1、 AEROSPACE STANDARD CONNECTORS, ELECTRICAL, RECTANGULAR, RECEPTACLE, CRIMP CONTACTS, (SINGLE INSERT, TYPE IV, CLASS 1, (-65 C TO +125 C), SERIES 2, SHELL DESIGNATOR A, FLOAT MOUNTING) AS81659/68Copyright 2017 SAE International All rights reserved. No part of this publication may be reproduced, store
2、d in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 E
3、mail: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED2004-05REVISED2017-06THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8C1 REV.BFEDERAL SUPPLY CLASS 5935 AS81659/68 SHEET 1 OF 4 REV. B PROCUREMENT SPECIFICATION: AS81659 SAETechnicalStandardsBoard Rulesprovidethat:“Thisreportispublished
4、 bySAEto advance the state oftechnicaland engineering sciences.The use ofthisreportisentirelyvoluntary,anditsapplicabilityandsuitabilityforanyparticularuse,includinganypatentinfringementarising therefrom,isthe sole responsibilityoftheuser.”SAEreviewseachtechnicalreportatleasteveryfiveyearsatwhich ti
5、me itmaybe revised,reaffirmed,stabilized,orcancelled.SAEinvitesyourwritten commentsandsuggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS81659/68B RATIONALE REVISION IS REQUIRED TO UPDATE THE CONNECTOR INSERT AND INSTALLING/REMOVAL
6、 TOOL REFERENCES. FIGURE 1 - CONNECTOR SUGGESTED PANEL CUTOUT/RECOMMENDED MATED POSITION INCH MM INCH MM INCH MM INCHES MM INCHES MM .005 .006 .015 .023 .025 .027 .037 .040 .047 .13 .15 .38 .58 .64 .69 .94 1.02 1.19 .050 .055 .060 .065 .117 .118 .122 .133 .178 1.27 1.40 1.52 1.65 2.97 3.00 3.10 3.38
7、 4.52 .198 .245 .255 .421 .467 .521 .541 .570 .7185 .928 5.03 6.22 6.48 10.69 11.86 13.23 13.74 14.48 18.25 23.57 .948 1.000 1.326 1.367 1.387 1.425 1.427 1.437 1.447 24.08 25.40 33.68 34.72 35.23 36.20 36.25 36.50 36.75 1.475 1.720 1.725 1.765 1.815 1.985 1.997 2.015 2.027 2.250 37.46 43.69 43.82 4
8、4.83 46.10 50.42 50.72 51.18 51.49 57.15 AEROSPACE STANDARD AS81659/68 SHEET 2 OF 4 REV. B CONNECTORS, ELECTRICAL, RECTANGULAR, RECEPTACLE, CRIMP CONTACTS, (SINGLE INSERT, TYPE IV, CLASS 1, (-65 C TO +125 C), SERIES 2, SHELL DESIGNATOR A, FLOAT MOUNTING) FIGURE 2 - CONNECTOR CONFIGURATIONS AND DIMEN
9、SIONS AEROSPACE STANDARD AS81659/68 SHEET 3 OF 4 REV. B CONNECTORS, ELECTRICAL, RECTANGULAR, RECEPTACLE, CRIMP CONTACTS, (SINGLE INSERT, TYPE IV, CLASS 1, (-65 C TO +125 C), SERIES 2, SHELL DESIGNATOR A, FLOAT MOUNTING) FIGURE 2 - CONNECTOR CONFIGURATIONS AND DIMENSIONS (CONTINUED) AEROSPACE STANDAR
10、D AS81659/68 SHEET 4 OF 4 REV. B CONNECTORS, ELECTRICAL, RECTANGULAR, RECEPTACLE, CRIMP CONTACTS, (SINGLE INSERT, TYPE IV, CLASS 1, (-65 C TO +125 C), SERIES 2, SHELL DESIGNATOR A, FLOAT MOUNTING) REQUIREMENTS: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS81659. 1. DESIG
11、N: CONNECTOR ACCESSORIES SHALL BE DESIGNED IN ACCORDANCE WITH FIGURES 1 AND 2. DIMENSIONS ARE IN INCHES AND APPLY AFTER PLATING. TOLERANCES: DECIMALS .010 UNLESS OTHERWISE SPECIFIED. METRIC EQUIVALENTS ARE GIVEN FOR GENERAL INFORMATION ONLY AND ARE BASED UPON 1 INCH = 25.4 MM. NORMAL (01) POLARIZATI
12、ON POSITION SHOWN, FOR ALTERNATE POSITIONS SEE AS81659. FOR LOCATION OF DATUMS G AND H, REFER TO AS81659, FIGURE 5. THIS CONNECTOR DOES NOT HAVE A WIRE SEALING GROMMET. 2. INSERT ARRANGEMENTS SHALL BE IN ACCORDANCE WITH AS31571. 3. CONTACTS SHALL BE IN ACCORDANCE WITH AS39029/11 OR AS39029/12, AS AP
13、PLICABLE. 4. INSTALLING AND REMOVAL TOOLS SHALL BE IN ACCORDANCE WITH AS81969/1 OR AS81969/14. SPECIFICATION NOTES 1. REVISION INDICATOR: A CHANGE BAR (I) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.