1、3HUIRUPDQFH6SHFLILFDWLRQIRU8OWUDVRQLFDOO:HOGHG:LUH7HUPLQDWLRQVSAE/USCAR0D 2016ISBN: _ The research data, analysis, conclusion, opinions and other contents of this document are solely the product of the authors. Neither the SAE International (SAE) nor the United States Council for Automotive Research
2、 LLC (USCAR) certifies the compliance of any products with the requirements of nor makes any representations as to the accuracy of the contents of this document nor to its applicability for purpose. It is the sole responsibility of the user of this document to determine whether or not it is applicab
3、le for their purposes. Copyright 2016 USCAR Printed in U.S.A. All rights reserved. QUESTIONS REGARDING THIS DOCUMENT: (248) 273-2470 FAX (248) 273-2494 TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX (724) 776-0790 TABLE OF CONTENTS 1.0 SCOPE 4 1.1 Conformance Requirements . 5 1.2 Ultrasonic Weld Char
4、acteristics 5 2.0 REFERENCE DOCUMENTS 5 2.1 Normative References (Required to perform tests) 5 2.2 Informative References . 5 2.3 Test Request Documentation . 5 3.0 GENERAL REQUIREMENTS . 6 3.1 Record Retention 6 3.2 Sample Documentation . 6 3.3 Sample Size 6 3.4 Default Test Tolerances 6 3.5 Test D
5、efault Conditions . 6 3.6 Equipment . 6 3.7 Definitions and Abbreviations . 7 3.8 Measurement Resolution 7 3.9 Test Repeatability and Calibration 7 4.0 TEST PROCEDURES AND ACCEPTANCE CRITERIA 7 4.1 General Testing Requirements . 7 4.2 Visual Inspection . 8 4.3 Welded termination Cross-Section Analys
6、is . 13 4.4 Weld Bond Tensile and Peel Strength 15 4.5 Accelerated Environmental Exposure (Thermal Shock) Conditioning 18 4.6 Deleted (formerly vibration test) 18 4.7 Electrical Resistance Measurement (Dry Circuit and Voltage Drop) 19 4.8 Screening Test for Damage to weld bonds on the far end of a s
7、hort wire 21 5.0 VALIDATION REQUIREMENTS FOR WELDED WIRE/CABLE TERMINATION 22 5.1 Validation Requirements and Conformance Determination 22 5.2 Special Applications 23 5.3 Reference Validations . 23 APPENDIX A DEFINITIONS . 25 APPENDIX B ABBREVIATIONS . 27 APPENDIX C WELD DEVELOPMENT AND WELD GEOMETR
8、Y REFERENCE INFORMATION 28 APPENDIX D METHOD TO VALIDATE A RANGE OF PROCESS SETTINGS . 29 APPENDIX E QUALITY CONTROL TECHNIQUES . 30 APPENDIX F REVISION RECORD 31 SAE/USCAR-38 REVISION 1 Issued 2009-12 Revised 2016-05 PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS SAE/USCAR-38
9、 REVISION 1 Revised 2016-05 PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS - 4 - 1. SCOPE This specification defines test methods and performance criteria for evaluating ultrasonically welded wire-to-terminal metallurgical bonds. The examples used are specific to the linear we
10、ld type of process equipment. USCAR-38 is not apSOLFDEOHIRU6SOLFH:HOGLQJ The specification is applicable to wire-on-pad configurations with a typical weld shown in Figure 1. This test specification subjects parts under test to environmental exposures to simulate a lifetime of field exposure for a ro
11、ad vehicle. Exposures called-out in this specification include Thermal Shock, Temperature Humidity Cycling and mechanical abuse. This test specification is intended to evaluate the strength and performance of the interface between wires to an electrical terminal. Validation of the performance of the
12、 Terminal is a separate task and can be accomplished using a component validation test such as SAE/USCAR-2, which evaluates whether the entire connection system is acceptable. Figure 1 - Wire-to-pad weld configuration defined in USCAR-38 (USCAR-38 is not applicable for wire-to-wire splice welding) I
13、f the weld under test (WUT) is different than described in this section, or is subjected to conditions beyond what is typical of automotive use, the SAE/USCAR-38 test sequence may not be applicable. Parts used in custom applications must pass tests simulating the actual conditions encountered before
14、 they can be considered acceptable for that application. Vehicle and product conditions applicable to use of this specification are: 1) Applicable use: This specification is applicable where the wire and terminal are part of an electrical connection system used in road vehicles at ambient temperatur
15、es from -40C to +150C. Applied voltage may be either low (0 - 60 VDC) or high (to 600V). USCAR-38 applies to all wire lengths and includes a special test for wires shorter than 500mm where a weld is done after another component has been assembled to the wire (test samples must be made from the exact
16、 production-intent welding process to assess potential process damage risk to the terminal at the other end of the wire. Wire harness makers typically will be given the responsibility to track short wire applications per a statement in the applicable engineering statement of work. 2) Applicable desi
17、gns: The procedures described are applicable to buss, terminal, or device connections, including eyelet and battery terminations comprising either single or multiple wire terminations. Designs withd without crimped insulation wings are applicable. 3) Applicable wire: This specification was developed
18、 using clean, bare, uncoated, stranded automotive wire. Wire with tin coatings, applied lubricants, or contamination is known to affect the mechanical and electrical performance of ultrasonically welded cable terminations and are not applicable to be evaluated per this spec. 4) Applicable wire sizes
19、: Copper wire sizes between 0.22mm2 to 85mm2 per ISO 6722-1 wire specification and aluminum (per ISO 6722-2) sizes from 0.5mm2 to 120mm2 are applicable. Other wire types may be tested per this specification but cannot claim compliance to this specification since those sizes are out of our experience
20、. Examples of representative other wires types are: compressed core, compacted core, solid wire core, and wire core materials other than copper, copper alloy, aluminum, or aluminum alloy. Examples of different center core materials are copper-clad or steel-center-core wires. 5) The validation proces
21、s described applies only to linear ultrasonic welding, typically with pressure, energy, and amplitude set as inputs and weld time controlled by limiting energy EDVHGRQIHHGEDFNIURPSURFHVVPRQLWRULQJVHQ sors. Using process feedback assures the energy-per-weld is maintained. If the equipment used to mak
22、e samples for USCAR-38 testing is different from this description, this spec may need to be modified or may not be applicable. SAE/USCAR-38 REVISION 1 Revised 2016-05 PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS - 5 - 1.1 Conformance Requirements To claim conformance to this
23、 specification, the weld characteristics used to ultrasonically terminate a cable to a component must be traceable to a SAE/USCAR-38 test report where all tests per Table 5.1 meet the criteria of a good weld. The specific cable and component configuration (including stranding, actual cable cross sec
24、tional area, component base material and thickness as well as the tooling description) must be detailed in the report. The report must identify whether the short wire test per section 4.8 was or was not performed and the results. 1.2 Ultrasonic Weld Characteristics 1.2.1 Ultrasonically-welded termin
25、ation bond performance is characterized by: 1. Mechanical bond strength (measured by cable-to-component tensile and peel strength). 2. Electrical connection quality (measured by cable-to-component resistance or voltage drop). 3. Consistent weld attributes and parameters, characterized by:A. Weld bon
26、d height B. Weld bond width C. Weld bond length D. Insulation crimp height E. Insulation crimp width F. End of conductor limit G. End of insulation limit H. Wire prep (strip length and alignment) J. Strip length K. Weld position L. Terminal position and orientation M. Tooling profile or part number
27、N. Cable part number O. Number or cables being welded P. Terminal part number Q. Wire core material (plating on wire) R. Welder manufacturer and model S. Welder supplier part number for horn, anvil and gathering blocks, fixtureNOTE: The above are process and quality parameters. See Appendix C for a
28、related list of GHVLJQparameters recommended to be used to develop the correct tooling and process settings. 2. REFERENCE DOCUMENTS 2.1 Normative References (Required to perform tests) x SAE/USCAR-2: Performance Specification for Automotive Electrical Connector Systems (for initial validation) x SAE
29、/USCAR-21: Performance Specification for Cable-to-Terminal Electrical Crimps (for wire seal parts only) 2.2 Informative References x SAE J1128: Low Voltage Primary Cable x SAE J1127: Low Voltage Battery Cable x ISO/DIN 6722 Low Tension Primary Cable (Copper, Part 1 and Aluminum, Part 2) x AIAG Measu
30、rement Systems Analysis Reference Manual 2.3 Test Request Documentation The laboratory test request/order shall provide location and documentation of test samples, identify the type of test to be performed and describe any special tests that are not a part of this specification. Any revisions or dev
31、iations from any tests in this specification must include detailed instructions for each change. Note that sample groups with different weld dimensions need be tested per the method of Appendix D. Care must be taken to identify all samples correctly with the process settings used to weld them. Note
32、that the selection of the process settings to be tested are not controlled in this document; selection of settings is done prior to submitting samples for USCAR testing. No specific format for the report is required, as long as the required information is provided. Since some customers have requirem
33、ents for specific report formatting, it is recommended an agreement on report format is made before testing. SAE/USCAR-38 REVISION 1 Revised 2016-05 PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS - 6 - 3. GENERAL REQUIREMENTS 3.1 Record Retention The supplier shall maintain a
34、central file for the storage of laboratory reports and calibration records. Such record storage must be in accordance with established ISO and AIAG policies and practices. 3.2 Sample Documentation All test samples shall be identified in accordance with established (i.e. ISO or AIAG) policies and pra
35、ctices. 3.3 Sample Size Minimum sample sizes are given for each test in this specification. No part or device may be represented as having met this specification unless the minimum sample size has been tested and all samples of the group tested have met the applicable acceptance criteria for that te
36、st. It is never permissible to test a larger group then select the minimum sample size from among those that passed and represent that this specification has been met. 3.4 Default Test Tolerances Default tolerances, expressed as a percentage of the nominal value unless otherwise indicated, are shown
37、 in Table 3.4: Table 3.4 - Default test tolerances DESCRIPTION TOLERANCE Temperature 3C Voltage 5% Current 5% Resistance 5% Length 5% Time 5% Force 5% Relative Humidity 5% 3.5 Test Default Conditions When specific test conditions are not given either in the product design specification, the test req
38、uest/order or elsewhere in this specification, the following conditions apply: A. Room Temperature 23 5C B. Relative Humidity Ambient C. Voltage (DC) 14.0 0.1V 3.6 Equipment Table 3.6 highlights specialized equipment or devices with particular accuracy requirements used for USCAR-38 testing. Neither
39、 Table 3.6 nor the list in each test section is all-inclusive; items of customary laboratory equipment and supplies will also be required. Use of equipment with a lesser range is acceptable for specific tests where the required range for that test can be met. The equipment range specified does not p
40、reclude use of equipment with a larger range, but the accuracy must remain within the specified tolerance. SAE/USCAR-38 REVISION 1 Revised 2016-05 PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS - 7 - Table 3.6 - Equipment list DESCRIPTION REQUIREMENTS DC Power Supply (Regulate
41、d) 020V current sized as required Micro-Ohmmeter x 20 mV maximum open circuit voltage x 100 mA maximum test current x 0.01 m: resolution Digital Multimeter (DMM) Capable of measuring 0.001-50 Volts DC with accuracy of 0.5% of measurement Millivolt Meter Capable of measuring 0-100 mV DC with accuracy
42、 of 0.5 mV Thermocouples Type “J“ or “T“ as required (wire size .08mm) Force Tester Capable of an accuracy of 1% of measurement Thermal Shock Chamber -40 to 150C 3 (in 5 minutes or less) Oven (alternate to Thermal Shock Chamber) +150C 3 Temperature Chamber (alternate to Thermal Shock Chamber) -40 C
43、3 Video/photography equipment As required to make clear pictures, including Cross-section micrographs 3.7 Definitions and Abbreviations Terms defined in the definitions or glossary are capitalized (i.e. Room Temperature, Steady State, etc.). A list of def-initions is in Appendix A. Abbreviations are
44、 in Appendix B. 3.8 Measurement Resolution Unless otherwise specified, meters and gages used in measurements of the test sample(s) shall be capable of measuring with a resolution one decimal place better than the specified value. For example, even though a wire diameter specified as 0.1 mm might act
45、ually be the same as one specified as 0.10 mm, calipers capable of 0.01 mm resolution may be used to measure the first wire but a micrometer with 0.001 mm resolution is required to measure the second wire. 3.9 Test Repeatability and Calibration All equipment used for testing shall be calibrated and
46、maintained aORQJZLWKSHULRGLFJDJH5 5VLQDFFRUGDQFHZLWKLQGLYLGXDOWHVWIDFLOLWFHUWLILFDWLRQUHTXLUHPHQWVDQGDSSOLFDEOHVWDQGDUGV7KH$,$*SXEOLFDWLRQ0HDVXUHPHQW6VWHPV$QDOVLV5HIHUHQFH0DQXDOFDQEHXVHGDVDJXLGHOLQH$OLVWRILQVWUXPHQWVDQGHTXLSP ent used for the USCAR test, date of the last calibration, and when the ne
47、xt calibration is due is to be included in each USCAR test report. 4. TEST PROCEDURES AND ACCEPTANCE CRITERIA 4.1 General Testing Requirements The test procedures in this section are stand-alone tests and may be used as such. However, they are normally used as a sequential test. Knowledge of test group construction is required to overcome any redundancies in sample preparation or procedures. For example, if samples have already been prepared for the preceding test in