1、 AEROSPACE STANDARD CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FREQUENCY ABSORPTIVE, 150C, 600-VOLT AS85485/12 Copyright 2004 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, e
2、lectronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: custsvcsae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2004-06THI
3、RD ANGLE PROJECTION CUSTODIAN: SAE AE-8/AE-8D FEDERAL SUPPLY CLASS6145 AS85485/12SHEET 1 OF 4 PROCUREMENT SPECIFICATION: MIL-C-85485SAE TechnicalStandards Board Rules provide that: “This report is published by SAE toadvance thestate of technical andengineering sciences. Theuse of thisreport is entir
4、ely voluntary, andits applicabilityandsuitability forany particularuse,including any patent infringement arising therefrom, is thesole responsibility oftheuser.” SAE reviews each technical report at least every five yearsat which time it may be reaffirmed, revised, orcancelled.SAE invites yourwritte
5、n commentsandsuggestions. NOTICE THIS DOCUMENT HAS BEEN TAKEN DIRECTLY FROM U.S. MILITARY SPECIFICATION MIL-C-85485/12 AND CONTAINS ONLY MINOR EDITORIAL AND FORMAT CHANGES REQUIRED TO BRING IT INTO CONFORMANCE WITH THE PUBLISHING REQUIREMENTS OF SAE TECHNICAL STANDARDS. THE INITIAL RELEASE OF THIS D
6、OCUMENT IS INTENDED TO REPLACE MIL-C-85485/12. ANY PART NUMBERS ESTABLISHED BY THE ORIGINAL SPECIFICATION REMAIN UNCHANGED. THE ORIGINAL MILITARY SPECIFICATION WAS ADOPTED AS AN SAE STANDARD UNDER THE PROVISIONS OF THE SAE TECHNICAL STANDARDS BOARD (TSB) RULES AND REGULATIONS (TSB 001) PERTAINING TO
7、 ACCELERATED ADOPTION OF GOVERNMENT SPECIFICATIONS AND STANDARDS. TSB RULES PROVIDE FOR (A) THE PUBLICATION OF PORTIONS OF UNREVISED GOVERNMENT SPECIFICATIONS AND STANDARDS WITHOUT CONSENSUS VOTING AT THE SAE COMMITTEE LEVEL, AND (B) THE USE OF THE EXISTING GOVERNMENT SPECIFICATION OR STANDARD FORMA
8、T. UNDER DEPARTMENT OF DEFENSE POLICIES AND PROCEDURES, ANY QUALIFICATION REQUIREMENTS AND ASSOCIATED QUALIFIED PRODUCTS LISTS ARE MANDATORY FOR DOD CONTRACTS. ANY REQUIREMENT RELATING TO QUALIFIED PRODUCTS LISTS (QPLS) HAS NOT BEEN ADOPTED BY SAE AND IS NOT PART OF THIS TECHNICAL REPORT. Copyright
9、SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FREQUENCY ABSORPTIVE, 150C, 600-VOLT AS85485/12 AS85485/12SHEET 2 OF 4 FIGURE 1. TYPIC
10、AL CONFIGURATION RATINGS: TEMPERATURE RATING: 150C (302F) MAXIMUM CONTINUOUS CONDUCTOR TEMPERATURE. VOLTAGE RATING: 600 VOLTS (RMS) AT SEA LEVEL. ADDITIONAL REQUIREMENTS: ATTENUATION (INSERTION LOSS): CONSULT QPL SOURCE FOR DETAILS. BLOCKING: 200 3C (392 5F) FOR 6 HOURS COLOR STRIPING DURABILITY: 12
11、5 CYCLES (250 STROKES) (MIN), 500 GRAMS WEIGHT. CROSSLINKING PROOF TEST: 7 HOURS AT 300 3C (572 5F). FLAMMABILITY: 3 SECONDS (MAX); 3 INCHES (MAX). IDENTIFICATION DURABILITY: 125 CYCLES (250 STROKES) (MIN), 500 GRAMS WEIGHT. IMMERSION: DIAMETER INCREASE 5% (MAX); NO CRACKING OF JACKET. JACKET COLOR:
12、 BLACK JACKET CONCENTRICITY: 70% (MIN) JACKET ELONGATION AND TENSILE STRENGTH: ELONGATION, 50% (MIN) TENSILE STRENGTH, 3500 LBF/IN2(MIN) JACKET FLAWS: NOT APPLICABLE. LIFE CYCLE: 168 HOURS AT 200 3C (392 5F) LOW TEMPERATURE-COLD BEND: -65 2C (-85 4F) FOR 4 HOURS SHIELD COVERAGE AND ANGLE: 85% (MIN)
13、COVERAGE; 18 (MIN), 40 (MAX) ANGLE SHIELD SIZE: 38 AWG ROUND WIRE STRANDS Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FR
14、EQUENCY ABSORPTIVE, 150C, 600-VOLT AS85485/12 AS85485/12SHEET 3 OF 4 SURFACE TRANSFER IMPEDANCE, EFFECTIVE: CONSULT QPL SOURCE FOR DETAILS. THERMAL SHOCK RESISTANCE: OVEN TEMPERATURE, 150 3C (302 5F) MAXIMUM CHANGE IN MEASUREMENT, 0.125 INCH THERMAL STABILITY: 1250 HOURS AT 180 3C (356 5F). VOLTAGE
15、WITHSTAND (DIELECTRIC) - NO BREAKDOWN. SHALL MEET STOP BAND ATTENUATION REQUIREMENTS FOR THE APPLICABLE COMPONENT WIRE SIZE AND NUMBER OF COMPONENTS. CONSULT QPL SOURCE FOR DETAILS. VOLTAGE WITHSTAND (DIELECTRIC): CONDUCTOR TO SHIELD, 1500 VOLTS (RMS), 60 HZ VOLTAGE WITHSTAND (POST-ENVIRONMENTAL): N
16、OT APPLICABLE. TABLE I. CONSTRUCTION DETAILS Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FREQUENCY ABSORPTIVE, 150C, 600
17、-VOLT AS85485/12 AS85485/12SHEET 4 OF 4 FIGURE 2. SURFACE TRANSFER IMPEDANCE, EFFECTIVE ENGINEERING REFERENCE CURVE QUALIFYING ACTIVITY: THE ACTIVITY RESPONSIBLE FOR THIS QUALIFIED PRODUCTS LIST IS THE NAVAL AIR SYSTEMS COMMAND, WASHINGTON, D.C. 20361. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-