资源描述

1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21168-4 SANS 1510-1:2008Edition 1.1Any reference to SABS 1510-1 is deemedto be a reference to this standard(Government Notice No. 1373 of

4、8 November 2002)SOUTH AFRICAN NATIONAL STANDARD Door closers Part 1: Single-action overhead door closers Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Afr

5、ica SANS 1510-1:2008 Edition 1.1 Table of changes Change No. Date Scope Amdt 1 2008 Amended to change the designation of SABS standards to SANS standards and to update referenced standards. Foreword This South African standard was approved by National Committee StanSA SC 5120.14E, Security Automatic

6、 doors closers, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This document was published in May 2008. This document supersedes SABS 1510-1:1990 (edition 1). A vertical line in the margin shows where the text has been technically modifi

7、ed by amendment No. 1. SANS 1510-1:2008 Edition 1.1 1 Contents Page Foreword 1 Scope . 3 2 Definitions 3 3 Requirements . 4 4 Packing and marking . 5 5 Inspection and methods of test 6 5.1 Inspection . 6 5.2 Preparation for testing 6 5.3 Test apparatus . 7 5.4 Conditioning . 8 5.5 Sequence of testin

8、g . 8 5.6 Test for closing moment . 8 5.7 Test for closing time . 9 5.8 Test for opening moment . 9 5.9 Test for latching action . 9 5.10 Test for backcheck stop position 9 5.11 Test for durability 9 Appendix A Applicable standards 10 Appendix B Notes to purchasers . 10 Appendix C Quality verificati

9、on of door closers . 10 SANS 1510-1:2008 Edition 1.1 2 This page is intentionally left blank SANS 1510-1:2008 Edition 1.1 3 Door closers Part 1: Single-action overhead door closers 1 Scope 1.1 This part of the specification covers the requirements for the mechanical performance of single-action over

10、head door closers of six sizes (with or without backcheck action and with or without delayed action), including their operating arms and arm linkages but excluding the pivotal or hinging arrangement of the door. It covers door closers that are intended for face fixing either on the door or on the tr

11、ansom and that automatically close hinged and pivoted doors in a controlled manner. 1.2 This part of the specification does not cover requirements specific to door closers for fire doors. NOTE a) The standards referred to in the specification are listed in appendix A. b) A requirement that must be s

12、pecified by the purchaser is given in appendix B. c) Guidance on the verification of the quality of single-action overhead door closers is given in appendix C. 2 Definitions 2.1 For the purposes of this specification the following definitions shall apply: backcheck action a cushioning or damping act

13、ion that comes into effect when a door is opened rapidly towards the fully open position delayed action a function that delays or slows the closing action when the door is opened beyond a specified angle latching action a reduction of the damping action of a door closer in the final stage of the clo

14、sing cycle, such that the full force of the closing spring is available to operate any latch on the door variable-size door closer a door closer that can, by means of adjustment, perform the duty of two or more sizes of door closers SANS 1510-1:2008 Edition 1.1 4 3 Requirements 3.1 Size A door close

15、r shall be of one of the sizes given in column 1 of table 1, as required. 3.2 Opening angle The maximum opening angle permitted by a door closer shall be as specified by the manufacturer, but not less than 115. Table 1 Sizes of door closers 1 2 3 4 5 Max. door leaf width Max. door height Max. door m

16、ass Max. distance of centre of gravity of door from vertical axis of hinges Size of door closermm mm kg mm 1 2 3 760 813 915 2 032 2 032 2 100 30 45 60 365 365 442 4 5 6 1 050 1 250 1 400 2 150 2 250 2 440 80 110 150 510 610 685 3.3 Closing moment When a door closer is tested in accordance with 5.6,

17、 the closing moment measured shall be at least equal to the appropriate values given in columns 2 and 3 of table 2. Table 2 Closing moment 1 2 3 Minimum closing momentNm Size of door closerAt 2 open At 90 open1 2 3 8 10 17 2,0 2,5 5 4 5 6 27 37 48 9 13 17 3.4 Closing time The time that a door closer

18、 takes to return the door from 90 open to the closed position shall be capable of being adjusted and, when determined in accordance with 5.7, shall exceed 10 s. SANS 1510-1:2008 Edition 1.1 5 3.5 Opening moment When a door closer is tested in accordance with 5.8, the opening moment shall not exceed

19、the appropriate value given in column 2 of table 3. Table 3 Opening moment 1 2 Max. opening moment Size of door closerNm 1 2 3 22 30 41 4 5 6 54 74 96 3.6 Latching action range A door closer shall have a latching action and, when a door closer is tested in accordance with 5.9, the latching action sh

20、all commence to operate at a position not less than 30 mm (approximately 2) and not more than 280 mm (approximately 22) from the closed position (measured at a point 700 mm from the hinge axis). 3.7 Backcheck stop position When tested in accordance with 5.10, a door closer provided with a backcheck

21、action shall arrest the door within 5 of the opening angle (specified by the manufacturer) at which the backcheck action commences. 3.8 Delayed action If a door closer is provided with a delayed action, the closing action shall operate as specified by the manufacturer, both before and after the dura

22、bility test given in 5.11. 3.9 Durability When a door closer is tested for 500 000 cycles in accordance with 5.11, neither the closer nor its operating arms and arm linkages shall show any visible sign of damage, there shall be no leakage of fluid, and the closer shall still comply with the requirem

23、ents of 3.3-3.8 (inclusive). 4 Packing and marking 4.1 Packing 4.1.1 Fastenings Each door closer shall be supplied complete with all screws, bolts or other fastenings necessary for proper fixing to either timber, aluminium or steel doors and frames. SANS 1510-1:2008 Edition 1.1 6 4.1.2 Tools Each do

24、or closer shall be supplied with the special tools necessary for its installation and adjustment. 4.1.3 Instructions Each door closer shall be supplied with clear and detailed instructions for its installation and adjustment, and with fixing templates. Information shall be included on the relationsh

25、ip between size, arm configuration and suitability of the door closer for internal or external doors (or both). The angle across which the door closer operates shall be clearly stated. 4.2 Marking Each door closer shall bear the following information in legible and indelible marking: a) the manufact

26、urers name, trade name or trade mark; b) the size of the door closer. 5 Inspection and methods of test 5.1 Inspection Visually examine and measure the door closers in the sample for compliance with all the requirements of the specification for which tests to assess compliance are not given in 5.6-5.

27、11 (inclusive). 5.2 Preparation for testing 5.2.1 Test door and frame A test door of the appropriate dimensions and mass as specified in columns 2, 3 and 4 of table 1, mounted on hinges or bearings attached to a rigid frame and such that a) the centre of gravity of the test door is at the intersecti

28、on of a horizontal line midway between the hinges and a vertical line at a distance from the vertical axis of the hinges as given in column 5 of table 1; NOTE If the mass of the door is less than that given in column 4 of table 1, the mass may be increased with a steel plate in such a manner that th

29、e centre of gravity is as required. b) the moment required to open the door does not exceed 1 Nm. The moment is determined by measuring the maximum force (in newtons) required to open and close the door slowly, with the force applied perpendicular to the door face and at a position 700 mm from the v

30、ertical axis of the hinges; c) an eye bolt (or other suitable means of attachment for a cable) is provided, 50 mm from the lockside of the door, on a horizontal line midway between the hinges, on the opening face of the door. 5.2.2 Procedure a) Mount the door closer under test on the test door and f

31、rame, in accordance with the manufacturers instructions, using the screws or bolts supplied. SANS 1510-1:2008 Edition 1.1 7 b) With the closer mounted on the test door, open the door by hand to approximately 180 or to the maximum opening angle specified by the manufacturer, whichever is the lesser,

32、and allow the door closer to return the door to the closed position. Repeat this four times (i.e. to a total of five times) in order to ensure that the mounting and operation of the door and closer are satisfactory. NOTE If variable-size door closers are to be tested, test two door closers, one set

33、at the minimum size and the other at the maximum size claimed for that door closer. 5.3 Test apparatus 5.3.1 Cycling mechanism A cycling mechanism that a) is capable of smoothly opening the door from the closed position to the fully open position within a period of 5-7 s; b) provides the facility to

34、 set the dwell time between successive opening/closing cycles to a minimum of 3 s and a maxi mum of 10 s; c) has a counter to record the number of cycles; d) neither impedes nor assists the return of the test door from the fully open position to the closed position. 5.3.2 Abuse apparatus An abuse ap

35、paratus that a) consists of a system of pulleys with a steel cable of nominal diameter 6 mm and a masspiece so arranged that, when the door is closed, the cable attached to the eye-bolt forms an included angle of 45 between the cable and the door; b) has a means by which the test door can be suddenl

36、y released from its closed position; c) has a means of so arresting the masspiece when the test door reaches the 75 open position that further opening of the door is not impeded; d) has an energy-absorbent stop to prevent the door from opening beyond 95. NOTE The masspiece shall be of mass equal to

37、that given in column 2 of table 4. Table 4 Abuse apparatus masspiece 1 2 Size of masspiece Size of door closerkg 1 2 3 12,5 15 17,5 4 5 6 20 22,5 25 SANS 1510-1:2008 Edition 1.1 8 5.4 Conditioning Before carrying out the tests, condition the door closer, mounted on the test door and frame, as follow

38、s: a) Carry out 4 000 opening/closing cycles, ensuring that any backcheck or delayed or hold-open action is disabled or adjusted to the minimum resistance during cycling. b) Using the abuse apparatus, subject the closer to four cycles of abuse, as follows: 1) Hold the door in the closed position; 2)

39、 suddenly release the door and allow the masspiece to pull the door open until it is stopped by the closer. c) If necessary, re-adjust the door closer in accordance with the manufacturers instructions. 5.5 Sequence of testing After conditioning the door closer in accordance with 5.4, carry out the t

40、ests given in 5.6-5.10 (inclusive) followed by the test for durability given in 5.11. Then repeat the tests given in 5.6-5.10 (inclusive). NOTE a) If a door closer is supplied together with instructions for various mounting arrangements to provide different maximum opening angles, carry out the init

41、ial and final series of tests using each mounting arrangement in turn, but carry out the durability test using the arrangement that provides the greatest maximum opening angle. b) The angles specified by the manufacturer for commencement of various actions (e.g. the backcheck action), may vary for d

42、ifferent mounting arrangements. 5.6 Test for closing moment 5.6.1 Apparatus A force gauge or other suitable means of measuring the horizontal force exerted by the door owing to the closer. 5.6.2 Procedure a) Open the door to the 95 open position. Allow the door to close very slowly against the force

43、 gauge so positioned perpendicular to the face of the door and at a horizontal distance of 700 mm from the vertical axis of the hinges that the door will be stopped at 90 from the closed position. Record the gauge reading. b) Repeat (a) above with the force gauge so positioned that the door will be

44、stopped at 2 from the closed position, and record the gauge reading. c) Calculate the closing moment in each case as the force times 0,7 m, and check for compliance with 3.3. SANS 1510-1:2008 Edition 1.1 9 5.7 Test for closing time a) Set the adjustment for closing speed to its slowest setting. b) O

45、pen the door by hand to the 90 open position and allow the door closer to return the door to the closed position. c) Measure the time required for this action and check for compliance with 3.4. 5.8 Test for opening moment 5.8.1 Apparatus A force gauge or other suitable means of measuring the horizon

46、tal force necessary to open the door. 5.8.2 Procedure Use the force gauge, positioned at a point 700 mm from the vertical axis of the hinges, to push the door open very slowly, and record the highest gauge reading between 15 mm and 75 mm opening of the door, and check for compliance with 3.5. 5.9 Te

47、st for latching action Open the door to the fully open position and allow the door closer to return the door to the closed position. Note the door position at which the latching action commences and check for compliance with 3.6. 5.10 Test for backcheck stop position a) With the abuse test apparatus

48、 attached to the test door (and the backcheck action (if relevant) adjusted to maximum resistance), hold the door in the closed position. b) Suddenly release the door, and allow the masspiece to pull the door open until it is stopped by the closer. c) Note the position at which the door stops and ch

49、eck for compliance with 3.7. 5.11 Test for durability 5.11.1 Procedure NOTE Ensure that any backcheck action or delayed or hold-open action is disabled or adjusted to the minimum resistance during cycling. a) Using the cycling mechanism, carry out 500 000 opening/closing cycles of the test door. b) After each 50 000 cycles, stop the cycling mechanism, set the backcheck and carry out four cycles of abuse as described in 5.4(b) and (c), leaving the cycling mechanism switched off for at least 12 h. c) Examine the door closer, the operating arms and arm linkage