .872 .975 .699 511.3 -037 6 4 .063 .125 1.020 1.140 .444 749.6 -038 4 4 .063 .156 1.170 1.300 .279 1095.5 -039 2 4 .063 .172 1.330 1.490 .177 1555.4 -040 1 4 .078 .172 1.510 1.660 .141 1941.6 -041 1/0 4 .078 .187 1.620 1.810 .111 2352.8 -042 2/0 4 .078 .203 1.840 2.050 .0893 293

19、6.5 -043 3/0 4 .078 .203 2.020 2.220 .0708 3554.9 -044 4/0 4 .078 .203 2.180 2.390 .0562 4246.3 -045 250 4 .094 .203 2.350 2.590 .0476 5052.8 -046 18 5 .031 .0625 .387 .472 7.49 99.5 -047 16 5 .031 .078 .417 .515 4.70 137.5 -048 14 5 .047 .094 .568 .682 2.96 238.5 -049 12 5 .047 .109 .700 .799 1.86

20、326.3 -050 10 5 .047 .109 .748 .842 1.20 413.6 -051 8 5 .063 .141 .948 1.090 .699 693.4 -052 6 5 .063 .156 1.140 1.260 .444 968.6 -053 4 5 .063 .156 1.280 1.410 .279 1311.4 -054 2 5 .063 .172 1.480 1.620 .177 1869.4 -055 1 5 .078 .187 1.680 1.840 .141 2392.9 -056 1/0 5 .078 .203 1.800 2.010 .111 289

21、9.6 -057 2/0 5 .078 .203 2.050 2.240 .0893 3544.5 -058 3/0 5 .078 .203 2.220 2.430 .0708 4303.7 -059 4/0 5 .078 .203 2.400 2.620 .0562 5153.9 -060 250 5 .094 .203 2.590 2.840 .0476 6122.6 -061 18 6 .031 .078 .417 .516 7.49 128.0 -062 16 6 .031 .078 .479 .556 4.70 157.0 -063 14 6 .047 .094 .646 .734

22、2.96 273.2 -064 12 6 .047 .109 .749 .873 1.86 374.3 -065 10 6 .047 .125 .810 .940 1.20 505.0 -066 8 6 .063 .156 1.060 1.210 .699 833.2 -067 6 6 .063 .156 1.230 1.370 .444 1120.4 -068 4 6 .063 .172 1.420 1.560 .279 1571.8 -069 2 6 .063 .187 1.610 1.790 .177 2231.6 -070 1 6 .078 .203 1.830 2.030 .141

23、2855.0 1/ THE MINIMUM INSULATION THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 2/ THE MINIMUM JACKET THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 3/ THE NOMINAL WEIGHT IS FOR INFORMATION ONLY. AEROSPACE STANDARD AS5756/4SHEET 4 OF 4REV. BCABLE, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR, O

24、ZONE RESISTANT TABLE 1 - DETAILS OF CONSTRUCTION (CONTINUED) MILITARY PART NO. M5756/4 CONDUCTORSIZE NUMBER OF CONDUCTORS NOMINAL INSULATIONTHICKNESS(INCH) 1/NOMINAL JACKET THICKNESS(INCH) 2/OVERALL DIAMETER OF JACKETED CABLECONDUCTOR RESISTANCE PER1000 FEET (MAX) 20 C (OHMS) NOMINAL WEIGHT PER1000

25、FEET (POUNDS)3/MIN (INCHES) MAX(INCHES) -071 1/0 6 .078 .203 1.990 2.180 .111 3388.0 -072 2/0 6 .078 .203 2.330 2.440 .0893 4147.1 -073 3/0 6 .078 .203 2.430 2.650 .0708 5046.1 -074 4/0 6 .078 .203 2.620 2.860 .0562 6053.0 -075 250 6 .094 .203 2.840 3.100 .0476 7227.5 -076 18 7 .031 .078 .417 .516 7

26、.49 138.9 -077 16 7 .031 .078 .479 .556 4.70 172.0 -078 14 7 .047 .094 .646 .734 2.96 300.3 -079 12 7 .047 .109 .709 .833 1.86 412.4 -080 10 7 .047 .125 .810 .940 1.20 557.8 -081 8 7 .063 .156 1.060 1.210 .699 921.6 -082 6 7 .063 .156 1.230 1.370 .444 1249.0 -083 4 7 .063 .172 1.420 1.560 .279 1760.

27、2 -084 2 7 .063 .187 1.610 1.790 .177 2511.0 -085 1 7 .078 .203 1.830 2.030 .141 3216.5 -086 1/0 7 .078 .203 1.990 2.180 .111 3829.7 -087 2/0 7 .078 .203 2.230 2.440 .0893 4699.9 -088 3/0 7 .078 .203 2.430 2.650 .0708 5736.5 -089 4/0 7 .078 .203 2.620 2.860 .0562 6898.8 -090 250 7 .094 .203 2.840 3.

28、100 .0476 8255.3 1/ THE MINIMUM INSULATION THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 2/ THE MINIMUM JACKET THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 3/ THE NOMINAL WEIGHT IS FOR INFORMATION ONLY. NOTES: 1. THE INSULATING AND JACKETING MATERIALS SHALL BE RESISTANT TO DEGRADATION DUE TO SU

29、NLIGHT, OZONE, AND OTHER FORMS OF WEATHERING EXPOSURE. THIS CABLE IS DESIGNED TO BE SUITABLE FOR USE WHERE IT MAY BE EXPOSED TO THESE CONDITIONS. 2. CABLES COVERED UNDER THIS SPECIFICATION SHEET ARE DESIGNED FOR USE IN CABLE ASSEMBLIES CONFORMING TO AS7974. THESE CABLES ARE SUITABLE ALTERNATIVES FOR

30、 MULTICONDUCTOR CABLES SPECIFIED IN AS5756B. 3. EXAMPLES OF TYPICAL INSULATING AND JACKETING MATERIALS INCLUDE ETHYLENE PROPYLENE RUBBER (EPR) AND POLYCHLOROPRENE, RESPECTIVELY. 4. A CHANGE BAR (l) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISI

31、ONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1