SAE AS 95234 12-2014 CONNECTOR RECEPTACLE REVERSE BAYONET COUPLING DUMMY STOWAGE《虚拟装载反卡口连接的连接器插座》.pdf

上传人:sumcourage256 文档编号:1025897 上传时间:2019-03-21 格式:PDF 页数:4 大小:99.80KB
下载 相关 举报
SAE AS 95234 12-2014 CONNECTOR RECEPTACLE REVERSE BAYONET COUPLING DUMMY STOWAGE《虚拟装载反卡口连接的连接器插座》.pdf_第1页
第1页 / 共4页
SAE AS 95234 12-2014 CONNECTOR RECEPTACLE REVERSE BAYONET COUPLING DUMMY STOWAGE《虚拟装载反卡口连接的连接器插座》.pdf_第2页
第2页 / 共4页
SAE AS 95234 12-2014 CONNECTOR RECEPTACLE REVERSE BAYONET COUPLING DUMMY STOWAGE《虚拟装载反卡口连接的连接器插座》.pdf_第3页
第3页 / 共4页
SAE AS 95234 12-2014 CONNECTOR RECEPTACLE REVERSE BAYONET COUPLING DUMMY STOWAGE《虚拟装载反卡口连接的连接器插座》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AEROSPACE STANDARD CONNECTOR RECEPTACLE, REVERSE BAYONET COUPLING, DUMMY STOWAGE AS95234/12Copyright 2014 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopyi

2、ng, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED2014-07THIRD ANGLE PROJECTION CUS

3、TODIAN: AE-8/AE-8C1 FEDERAL SUPPLY CLASS 5935 AS95234/12SHEET 1 OF 4PROCUREMENT SPECIFICATION: AS95234SAE Technical Standards Board Rules provide that: “This report is publishedbySAEtoadvance thestateoftechnical and engineeringsciences. The useofthis reportisentirely voluntary, and its applicability

4、and suitability for any particularuse, includingany patent infringement arising therefrom, isthe soleresponsibility of the user.”SAE reviews each technical report at least every five years at whichtime it mayberevised, reaffirmed, stabilized, or cancelled. SAE invites your writtencomments and sugges

5、tions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS95234/12RATIONALE THIS DETAIL SPECIFICATION SHEET IS REQUIRED TO STANDARDIZE COMMERCIAL CONNECTORS FOR USER APPLICATIONS. NOTICE THE COMPLETE REQUIREMENTS FOR PROCURING THE

6、 PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS95234. FIGURE 1 - CONNECTOR DUMMY STOWAGE RECEPTACLE AEROSPACE STANDARD AS95234/12SHEET 2 OF 4CONNECTOR RECEPTACLE, REVERSE BAYONET COUPLING, DUMMY STOWAGE TABLE 1 - FIGURE 1 DIMENSIONS SHELLSIZEFRONT VIEW SIDE VIEW R

7、.004 (0.1) S.012 (0.3) T1 +.004/-.000 (+0.1/-0.0) A+.000/-.006 (+0.00/-0.15) K.008 (0.2) M+.016/-.000 (+0.4/-0.00 10SL .717 (18.2) 1.000 (25.4) .126 (3.2) .717 (18.2) .110 (2.8) .559 (14.2) 14S .906 (23.0) 1.181 (30.0) .126 (3.2) .969 (24.6) .126 (3.2) .559 (14.2) 16S .969 (24.6) 1.280 (32.5) .126 (

8、3.2) 1.079 (27.4) .126 (3.2) .559 (14.2) 16 .969 (24.6) 1.280 (32.5) .126 (3.2) 1.079 (27.4) .126 (3.2) .748 (19.0) 18 1.063 (27.0) 1.378 (35.0) .126 (3.2) 1.213 (30.8) .157 (4.0) .748 (19.0) 20 1.157 (29.4) 1.496 (38.0) .126 (3.2) 1.346 (34.2) .157 (4.0) .748 (19.0) 22 1.252 (31.8) 1.614 (41.0) .12

9、6 (3.2) 1.472 (37.4) .157 (4.0) .768 (19.5) 24 1.374 (34.9) 1.752 (44.5) .146 (3.7) 1.610 (40.9) .157 (4.0) .811 (20.6) 28 1.563 (39.7) 2.000 (50.8) .146 (3.7) 1.839 (46.7) .157 (4.0) .811 (20.6) 32 1.752 (44.5) 2.244 (57.0) .169 (4.3) 2.102 (53.4) .157 (4.0) .874 (22.2) 36 1.937 (49.2) 2.500 (63.5)

10、 .169 (4.3) 2.346 (59.6) .157 (4.0) .874 (22.2) SIDE VIEW-SECTIONED FIGURE 2 - CONNECTOR DUMMY STOWAGE RECEPTACLE (SIDE VIEW-SECTIONED) TABLE 2 - FIGURE 2 DIMENSIONS SHELLSIZESIDE VIEW B+.015/-.000 (+0.38/-0.00) D.008 (0.2) 10SL .448 (11.38) .572 (14.53) 14S .678 (17.22) .572 (14.53) 16S .808 (20.52

11、) .572 (14.53) 16 .808 (20.52) .750 (19.05) 18 .933 (23.69) .750 (19.05) 20 1.053 (26.75) .750 (19.05) 22 1.178 (29.92) .750 (19.05) 24 1.303 (33.09) .750 (19.05) 28 1.523 (38.68) .750 (19.05) 32 1.773 (45.03) .750 (19.05) 36 1.985 (50.41) .750 (19.05) AEROSPACE STANDARD AS95234/12SHEET 3 OF 4CONNEC

12、TOR RECEPTACLE, REVERSE BAYONET COUPLING, DUMMY STOWAGE REQUIREMENTS: ALL REQUIREMENTS SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS95234. 1. DESIGN: CONNECTORS SHALL BE DESIGNED IN ACCORDANCE WTH FIGURE 1 AND TABLE 1. DIMENSIONS ARE IN INCHES. METRIC EQUIVALENTS ARE GIVEN FOR INFORMATIO

13、N ONLY AND ARE BASED ON 1 INCH = 25.4 MM. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE .016 INCHES. MATING INTERFACE DIMENSIONS SHALL BE AS REQUIRED IN AS95234. 2. CORROSION (SALT SPRAY): COVERS SHALL MEET THE REQUIREMENT OF AIR4789. 3. FINISH AVAILABILITY: SEE TABLE 3. TABLE 3 - FINISH FINISH CODE FI

14、NISH DESCRIPTION W CADMIUM OLIVE DRAB OVER SUITABLE UNDERPLATE AND DESIGNED TO WITHSTAND 500 HOUR SALT SPRAY TESTING. A BLACK ANODIZE PER AMS-A-8625, TYPE II, CLASS 2 AND DESIGNED TO WITHSTAND 500 HOUR SALT SPRAY TESTING. XNICKEL FLUOROCARBON POLYMER IN ACCORDANCE WITH AMS2454 OVER A SUITABLE UNDERP

15、LATE. FINISH SHALL BE NON-REFLECTIVE AND ELECTRICALLY CONDUCTIVE AND DESIGNED TO WITHSTAND 500 HOUR SALT SPRAY TESTING. YPURE DENSE ELECTRODEPOSITED ALUMINUM IN ACCORDANCE WITH MIL-DTL-83488, TYPE II. FINAL FINISH SHALL BE NON-REFLECTIVE AND ELECTRICALLY CONDUCTIVE AND DESIGNED TO WITHSTAND 500 HOUR

16、 SALT SPRAY TESTING. ZZINC NICKEL IN ACCORDANCE WITH ASTM B841 OVER SUITABLE UNDERPLATE. FINAL FINISH SHALL BE BLACK AND ELECTRICALLY CONDUCTIVE AND DESIGNED TO WITHSTAND 500 HOUR SALT SPRAY TESTING. . B BLACK CADMIUM IN ACCORDANCE WITH AMS-QQ-P-416, TYPE II, CLASS 3, AND DESIGNED TO WITHSTAND 500 H

17、OUR SALT SPRAY TESTING. S PASSIVATED IN ACCORDANCE WITH AMS-QQ-P-35, ASTM A967, OR AMS2700, AND DESIGN TO WITHSTAND 500 HOUR SALT SPRAY TESTING. XSNICKEL WITH FLUOROCARBON POLYMER ADDITIVES OVER A SUITABLE UNDERPLATE TO WITHSTAND 500 HOURS OF SALT SPRAY TESTING. COLOR SHALL BE NON-REFLECTIVE. FINAL

18、FINISH SHALL BE ELECTRICALLY CONDUCTIVE. YS PURE DENSE ELECTRODEPOSITED ALUMINUM IN ACCORDANCE WITH MIL-DTL-83488, TYPE II, TO WITHSTAND 500 HOURS OF SALT SPRAY TESTING. COLOR SHALL BE NON-REFLECTIVE. FINAL FINISH SHALL BE ELECTRICALLY CONDUCTIVE ZSZINC NICKEL IN ACCORDANCE WITH ASTM B841 OVER SUITA

19、BLE UNDERPLATE. FINAL FINISH SHALL BE BLACK, ELECTRICALLY CONDUCTIVE AND DESIGNED TO WITHSTAND 500 HOUR SALT SPRAY TESTING. 4. QUALIFICATION: INITIAL QUALIFICATION SHALL BE PERFORMED SEQUENTIALLY IN ACCORDANCE WITH TABLE 4 ON TWO (2) SMALL, MEDIUM, AND LARGE SHELL SIZE SPECIMENS (SEE TABLE 1). TEST

20、SPECIMENS SHALL CONSIST OF EACH FINISH FOR WHICH QUALIFICATION IS DESIRED (SEE TABLE 2). a. QUALIFICATION BY SIMILARITY WITHOUT TESTING SHALL BE COMPARED TO THE SPECIFICATION DIMENSIONS (CERTIFICATION OF COMPLIANCE IS REQUIRED). b. PERIODIC QUALIFICATION SHALL BE PERFORMED EVERY 36 MONTHS AFTER INIT

21、IAL QUALIFICATION UNLESS SUBMITTAL DATE IS ADJUSTED BY THE QUALIFYING ACTIVITY (SEE APPLICATION NOTE). CORROSION TEST REQUIRED FOR INITIAL QUALIFICATION AND EVERY OTHER RETENTION CYCLE THEREAFTER. AEROSPACE STANDARD AS95234/12SHEET 4 OF 4CONNECTOR RECEPTACLE, REVERSE BAYONET COUPLING, DUMMY STOWAGE

22、TABLE 4 - QUALIFICATION AND QUALITY ASSURANCE (QA) TESTS QUALIFICATION TESTS REQUIREMENT TEST METHOD QC TESTS QA PERFORMEDTESTS CONSTRUCTION 1 VISUAL EXAMINATION REQUIRED X DIMENSIONS FIGURE 1 & TABLE 1 MEASURE & RECORD REQUIRED X MATERIALS 2 CERTIFICATION FINISH 4 & TABLE 2 CERTIFICATION CORROSION

23、7 (SEE AIR4789) EIA 364-26 TEST CONDITION C X 5. QUALITY CONFORMANCE (QC) TESTS: a. INSPECTION LOT: AN INSPECTION LOT SHALL CONSIST OF ALL COVERS OF THE SAME TYPE PRODUCED UNDER ESSENTIALLY THE SAME CONDITIONS, AND OFFERED FOR INSPECTION AT ONE TIME. b. SAMPLING PLAN: STATISTICAL SAMPLING AND INSPEC

24、TION SHALL BE IN ACCORDANCE WITH ANSI/ASQ Z1.4 FOR GENERAL INSPECTION LEVEL II. THE ACCEPTABLE QUALITY LEVEL (AQL) SHALL BE 1.0 FOR MAJOR DEFECTS AND 4.0 FOR MINOR DEFECTS. MAJOR AND MINOR DEFECTS SHALL BE AS DEFINED IN MIL-STD-1916 OR ANSI/ASQ Z1.4. c. REJECTED LOTS: IF AN INSPECTION LOT IS REJECTE

25、D, THE CONTRACTOR MAY REWORK IT TO CORRECT THE DEFECTS, OR SCREEN OUT THE DEFECTIVE UNITS AND RESUBMIT FOR INSPECTION. RESUBMITTED LOTS SHALL BE INSPECTED IN ACCORDANCE WITH ANSI/ASQ Z1.4, TIGHTENED INSPECTION. SUCH LOTS SHALL BE SEPARATE FROM NEW LOTS AND SHALL BE CLEARLY IDENTIFIED AS INSPECTED LO

26、TS. THE CONTRACTOR SHALL NOTIFY THE QUALIFYING ACTIVITY IMMEDIATELY OF ANY QUALITY CONFORMANCE INSPECTION FAILURES WHICH RESULT IN A CHANGE IN CONTROL DRAWINGS OR PROCESS CONTROL INSPECTION POINTS. FAILURE TO NOTIFY THE QUALIFYING ACTIVITY MAY RESULT IN LOSS OF QUALIFICATION OF THAT PRODUCT. d. DISP

27、OSITION OF SAMPLE UNITS: SAMPLE UNITS WHICH HAVE PASSED QUALITY CONFORMANCE INSPECTION MAY BE DELIVERED ON THE CONTRACT IF THE LOT IS ACCEPTED AND THE SAMPLE UNITS ARE STILL WITHIN SPECIFIED TOLERANCES. 6. PART NUMBER: THE PART NUMBER SHALL BE AS SHOWN IN THE EXAMPLE BELOW: AS95234 /12 W 16 BASIC SP

28、ECIFICATION DETAIL SHEET FINISH (SEE TABLE 3) SHELL SIZE (SEE TABLE 1) SPECIFICATION NOTES: NOTICE THIS DOCUMENT REFERENCES A PART WHICH CONTAINS CADMIUM AS A PLATING MATERIAL. CONSULT LOCAL OFFICIALS IF YOU HAVE QUESTIONS CONCERNING CADMIUMS USE. 1. A CHANGE BAR (l) LOCATED IN THE LEFT MARGIN IS FO

29、R THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDICATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1