资源描述

1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro

2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (724) 772-8512 FAX: (724) 776-0243TO PLACE A DOCUMENT

3、 ORDER; (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1971 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001RECOMMENDEDPRACTICESubmitted for recognition as an American National Sta

4、ndardJ259ISSUEDJUN71Issued 1971-06IGNITION SWITCHForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.1. Scope2. ReferencesThere are no referenced publications specified herein.3. Definitions3.1 Ignition SwitchPart of an electrical system by whi

5、ch the operator of a vehicle causes the ignition system tofunction. In addition to ignition circuitry, the switch may have circuits which control electrical accessories,engine starting, warning indicator lamp checking, etc.4. Temperature Test4.1 To insure basic function, the switch shall be manually

6、 cycled for 10 cycles at design electrical load at24 5.5 C (75 10 F), 74 +0, 2.8 C (165 +0, 5 F), and 32 +2.8, 0 C (25 +5, 0 F ) after a 1 hexposure at each of these temperatures. The switch shall be electrically and mechanically operable duringeach of these cycles.4.2 This same switch shall be used

7、 for the endurance test described below.5. Endurance Test Setup5.1 The switch shall be set up to operate its design electrical load.5.2 The test shall be set up to operate the switch for the prescribed number of complete cycles.One complete cycle shall consist of sequencing through each position (wi

8、th dwell in each position) and returnwithout dwell in intermediate positions to the initial position.The test requirements shall be so arranged as to provide the following mechanical time requirements:Travel Time0.10.5 s (time from one position to the next).Dwell Time1.02.0 s (time in each position)

9、SAE J259 Issued JUN71-2-5.3 During the test the switch shall be operated at:6.4 V d-c for a 6 V system12.8 V d-c for a 12 V system25.6 V d-c for a 24 V systemThese voltages shall be measured at the input termination on the switch.The power supply shall not generate any adverse transients not presen

10、t in motor vehicles and shall complywith the following specifications:a. Output CurrentCapable of supplying the continuous current of the design electrical load.b. RegulationDynamicThe output voltage at the supply shall not deviate more than 1.0 V from zero to maximumload (including inrush current)

11、and should recover 63% of its maximum excursion within 100 ms.StaticThe output voltage at the supply shall not deviate more than 2% with changes in static loadfrom zero to maximum (not including inrush current), and means shall be provided to compensate forstatic input line voltage variations.c. Rip

12、ple VoltageMaximum 300 mV peak to peak.6. Endurance Requirements6.1 The switch shall be capable of satisfactory operating for 25,000 complete cycles at a temperature of24 5.5 C (75 10 F).6.2 When the switch has a position which operates accessories only, the switch shall be cycled to that positiondu

13、ring 25% of the endurance cycles.6.3 The voltage drop from the input terminal(s) to the corresponding output terminal(s) shall be measured beforeand after the endurance test and shall not exceed 0.30 V (the average of three consecutive readings) at 10.0 Aexcept in circuits such as warning indicator

14、lamp checking and/or grounding type circuits which do not exceed1 A load. In these circuits, the voltage drop shall not exceed 0.50 V (the average of three consecutivereadings) at 1.0 A. If wiring is an integral part of the switch, the voltage drop measurement shall be madeincluding 3 in. of wire on

15、 each side of the switch; otherwise, measurement shall be made at switch terminals.PREPARED BY THE SAE ELECTRICAL EQUIPMENT COMMITTEESAE J259 Issued JUN71RationaleNot applicable.Relationship of SAE Standard to ISO StandardNot applicable.ApplicationNot applicable.Reference SectionThere are no referenced publications specified herein.Developed by the SAE Electrical Equipment Committee

展开阅读全文
相关资源
猜你喜欢
  • DIN 6844-2-2005 Nuclear medicine departments - Part 2 Rules for the installation and equipment for therapeutic applications of unsealed radioactive sources《核医疗部门 第2部分 非密封放射源的治疗应用装置.pdf DIN 6844-2-2005 Nuclear medicine departments - Part 2 Rules for the installation and equipment for therapeutic applications of unsealed radioactive sources《核医疗部门 第2部分 非密封放射源的治疗应用装置.pdf
  • DIN 6844-3 Berichtigung 1-2007 Nuclear medicine departments - Part 3 Radiation protection calculations Corrigenda to DIN 6844-3 2006-12《核医学部门 第3部分 辐射防护计算 DIN 6844-3-2006》.pdf DIN 6844-3 Berichtigung 1-2007 Nuclear medicine departments - Part 3 Radiation protection calculations Corrigenda to DIN 6844-3 2006-12《核医学部门 第3部分 辐射防护计算 DIN 6844-3-2006》.pdf
  • DIN 6844-3-2006 Nuclear medicine departments - Part 3 Radiation protection calculations《核医疗部门 第3部分 辐射防护计算》.pdf DIN 6844-3-2006 Nuclear medicine departments - Part 3 Radiation protection calculations《核医疗部门 第3部分 辐射防护计算》.pdf
  • DIN 6846-2-2003 Medical teletherapy systems with gamma-emitting sources - Part 2 Radiation safety requirements for installation《带γ射线源的放射治疗系统 第2部分 辐射安全要求》.pdf DIN 6846-2-2003 Medical teletherapy systems with gamma-emitting sources - Part 2 Radiation safety requirements for installation《带γ射线源的放射治疗系统 第2部分 辐射安全要求》.pdf
  • DIN 6846-5-1992 Medical teletherapy systems with gamma-emitting sources constancy testing《带γ放射源的医用放射疗设备 稳定性检验》.pdf DIN 6846-5-1992 Medical teletherapy systems with gamma-emitting sources constancy testing《带γ放射源的医用放射疗设备 稳定性检验》.pdf
  • DIN 6847-2-2014 Medical electron accelerators - Part 2 Rules for construction of structural radiation protection《医疗电子加速器 第2部分 结构辐射防护的构造规则》.pdf DIN 6847-2-2014 Medical electron accelerators - Part 2 Rules for construction of structural radiation protection《医疗电子加速器 第2部分 结构辐射防护的构造规则》.pdf
  • DIN 6847-5 Berichtigung 1-2015 Medical electron accelerators - Part 5 Constancy tests of functional performance characteristics Corrigendum to DIN 6847-5 2013-10《医疗电子加速器 第5部分 功能性能特.pdf DIN 6847-5 Berichtigung 1-2015 Medical electron accelerators - Part 5 Constancy tests of functional performance characteristics Corrigendum to DIN 6847-5 2013-10《医疗电子加速器 第5部分 功能性能特.pdf
  • DIN 6847-5-2013 Medical electron accelerators - Part 5 Constancy tests of functional performance characteristics《医疗电子加速器 第5部分 功能性能特征的稳定性试验》.pdf DIN 6847-5-2013 Medical electron accelerators - Part 5 Constancy tests of functional performance characteristics《医疗电子加速器 第5部分 功能性能特征的稳定性试验》.pdf
  • DIN 6847-6-2012 Medical electron accelerators - Part 6 Electronic portal imaging device(EPID) - Constancy testing《医用电子加速器 第6部分 电子射野影像装置(EPID) 仪器性能恒定性测试》.pdf DIN 6847-6-2012 Medical electron accelerators - Part 6 Electronic portal imaging device(EPID) - Constancy testing《医用电子加速器 第6部分 电子射野影像装置(EPID) 仪器性能恒定性测试》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1